New Yorker GHE-II GHE2-080 vs GHE2-150

Verdict in brief

The GHE2-080 and GHE2-150 are both 95.0% AFUE GHE-II condensing boilers on a 2-inch direct-vent connection. The 150 nearly doubles input (20–150 vs 8–80 MBH) and capacity while moving to the deeper 20.4-inch cabinet and gaining 32 lb — but its minimum fire rises from 8 to 20 MBH, which matters in low-load homes.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of New Yorker GHE-II GHE2-080 and New Yorker GHE-II GHE2-150
SpecificationNew Yorker GHE-II GHE2-080New Yorker GHE-II GHE2-150
Input, minimum8 MBH20 MBH
Input, maximum80 MBH150 MBH
DOE heating capacity75 MBH141 MBH
Net AHRI water rating65 MBH123 MBH
Efficiency (AFUE)95 %95 %
Vent and air intake2"2"
Boiler weight71 lb103 lb
Boiler depth16.3"20.4"
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater

What actually separates them

Both boilers are direct-vent, sealed-combustion condensing appliances with a 316L stainless-steel heat exchanger, automatic no-touch combustion management, sensor-less rate-based reset and a UL353 boiler flow safety switch. Their rows both print 95.0% AFUE, with the GHE2-080 at 8–80 MBH input and 75 MBH DOE heating capacity against the GHE2-150's 20–150 MBH input and 141 MBH capacity.

The low-fire difference is the practical story: the 080 modulates down to 8 MBH while the 150 stops at 20 MBH. In a home whose design load sits well under 100 MBH, the smaller boiler tracks mild-weather demand more closely and condenses more of the time; the 150 only wins when the calculated load genuinely needs its extra capacity.

Venting is identical — both use the 2-inch direct-vent connection with the same configuration options — but the cabinet depth grows from 16.3 to 20.4 inches and weight from 71 to 103 lb, which matters for wall-mount planning and handling.

CurrentCanadian status unknown
Input
8–80 MBH
Output (max)
—
AFUE
95 %

The New Yorker GHE-II GHE2-080 is the smallest GHE-II heating size and the lowest minimum fire in the line: 8–80 MBH heating input with 75 MBH DOE heating capacity and a 65 MBH net AHRI water rating at 95.0% AFUE on the 316L stainless-steel condensing platform.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
20–150 MBH
Output (max)
—
AFUE
95 %

The New Yorker GHE-II GHE2-150 is the first of the deeper 20.4-inch cabinet sizes: 20–150 MBH heating input with 141 MBH DOE heating capacity and a 123 MBH net AHRI water rating at 95.0% AFUE on the 316L stainless-steel condensing platform.

Natural gasPropaneHeating-only

Frequently asked questions

Do both models use the same vent connection?

Yes — both list a 2-inch vent and air-intake connection with horizontal and vertical two-pipe, concentric, low-profile and hybrid configurations per the GHE-II data sheet.

Which has the lower minimum fire?

The GHE2-080, at 8 MBH input against 20 MBH on the GHE2-150 — a real advantage in low-load homes.

Do both models offer the same warranty?

Yes — the GHE-II data sheet lists a 5-year parts warranty with a 12-year limited heat exchanger warranty across the line.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.