Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

New Yorker PVCG-C PVCG30CP vs PVCG30CN

Verdict in brief

Both the New Yorker PVCG-C PVCG30CP and the New Yorker PVCG-C PVCG30CN belong to the New Yorker Boiler PVCG-C line of non-condensing boilers. Published ratings: New Yorker PVCG-C PVCG30CP at 63 MBH input, 54 MBH heating capacity and 85% AFUE; New Yorker PVCG-C PVCG30CN at 70 MBH input, 60 MBH heating capacity and 85% AFUE. New Yorker PVCG-C PVCG30CN lists 7 MBH more input than New Yorker PVCG-C PVCG30CP (70 MBH against 63 MBH). Both list the same published AFUE of 85%. Both list the same published shipping weight of 260 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of New Yorker PVCG-C PVCG30CP and New Yorker PVCG-C PVCG30CN
SpecificationNew Yorker PVCG-C PVCG30CPNew Yorker PVCG-C PVCG30CN
Input63 MBH70 MBH
Heating capacity54 MBH60 MBH
Net AHRI water rating47 MBH52 MBH
Efficiency (AFUE)85 %85 %
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Water content2 gal2 gal
Approx. ship weight260 lb260 lb
Dimensions (width × height × depth)12.75" × 37-3/4" × 27-1/4"12.75" × 37-3/4" × 27-1/4"
VentingPower vented without a chimneyPower vented without a chimney
Supply/return connections1-1/4" supply and 1-1/4" return1-1/4" supply and 1-1/4" return
Gas connection1/2"1/2"
ControlIntegrated boiler control with thermal purge and factory-installed LWCOIntegrated boiler control with thermal purge and factory-installed LWCO
FuelLP gas ('P' SKU)Natural gas ('N' SKU)
Vent diameter3"3"

What actually separates them

Published ratings: the New Yorker PVCG-C PVCG30CP is rated 63 MBH input, 54 MBH heating capacity and 85% AFUE; the New Yorker PVCG-C PVCG30CN is rated 70 MBH input, 60 MBH heating capacity and 85% AFUE. New Yorker PVCG-C PVCG30CN lists 7 MBH more input than New Yorker PVCG-C PVCG30CP (70 MBH against 63 MBH). Both list the same published AFUE of 85%.

The fuel differs: the New Yorker PVCG-C PVCG30CP lists LP gas ('P' SKU), while the New Yorker PVCG-C PVCG30CN lists Natural gas ('N' SKU).

Both records print the same AFUE (85%), domestic-hot-water arrangement (Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater), boiler water content (2 gal) and shipping weight (260 lb), per the cited sources.

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The New Yorker PVCG-C PVCG30CP is the smallest PVCG-C size in LP gas: 63 MBH input with 54 MBH heating capacity and a 47 MBH net AHRI water rating at 85% AFUE, power vented in 3".

PropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The New Yorker PVCG-C PVCG30CN is the smallest PVCG-C size in natural gas: 70 MBH input with 60 MBH heating capacity and a 52 MBH net AHRI water rating at 85% AFUE, power vented in 3".

Natural gasHeating-only

Frequently asked questions

Which of the two has the higher maximum input?

The New Yorker PVCG-C PVCG30CN lists 70 MBH, against 63 MBH on the New Yorker PVCG-C PVCG30CP, per the cited documentation.

Which model is more efficient?

Both list the same AFUE of 85%.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate