Navien NCB-250/150H
The Navien NCB-250/150H is the largest NCB-H combi: 14 to 150 MBH heating input with DHW input from 14,000 to 210,000 BTU/h, rated 95.0% AFUE in the same 96 lb, 17.3-inch-wide cabinet as the 240-class models.
Key figures
- Max input
- 150 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 14 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Navien NCB-250/150H in practice
The NCB-250/150H tops the NCB-H line at 150 MBH of heating input — the ceiling for the series — while its DHW side fires the highest of any NCB-H model, from 14,000 to 210,000 BTU/h. The 250-class combi is the candidate for large detached homes and households with big or frequent hot-water draws where the smaller models would run out of DHW headroom.
It keeps the NCB-H cabinet at 17.3 x 29.3 x 12.8 in and 96 lb, with 95.0% AFUE, 1" NPT heating connections and 2" or 3" venting to 65 or 150 equivalent feet. Its 14 MBH minimum fire is the highest in the NCB-H line, so a heat-loss calculation should confirm the load actually needs the 150 MBH ceiling before this size is chosen.
Best suited to
- Large detached homes whose heat-loss calculation approaches 150 MBH
- Households with the highest DHW demand in the NCB-H line (DHW input to 210,000 BTU/h)
- One-appliance replacements for an older boiler plus tank where both loads are large
Applicability and support
- Model number
- NCB-250/150H
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Navien. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Heating input, minimum | 14 MBH | Space-heating input. |
| Heating input, maximum | 150 MBH | Space-heating input. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95.0% AFUE per the installation manual. |
| Domestic hot water | ||
| DHW input, minimum | 14 MBH | 14,000 BTU/h |
| DHW input, maximum | 210 MBH | 210,000 BTU/h |
| Domestic hot water | Integrated in the combi heat exchanger | |
| Venting and air | ||
| Venting | PVC, CPVC or approved polypropylene; 2" or 3" | Canada: plastic venting must meet ULC S636 where required. |
| Max. equivalent vent length, 2" | 65 ft | |
| Max. equivalent vent length, 3" | 150 ft | |
| Physical and connections | ||
| Weight | 96 lb | Empty; per the installation manual. |
| Width | 17.3 in | |
| Height | 29.3 in | |
| Depth | 12.8 in | |
| Gas connection | 3/4" NPT | |
| Heating water connections | 1" NPT | |
| Operating limits and other | ||
| Fuel | Natural gas or propane | Separate Navien ratings per fuel. |
| Altitude rating | 10,100 ft | Per installation manual. |
| System water pressure | 12 – 30 psi | |
Manuals
Alerts documented for this model
Frequently asked questions
What makes the NCB-250/150H different from the 240-class NCB-H models?
Heating input rises to 14,000 to 150,000 BTU/h and DHW input to 14,000 to 210,000 BTU/h, both the highest figures in the series. Weight and cabinet match the 240-class models.
Is the NCB-250/150H too big for an average house?
Possibly. Its 14 MBH minimum fire is the highest in the NCB-H line, so in a low-load home the boiler would cycle more in mild weather. A heat-loss calculation, not floor area, decides whether 150 MBH of ceiling is justified.
Does the NCB-250/150H come with the same warranty as the rest of the series?
Navien Canada's published NCB-H terms — 10-year heat exchanger, 5-year parts, 1-year labour per the quick facts — cover the series, and registration conditions are confirmed with Navien Canada.
Questions about the Navien NCB-250/150H?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- Navien NCB-240/130H vs NCB-250/150HComparison
- Navien NCB-250/150H vs NTI Trinity TRX150CComparison
- Navien NCB-250/150H vs Rinnai IP150199CComparison
- Navien NCB-190/060HSame series
- Navien NCB-190/080HSame series
- Navien NCB-240/110HSame series
- Navien NCB-240/130HSame series
- NCB-H Combi series hub
- Buying guide
Sources and verification
- Navien Canada — NCB-H series · accessed September 7, 2026
- NCB-H Installation and Operation Manual (EN) · accessed September 7, 2026
- NCB-H Service Manual, Ver 1.00 (Feb 2021) · Ver 1.00 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.