Navien NCB-250/150H vs Rinnai IP150199C

Verdict in brief

The Navien NCB-250/150H and Rinnai IP150199C are both 95% AFUE-class wall-hung combis with a 150 MBH heating side and a 199-210 MBH DHW side, but their DHW reach is stated differently: Rinnai publishes 9.8 GPM maximum flow (5.1 GPM at a 70°F rise) while Navien lists DHW input to 210 MBH. Rinnai is lighter at 76.1 lb with a 160-foot 3" vent limit; Navien weighs 96 lb. Heat loss and shower load decide.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Navien NCB-250/150H and Rinnai IP150199C
SpecificationNavien NCB-250/150HRinnai IP150199C
Heating input, minimum14 MBH15 MBH
Heating input, maximum150 MBH150 MBH
DHW input, maximum210 MBH199 MBH
Efficiency (AFUE)95 %96 %
FuelNatural gas or propaneNatural gas or propane
Weight96 lb76.1 lb
Width17.3 in18.5 in (470 mm)
Depth12.8 in11.5 in (291 mm)
VentingPVC, CPVC or approved polypropylene; 2" or 3"2" nominal PVC/polypropylene or 3" x 5" concentric
Max. equivalent vent length, 2"65 ft75 ft
Max. equivalent vent length, 3"150 ft160 ft
System water pressure12 – 30 psi13 – 45 psi
Gas connection3/4" NPT3/4" NPT
Heating water connections1" NPT1" NPT
Domestic hot waterIntegrated in the combi heat exchangerOn demand inside the combi

What actually separates them

Both are wall-hung combis whose heating input lands at 150 MBH — Navien lists 14 to 150 MBH for the NCB-250/150H and Rinnai lists 15 to 150 MBH for the IP150199C — with AFUE figures of 95.0% (Navien) and up to 96% per Rinnai's marketing copy. Minimum fires are nearly level at 14 versus 15 MBH, so part-load behaviour in an average detached home is similar on paper.

Hot water is documented in different currencies. Navien publishes DHW input from 14 to 210 MBH, while Rinnai publishes a 199 MBH maximum DHW input, a 9.8 GPM maximum DHW flow, and 5.1 GPM at a 70°F rise. The Rinnai's flow figures are directly usable for a fixture count; the Navien's input figure must be converted against temperature rise and draw pattern to reach the same comparison.

Weight and venting complete the picture: the IP150199C weighs 76.1 lb per its I&O manual (the Rinnai page prints 62 lb, a documented discrepancy) and vents 2" to 75 feet or 3" to 160 feet, while the NCB-250/150H weighs 96 lb and vents 2" to 65 feet or 3" to 150 feet. Both use 3/4" NPT gas and 1" NPT heating connections, and both are sized by heat-loss calculation plus the home's peak hot-water demand.

CurrentSold in Canada
Input
14–150 MBH
Output (max)
—
AFUE
95 %

The Navien NCB-250/150H is the largest NCB-H combi: 14 to 150 MBH heating input with DHW input from 14,000 to 210,000 BTU/h, rated 95.0% AFUE in the same 96 lb, 17.3-inch-wide cabinet as the 240-class models.

Natural gasPropaneCombi
CurrentSold in Canada
Input
15–150 MBH
Output (max)
—
AFUE
96 %

The Rinnai IP150199C is the top of the fully documented I-Series+ combi range: 15 to 150 MBH central-heating input with a 199 MBH DHW side (9.8 GPM maximum), the largest small-chassis combi at 76.1 lb.

Natural gasPropaneCombi

Frequently asked questions

Which combi is rated for more hot water?

Rinnai publishes 9.8 GPM maximum DHW flow (5.1 GPM at a 70°F rise) for the IP150199C, while Navien documents the NCB-250/150H's DHW input up to 210 MBH without a GPM maximum figure.

How much do these combis weigh?

Rinnai lists 76.1 lb for the IP150199C in its manual (62 lb on the product page) versus 96 lb for the Navien NCB-250/150H.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.