Lochinvar · Noble Fire Tube (NKB/NKC/NCF)
Lochinvar Noble NKC110
The Noble NKC110 is the entry Noble wall-hung combi: 11 to 110 MBH input at 95.0% AFUE, rated for DHW of up to 2.6 GPM at a 77°F rise, with 3/4" DHW connections.
Key figures
- Max input
- 110 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 11 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Lochinvar Noble NKC110 in practice
The NKC110 is the smallest Noble combi and the wall-hung member of the Noble ratings row it shares with the NKB110 and NCF110: 11 to 110 MBH of space-heating input with 102 MBH of DOE capacity at 95.0% AFUE. Its product page quotes domestic hot water of up to 2.6 GPM at a 77°F temperature rise, with 3/4" DHW connections and 1" NPT space-heating connections on the combi.
Lochinvar's combi copy describes the SMART CONTROL's patent-pending control technology as eliminating the cold-water "sandwich" between DHW draws, and the same page lists an air-handler interlock that prevents cool air circulation while the appliance makes hot water. Sold as Epic in Canada per Lochinvar's residential page, the NKC110 holds 1.4 gallons, vents in 2" or 3" pipe to 100 equivalent feet, and carries a 10-year heat exchanger and 5-year parts warranty on the product page.
Best suited to
- Homes that want on-demand hot water without a separate tank
- Wall-hung installations whose heat loss fits under 110 MBH
- Households with modest DHW demand that the 2.6 GPM (77°F rise) rating serves
Applicability and support
- Model number
- NKC110L
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Heating input, minimum | 11 MBH | Per the I&O ratings table. |
| Heating input, maximum | 110 MBH | Per the I&O ratings table. |
| Output | ||
| DOE heating capacity | 102 MBH | DOE heating capacity per the I&O ratings table. |
| AHRI net water rating | 89 MBH | Net AHRI rating based on a piping and pickup allowance of 1.15. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95.0% AFUE per the I&O ratings table. |
| Domestic hot water | ||
| DHW flow at 77°F rise | 2.6 GPM | Up to 2.6 GPM, per the product page for the NKC110. |
| Domestic hot water | On demand from the combi's DHW circuit | Combi models produce DHW directly; the I&O ratings list 3/4" DHW water connections for combi units. |
| Venting and air | ||
| Venting | Category IV sealed combustion; PVC, CPVC, polypropylene or stainless steel | In Canada, plastic venting must be a ULC S636-certified system. |
| Max. equivalent vent/air length, 2" | 100 ft | Table 3D (air intake/vent piping sizes), I&O manual. |
| Max. equivalent vent/air length, 3" | 100 ft | Table 3D (air intake/vent piping sizes), I&O manual. |
| Physical and connections | ||
| Water content | 1.4 gal | Per the I&O ratings table. |
| Space-heating water connections | 1" NPT | Noble ratings: NPT connections are used on combi units, sweat connections on the boiler. |
| DHW water connections | 3/4" | Combi-only, per the I&O ratings table (NPT = combi). |
| Gas connection | 1/2" | Per the I&O ratings table. |
| Shipping weight | 153 lb | Shipping weight per the Lochinvar product page. |
| Height | 44.25 in | Wall-mounted combi cabinet, per the Lochinvar product page. |
| Width | 17.25 in | Wall-mounted combi cabinet, per the Lochinvar product page. |
Manuals
Alerts documented for this model
- Memory Error
- Fan Speed
- LWCO
- Flame Sequence
- Outlet ARHL
- Air Pressure Switch
- AUX Limit Fault
- Flame Fail: Running
- Flame Fail: Ignition
- Flue Temp Limit
- Flue Temp High
- Outlet MRHL
- Outlet Temp High
- Outlet Temp DIFF
- Flue Sensor Fault
- Outlet Sensor Fault
- Inlet Sensor Fault
- Set Point Met
- Anti-Cycling
- Delta T High
- Low Voltage
- No Flue Temp Change
- Combi Sensor Fault (Combi Only)
- Lockout Inlet Sensor Fault
- Outdoor Sensor Missing
- No Hot Water at Faucets (Combi Only)
- DHW Water is not Hot Enough (Combi Only)
- Combi Boiler is Running but Does Not Supply Heated Water to Space Heating System (Combi Only)
- Space Heating System Heat Emitters Get Hot During a DHW Draw and the Combi Boiler does not Provide Hot Enough Domestic Hot Water (Combi Only)
- Lockout! Water Press Switch
Frequently asked questions
How much hot water can the NKC110 deliver?
The product page quotes DHW of up to 2.6 GPM at a 77°F temperature rise, and Lochinvar's combi copy describes DHW of up to 4.8 GPM. Delivery depends on input and incoming water temperature.
Is the NKC110 a boiler or a combi?
It is the wall-mount combi: one appliance provides space heating and on-demand domestic hot water through its 3/4" DHW connections, so no separate hot-water tank is required.
Questions about the Lochinvar Noble NKC110?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- Lochinvar Noble NKC110 vs NKC150Comparison
- Lochinvar Noble NKB080Same series
- Lochinvar Noble NKB110Same series
- Lochinvar Noble NKB150Same series
- Lochinvar Noble NKB199Same series
- Lochinvar Noble NKC150Same series
- Lochinvar Noble NKC199Same series
- Lochinvar Noble NCF110Same series
- Lochinvar Noble NCF150Same series
- Lochinvar Noble NCF199Same series
- Noble Fire Tube (NKB/NKC/NCF) series hub
- Buying guide
Sources and verification
- Lochinvar — Noble Combi Gas Boiler Wall Mount (NKC110L) model page · accessed September 7, 2026
- Noble Fire Tube Boiler and Combi I&O/Service Manual, Rev AN · Rev AN · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.