Comparison

NTI Trinity FTVN085 vs FTVN110

Verdict in brief

The FTVN085 and FTVN110 are the two smallest heating-only FTVN boilers and share the same 107 lb wall-hung cabinet, connections and venting. The 085 is the only FTVN rated 96% AFUE and fires down to 8.5 MBH; the 110 adds 25 MBH of ceiling at 95% AFUE, so the choice is the calculated heat loss, not floor area.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of NTI Trinity FTVN085 and NTI Trinity FTVN110
SpecificationNTI Trinity FTVN085NTI Trinity FTVN110
Input, minimum8.5 MBH11 MBH
Input, maximum85 MBH110 MBH
Efficiency (AFUE)96 %95 %
Turndown ratioup to 10:1up to 10:1
Weight107 lb107 lb
Max. equivalent vent length, 2"100 ft100 ft
Max. equivalent vent length, 3"150 ft150 ft
CH water connections1 1/4" NPT1 1/4" NPT
Domestic hot waterHeating-only; pair with an indirect tank or separate water heaterHeating-only; pair with an indirect tank or separate water heater

What actually separates them

Both boilers are wall-hung, heating-only condensing units on the same FTVN platform with the same 107 lb weight, the same 1 1/4" NPT CH connections, and the same venting terms — 2" runs to 100 ft or 3" runs to 150 ft per side. NTI rates the FTVN085 at 96% AFUE and the FTVN110 at 95%.

The firing ranges tell the sizing story: the 085 runs 8.5 to 85 MBH and the 110 runs 11 to 110 MBH. In a well-insulated Lower Mainland home the 085's lower minimum fire tracks mild shoulder-season demand more closely; the 110's advantage appears only when the calculated load or indirect-tank recovery needs more than 85 MBH.

Both are heating-only, so domestic hot water comes from an indirect tank or separate water heater on either model, and neither has an installation advantage in weight or venting. The deciding input is the room-by-room heat-loss calculation: under about 85 MBH the 96% AFUE 085 is the better match, and beyond it the 110 earns its place.

CurrentSold in Canada
Input
8.5–85 MBH
Output (max)
AFUE
96 %

The NTI Trinity FTVN085 is the entry point of the FTVN wall-hung condensing family: 8.5 to 85 MBH input at 96% AFUE — the only FTVN rated 96% — in a 107 lb heating-only boiler that also accepts 2" venting to 100 ft for retrofit-friendly runs.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
11–110 MBH
Output (max)
AFUE
95 %

The NTI Trinity FTVN110 is the 95% AFUE mid-size heating-only member of the FTVN wall-hung family, firing 11 to 110 MBH in the same 107 lb cabinet as the FTVN085, with 2" venting to 100 ft or 3" to 150 ft per side.

Natural gasPropaneHeating-only

Frequently asked questions

Which FTVN is more efficient?

The FTVN085 is rated 96% AFUE and the FTVN110 95%, per NTI's product table — the 085 is the only 96% model in the FTVN line.

Are the two models the same size?

Yes. Both weigh 107 lb with the same cabinet, connections and venting; only the firing range (85 vs 110 MBH) and the AFUE rating differ.

When should I choose the FTVN110?

When the heat-loss calculation plus hot-water recovery demand more than 85 MBH on a design day. Extra input without a matching load just raises the minimum fire the boiler idles at.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.