NTI Trinity TFTN199
The NTI Trinity TFTN199 is the 95% AFUE wall-hung TFTN at the classic 199 MBH mark: 19.9 to 199 MBH input, 140 lb with water, still on 1 1/4" NPT CH connections with 2" venting to 100 ft or 3" to 150 ft.
Key figures
- Max input
- 199 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 19.9 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
NTI Trinity TFTN199 in practice
The TFTN199 is the largest wall-hung TFTN that keeps the family's compact cabinet shape — 19 7/8 by 34 1/8 by 18 3/4 inches — while carrying 140 lb with water and a 199 MBH input ceiling on 1 1/4" NPT CH connections. It is heating-only and rated 95% AFUE, with the touchscreen, Wi-Fi and built-in low-water cut-off shared across the wall line.
For a BC house this is the size to reach for when the heat-loss calculation plus indirect-tank recovery genuinely approaches 199 MBH — large homes, or houses adding a big tank with fast recovery. Its 19.9 MBH minimum fire is the reason not to oversize: below that calculated load, the TFTN150 keeps more steady condensing hours in mild weather.
Best suited to
- Large homes whose heat-loss and recovery loads approach 199 MBH
- Small multi-suite buildings where one wall-hung unit is appropriate
- Projects wanting 199 MBH without moving to the wider 285 chassis
Applicability and support
- Model number
- TFTN199
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum | 19.9 MBH | Per the NTI product page. |
| Input, maximum | 199 MBH | Per the NTI product page. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | Per the NTI product page. |
| Domestic hot water | ||
| Domestic hot water | Heating-only; pair with an indirect tank or separate water heater | |
| Venting and air | ||
| Max. equivalent vent length, 2" | 100 ft | 2" pipe; up to 100 ft each per the NTI product page. |
| Max. equivalent vent length | 150 ft | 3" pipe; up to 150 ft each per the NTI product page. |
| Physical and connections | ||
| Weight | 140 lb | With water, per the NTI product page. |
| CH water connections | 1 1/4" NPT | Male NPT per the NTI product page. |
| Gas connection | 3/4" NPT | Male NPT per the NTI product page. |
| Width | 19.875 in | Per the TFTN I&O manual, Table 2-1. |
| Height | 34.125 in | Per the TFTN I&O manual, Table 2-1. |
| Depth | 18.75 in | Per the TFTN I&O manual, Table 2-1. |
| Operating limits and other | ||
| Fuel | Natural gas or propane | NTI publishes LP conversion instructions for this series. |
Manuals
- TFTN 085–399 I&O Manual, 99987137, V.2025-04-24 (HMI R30)99987137 · 2025-04-24
- TFTN 500–850 I&O Manual, 99987545, V.2025-04-2499987545 · 2025-04-24
Alerts documented for this model
- 101 1
- 102
- 103 1
- 104 1
- 105 1
- 106 1
- 109
- 110 1
- 112 1
- 113
- 114
- 115
- 117 1
- 118 1
- 150
- 1P1 1
- 1P2 1
- 1P3 1
- 1P4
- 203
- 209
- 2P2
- 303
- 304
- 306
- 309
- 3P9
- 411
- 412
- 413
- 441
- 460
- 501 1
- 502
- 504 1
- 5P1
- 5P2
- 5P6
- 5P3
- 5P5
- 602
- 603 1
- 605
- 608
- 612 1
- 730
- Unconfigured
- Conflict
- 101 1
- 102
- 103 1
- 104 1
- 105 1
- 106 1
- 109
- 110 1
- 112 1
- 113
- 114
- 115
- 117 1
- 118 1
- 150
- 1P1 1
- 1P2 1
- 1P3 1
- 1P4
- 203
- 209
- 2P2
- 303
- 304
- 306
- 309
- 3P9
- 411/412/413
- 441
- 460
- 501 1
- 502
- 504 1
- 5P1
- 5P2
- 5P6
- 5P3
- 5P5
- 602
- 603 1
- 605
- 608
- 612 1
- 730
- Unconfigured
- Conflict
Frequently asked questions
Does the TFTN199 fit the compact TFTN cabinet?
Yes. It measures 19 7/8 by 34 1/8 by 18 3/4 inches at 140 lb with water — the same width and height as the 085 through 150 models.
What is the TFTN199's efficiency?
95% AFUE per the NTI product page; within the wall line only the TFTN085 (96%) rates higher.
Can the TFTN199 be vented in 2" pipe?
Yes — NTI lists 2" to 100 ft and 3" to 150 ft per side for the 199, with no bulletin restriction printed on the TFTN page (unlike the FTVN and TRX 199 models).
Questions about the NTI Trinity TFTN199?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- NTI Trinity TFTN150 vs TFTN199Comparison
- NTI Trinity TFTN199 vs TFTN285Comparison
- IBC SL 30-199 G3 vs NTI Trinity TFTN199Comparison
- Navien NFB-200H vs NTI Trinity TFTN199Comparison
- NTI Trinity TFTN085Same series
- NTI Trinity TFTN110Same series
- NTI Trinity TFTN150Same series
- NTI Trinity TFTN285Same series
- NTI Trinity TFTN340Same series
- NTI Trinity TFTN399Same series
- NTI Trinity TFTN500Same series
- NTI Trinity TFTN600Same series
- NTI Trinity TFTN725Same series
- NTI Trinity TFTN850Same series
- Trinity TFTN series hub
- Buying guide
Sources and verification
- NTI — TFTN Series product page · accessed September 7, 2026
- TFTN 085–399 I&O Manual, 99987137, V.2025-04-24 (HMI R30) · 99987137 · accessed September 7, 2026
- TFTN 500–850 I&O Manual, 99987545, V.2025-04-24 · 99987545 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.