New Yorker GHE-II GHE2-150
The New Yorker GHE-II GHE2-150 is the first of the deeper 20.4-inch cabinet sizes: 20–150 MBH heating input with 141 MBH DOE heating capacity and a 123 MBH net AHRI water rating at 95.0% AFUE on the 316L stainless-steel condensing platform.
Key figures
- Max input
- 150 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 20 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
New Yorker GHE-II GHE2-150 in practice
The GHE-II GHE2-150 is a condensing, direct-vent gas heating boiler rated at 20–150 MBH input. Its row in the GHE-II data sheet prints 141 MBH DOE heating capacity, a 123 MBH net AHRI water rating (1.15 piping and pickup allowance) and 95.0% AFUE, with a 2" vent and air-intake connection, a 20.4"-deep cabinet and a listed weight of 103 lb.
The boiler is wall hung on a pre-installed bracket and wall-mount kit and uses the automatic no-touch combustion management control with built-in self diagnostics, warm-weather shutdown and sensor-less rate-based reset; a UL353 boiler flow safety switch, low gas pressure capability (2.5 in. wc natural gas / 8.0 in. wc LP) and a Grundfos 26-99 circulator are standard on heating-only models. Altitude capability extends to 10,100 feet on SKUs with the 'G00' suffix, and the LP conversion is a two-step field procedure at the gas valve and display with no kit required.
Boilers.ca documents this size at model level from the data sheet and links the published I&O manual. Gas, venting and electrical work belongs with a licensed contractor. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.
Best suited to
- 20-to-150 MBH residential heat-loss loads
- Wall-hung installations with a 2-inch direct-vent route
- Homes pairing the boiler with an indirect water heater
Applicability and support
- Model number
- GHE2-150
- Canadian availability
- unknown
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by New Yorker Boiler. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum | 20 MBH | Minimum heating input per the GHE-II data sheet ratings table. |
| Input, maximum | 150 MBH | Maximum heating input per the GHE-II data sheet ratings table; performance is shown for elevations to 2,000 ft with minimum vent length, and 'G00' SKUs cover altitudes to 10,100 ft. |
| Output | ||
| DOE heating capacity | 141 MBH | DOE heating capacity per the GHE-II data sheet ratings table. |
| Net AHRI water rating | 123 MBH | Net AHRI water rating per the GHE-II data sheet, based on a piping and pickup allowance of 1.15. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95.0% AFUE per the GHE-II data sheet ratings table; the page headline is 95% AFUE. |
| Domestic hot water | ||
| Domestic hot water | Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater | |
| Venting and air | ||
| Vent and air intake | 2" | 2" vent and air-intake connection per the data sheet; horizontal and vertical two-pipe, concentric, low-profile and hybrid configurations are illustrated, plus a polypropylene chimney-chase option. |
| Physical and connections | ||
| Boiler weight | 103 lb | Boiler weight per the GHE-II data sheet ratings table. |
| Boiler depth | 20.4" | Boiler depth per the GHE-II data sheet dimension table; the model is wall hung on the supplied bracket. |
| Water connections | Primary/secondary header with 1-1/4" sweat connections (kit on heating-only models) | The data sheet lists a primary/secondary manifold kit (P/N 111884-01) as an accessory for heating-only models. |
| Gas connection | 1/2" NPT gas connection | Gas connection per the GHE-II data sheet dimension drawing; low gas pressure capability min 2.5 in. wc natural gas / 8.0 in. wc LP. |
| Operating limits and other | ||
| Control | Automatic no-touch combustion management with built-in self diagnostics | Control provides warm-weather shutdown, sensor-less rate-based reset, two inputs (thermostat and DHW) and two-step LP conversion at the gas valve and display; UL353 boiler flow safety switch standard. |
| Fuel | Natural gas or LP gas (two-step conversion, no kit required) | The data sheet describes simple two-step LP conversion with no kit purchase required. |
Manuals
Alerts documented for this model
Frequently asked questions
What are the GHE-II GHE2-150's ratings?
20–150 MBH input, 141 MBH DOE heating capacity, a 123 MBH net AHRI water rating and 95.0% AFUE per the GHE-II data sheet.
How is the GHE-II GHE2-150 vented?
Direct vent, sealed combustion on a 2-inch vent and air-intake connection, with horizontal and vertical two-pipe, concentric, low-profile and hybrid configurations per the data sheet.
Questions about the New Yorker GHE-II GHE2-150?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
Sources and verification
- New Yorker Boiler — GHE-II Heating Boiler product page · accessed September 9, 2026
- GHE-II Data Sheet (PDF) · accessed September 9, 2026
- GHE-II Heating Boiler Installation and Operating Instructions (PDF) · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.