Navien NCB-250/150H vs NTI Trinity TRX150C

Verdict in brief

The Navien NCB-250/150H and NTI Trinity TRX150C are both 95% AFUE combis, but the model numbers hide the real gap: NTI lists the TRX150C's heating input at 13.2 to 120 MBH while Navien rates the NCB-250/150H to 150 MBH for heating, and Navien draws up to 210 MBH for DHW against the NTI's 3.5 GPM continuous rating at a 77°F rise. Heating load first, then hot-water draw.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Navien NCB-250/150H and NTI Trinity TRX150C
SpecificationNavien NCB-250/150HNTI Trinity TRX150C
Heating input, minimum14 MBH13.2 MBH
Heating input, maximum150 MBH120 MBH
Efficiency (AFUE)95 %95 %
FuelNatural gas or propaneNatural gas or propane
Weight96 lb92.8 lb
Max. equivalent vent length, 2"65 ft100 ft
Max. equivalent vent length, 3"150 ft150 ft
Gas connection3/4" NPT3/4" NPT
Heating water connections1" NPT1" male sweat with adapter
Domestic hot waterIntegrated in the combi heat exchangerIntegrated combi (DHW plate) in the appliance

What actually separates them

Both are wall-hung combis rated 95% AFUE on natural gas or propane, yet their heating envelopes are not the equal class the names suggest. Navien publishes 14 to 150 MBH of heating input for the NCB-250/150H, while NTI's records list the TRX150C at 13.2 to 120 MBH — a 30 MBH gap at the top that decides large homes, even though the TRX fires slightly lower at its minimum.

The DHW sides use different yardsticks again: Navien documents DHW input of 14 to 210 MBH for the 150H model, while NTI publishes 3.5 GPM continuous DHW delivery at a 77°F rise for the TRX150C. Both approaches are legitimate, but a buyer comparing them must translate one brand's input figure and the other's flow figure against the same household draw before concluding which combi is adequate.

Physically the two are close: the NCB-250/150H weighs 96 lb with 1" NPT heating connections and 2" venting to 65 feet or 3" to 150 feet per side, while the TRX150C weighs 92.8 lb with 1" male sweat heating connections (adapters included) and 2" venting to 100 feet or 3" to 150 feet per side. A heat-loss calculation plus a fixture-by-fixture hot-water check selects between the 150 MBH Navien and the 120 MBH-ceiling NTI.

CurrentSold in Canada
Input
14–150 MBH
Output (max)
—
AFUE
95 %

The Navien NCB-250/150H is the largest NCB-H combi: 14 to 150 MBH heating input with DHW input from 14,000 to 210,000 BTU/h, rated 95.0% AFUE in the same 96 lb, 17.3-inch-wide cabinet as the 240-class models.

Natural gasPropaneCombi
CurrentSold in Canada
Input
13.2–120 MBH
Output (max)
—
AFUE
95 %

The NTI Trinity TRX150C is the mid-size TRX combi: space heating at 13.2 to 120 MBH input and 3.5 GPM continuous DHW at a 77°F rise, rated 95% AFUE in a 92.8 lb wall-hung boiler.

Natural gasPropaneCombi

Frequently asked questions

Which combi heats to a higher input?

The Navien NCB-250/150H reaches 150 MBH of heating input, while NTI lists the TRX150C at 120 MBH maximum despite its 150C name.

How do the DHW ratings differ?

Navien documents DHW input up to 210 MBH on the NCB-250/150H, while NTI documents 3.5 GPM continuous delivery at a 77°F rise on the TRX150C.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.