NTI Trinity FTG2000 vs FTG2200

Verdict in brief

The FTG2000 and FTG2200 share the same large FTG class — 1,710 lb on the page (2,140 lb with water), a 1 1/2" NPT male gas connection, 3" grooved water connections and the same 235 MBH minimum fire. The 2200 adds 200 MBH of input ceiling and lifts heating capacity from 1,920 to 2,103 MBH and the Net AHRI rating from 1,670 to 1,829 MBH, while thermal efficiency eases from 96% to 95.6%.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of NTI Trinity FTG2000 and NTI Trinity FTG2200
SpecificationNTI Trinity FTG2000NTI Trinity FTG2200
Input, minimum235 MBH235 MBH
Input, maximum2,000 MBH2,200 MBH
Thermal efficiency96 %95.6 %
Heating capacity1,920 MBH2,103 MBH
Net AHRI rating1,670 MBH1,829 MBH
Weight1,710 lb1,710 lb
Weight, with water2,140 lb2,140 lb
Water connections (inlet / outlet)3" grooved joint3" grooved joint
Gas connection1 1/2" NPT male1 1/2" NPT male
Air inlet size8 in8 in
Flue size8 in8 in
Canada altitude derate10% derate at 2,000–4,500 ft10% derate at 2,000–4,500 ft
Domestic hot waterHeating-only; pair with an indirect tank or separate water heaterHeating-only; pair with an indirect tank or separate water heater

What actually separates them

Both boilers fire from the same 235 MBH minimum, so at low fire they behave identically; the FTG2200's 200 MBH of extra ceiling is pure headroom at the top of the range. NTI lists the 2000 at 235 to 2000 MBH input with 96% thermal efficiency, a 1,920 MBH heating capacity and a 1,670 MBH Net AHRI rating.

The 2200 runs 235 to 2200 MBH at 95.6% thermal efficiency with a 2,103 MBH heating capacity and a 1,829 MBH Net AHRI rating. Weight, connections and venting are unchanged: 1,710 lb on the page (2,140 lb with water per the I&O manual), 1 1/2 in NPT male gas, 3 in grooved water connections and 8 in air inlet and flue runs to 150 ft.

Both are heating-only commercial fire-tube boilers under the FTG I&O manual's 10% Canada altitude derate. With the same minimum fire and physical class, the choice is simply whether the plant-demand calculation needs more than 2,000 MBH — if it does not, the 2000 keeps the higher efficiency rating.

CurrentSold in Canada
Input
235–2000 MBH
Output (max)
AFUE

The NTI Trinity FTG2000 is the entry of the 2,000 MBH-class FTG fire-tube boilers: 235 to 2000 MBH input at 96% thermal efficiency, with a 1,920 MBH heating capacity and a 1,670 MBH Net AHRI rating on a 1 1/2" NPT male gas connection.

Natural gasHeating-only
CurrentSold in Canada
Input
235–2200 MBH
Output (max)
AFUE

The NTI Trinity FTG2200 fires 235 to 2200 MBH at 95.6% thermal efficiency with a 2,103 MBH heating capacity and a 1,829 MBH Net AHRI rating — the mid step of NTI's 2,000 MBH-class FTG fire-tube boilers at 1,710 lb.

Natural gasHeating-only

Frequently asked questions

How does the FTG2200 compare with the FTG2000?

Input rises from 235–2000 to 235–2200 MBH, heating capacity from 1,920 to 2,103 MBH and the Net AHRI rating from 1,670 to 1,829 MBH; thermal efficiency eases from 96% to 95.6%. Weight, connections and venting are identical.

Do the two models have the same minimum fire?

Yes — both fire down to 235 MBH per the NTI product page, so the 2200 adds ceiling without raising the low-fire floor.

When is the FTG2200 worth it?

When plant demand exceeds the FTG2000's 2,000 MBH ceiling. With identical low-fire behaviour and physical class, the only reasons to stop at the 2000 are the capacity you would not use and its 0.4-point efficiency edge.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate