Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

New Yorker GHE-II GHE2-150 vs GHE2-180

Verdict in brief

New Yorker GHE-II GHE2-150 and New Yorker GHE-II GHE2-180 are two condensing boilers from the New Yorker Boiler GHE-II line. The New Yorker GHE-II GHE2-150 is documented at 20–150 MBH input, 141 MBH heating capacity and 95% AFUE, while the New Yorker GHE-II GHE2-180 is documented at 20–180 MBH input, 169 MBH heating capacity and 95% AFUE. New Yorker GHE-II GHE2-180 lists 30 MBH more input than New Yorker GHE-II GHE2-150 (180 MBH against 150 MBH). Both list the same published AFUE of 95%. Both list the same published shipping weight of 103 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of New Yorker GHE-II GHE2-150 and New Yorker GHE-II GHE2-180
SpecificationNew Yorker GHE-II GHE2-150New Yorker GHE-II GHE2-180
Input, minimum20 MBH20 MBH
Input, maximum150 MBH180 MBH
DOE heating capacity141 MBH169 MBH
Net AHRI water rating123 MBH147 MBH
Efficiency (AFUE)95 %95 %
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Boiler weight103 lb103 lb
Boiler depth20.4"20.4"
Water connectionsPrimary/secondary header with 1-1/4" sweat connections (kit on heating-only models)Primary/secondary header with 1-1/4" sweat connections (kit on heating-only models)
Gas connection1/2" NPT gas connection1/2" NPT gas connection
ControlAutomatic no-touch combustion management with built-in self diagnosticsAutomatic no-touch combustion management with built-in self diagnostics
FuelNatural gas or LP gas (two-step conversion, no kit required)Natural gas or LP gas (two-step conversion, no kit required)
Vent and air intake2"2"

What actually separates them

Published ratings: the New Yorker GHE-II GHE2-150 is rated 20–150 MBH input, 141 MBH heating capacity and 95% AFUE; the New Yorker GHE-II GHE2-180 is rated 20–180 MBH input, 169 MBH heating capacity and 95% AFUE. New Yorker GHE-II GHE2-180 lists 30 MBH more input than New Yorker GHE-II GHE2-150 (180 MBH against 150 MBH). Both list the same published AFUE of 95%.

Both records print the same input (20 MBH), AFUE (95%), domestic-hot-water arrangement (Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater) and shipping weight (103 lb), per the cited sources.

CurrentCanadian status unknown
Input
20–150 MBH
Output (max)
—
AFUE
95 %

The New Yorker GHE-II GHE2-150 is the first of the deeper 20.4-inch cabinet sizes: 20–150 MBH heating input with 141 MBH DOE heating capacity and a 123 MBH net AHRI water rating at 95.0% AFUE on the 316L stainless-steel condensing platform.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
20–180 MBH
Output (max)
—
AFUE
95 %

The New Yorker GHE-II GHE2-180 is the largest heating-only GHE-II size: 20–180 MBH heating input with 169 MBH DOE heating capacity and a 147 MBH net AHRI water rating at 95.0% AFUE on the 316L stainless-steel condensing platform.

Natural gasPropaneHeating-only

Frequently asked questions

Which of the two has the higher maximum input?

The New Yorker GHE-II GHE2-180 lists 180 MBH, against 150 MBH on the New Yorker GHE-II GHE2-150, per the cited documentation.

Which model is more efficient?

Both list the same AFUE of 95%.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate