New Yorker PVCG-C PVCG30CN vs PVCG40CN

Verdict in brief

The PVCG30CN and PVCG40CN are the two smallest natural-gas PVCG-C power-vented boilers, both 85.0% AFUE with a 3-inch vent. The 40 raises input from 70.0 to 105.0 MBH and capacity from 60 to 90 MBH while adding 50 lb and one gallon of water content.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of New Yorker PVCG-C PVCG30CN and New Yorker PVCG-C PVCG40CN
SpecificationNew Yorker PVCG-C PVCG30CNNew Yorker PVCG-C PVCG40CN
Input70 MBH105 MBH
Heating capacity60 MBH90 MBH
Net AHRI water rating52 MBH78 MBH
Efficiency (AFUE)85 %85 %
Vent diameter3"3"
Approx. ship weight260 lb310 lb
Dimensions (width × height × depth)12.75" × 37-3/4" × 27-1/4"15.50" × 37-3/4" × 27-1/4"
Water content2 gal3 gal
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater

What actually separates them

Both are power-vented cast-iron water boilers for homes without a chimney, carrying the integrated boiler control with thermal purge, factory-installed LWCO, Taco 007e circulator and a 3-inch vent. Their rows both print 85.0% AFUE: the PVCG30CN at 70.0 MBH input with 60 MBH heating capacity and 52 MBH net AHRI, the PVCG40CN at 105.0/90/78 MBH.

Water content and weight step with the section count — 2 to 3 gallons and 260 to 310 lb — while the cabinet width grows from 12.75 to 15.50 inches. Both use a 1/2-inch gas connection, 1-1/4-inch water connections and the same 50 PSI MAWP with a 30 PSI relief valve shipped standard.

The same capacity steps exist in the LP-gas rows as PVCG30CP and PVCG40CP with lower printed inputs (63.0 and 94.5 MBH); choose the row that matches the fuel supplied to the home.

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The New Yorker PVCG-C PVCG30CN is the smallest PVCG-C size in natural gas: 70 MBH input with 60 MBH heating capacity and a 52 MBH net AHRI water rating at 85% AFUE, power vented in 3".

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The New Yorker PVCG-C PVCG40CN is the second PVCG-C size in natural gas: 105 MBH input with 90 MBH heating capacity and a 78 MBH net AHRI water rating at 85% AFUE, power vented in 3".

Natural gasHeating-only

Frequently asked questions

Do these models need a chimney?

No — the PVCG-C series is power vented for installations without a chimney, and direct-vent conversion kits are listed by model.

What is the LP-gas equivalent of these models?

The PVCG30CP and PVCG40CP rows, printed at 63.0 and 94.5 MBH input respectively at the same 85.0% AFUE.

Are both 3-inch vented?

Yes — the 3-inch vent runs through the PVCG70C size; only the PVCG80C rows step up to a 4-inch vent.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.