Comparison

NTI Trinity Lx200 vs Lx300

Verdict in brief

The Lx200 and Lx300 are the bridge between the light Lx sizes and the commercial class: the Lx300 fires 55 to 275 MBH instead of 25 to 199 MBH, steps its efficiency to 93.7% AFUE, and moves to 4" venting with 1 1/4" water connections at 180 lb against the Lx200's 125 lb and 3" venting.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of NTI Trinity Lx200 and NTI Trinity Lx300
SpecificationNTI Trinity Lx200NTI Trinity Lx300
Input, minimum25 MBH55 MBH
Input, maximum199 MBH275 MBH
Efficiency (AFUE)93.5 %93.7 %
Weight125 lb180 lb
Max. equivalent vent length105 ft100 ft
Water connections1" NPT female1 1/4" NPT female
Gas connection1/2" NPT female1/2" NPT female
Domestic hot waterHeating-only; pair with an indirect tank or separate water heaterHeating-only; pair with an indirect tank or separate water heater

What actually separates them

NTI publishes the Lx200 at 25 to 199 MBH at 93.5% AFUE, and the Lx300 at 55 to 275 MBH at 93.7% AFUE. The 300 also changes the installation class: its venting moves from 3" (105 ft) to 4" (100 ft per side), and its water connections from 1" to 1 1/4" NPT female.

Weight rises from 125 lb on the Lx200 to 180 lb on the Lx300, and the minimum fire jumps from 25 to 55 MBH — the clearest sign that the 300 expects a sustained plant load rather than a house-scale modulating range.

Both are heating-only fire-tube boilers; domestic hot water is produced separately. The 300 is the right step when the heat-loss or plant-demand calculation exceeds 199 MBH and the mechanical room can take 4" venting; loads inside the 200's range keep the lighter unit, 3" venting and the low 25 MBH minimum fire.

CurrentSold in Canada
Input
25–199 MBH
Output (max)
—
AFUE
93.5 %

The NTI Trinity Lx200 stretches the Lx entry class to 199 MBH: 25 to 199 MBH input at 93.5% AFUE in a 125 lb floor-standing boiler with a wall-hung kit included, on 3" venting to 105 ft.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
55–275 MBH
Output (max)
—
AFUE
93.7 %

The NTI Trinity Lx300 is the 93.7% AFUE step of the Lx line: 55 to 275 MBH input in a 180 lb floor-standing boiler, stepping up to 4" venting at 100 ft with 1 1/4" NPT water connections.

Natural gasPropaneHeating-only

Frequently asked questions

What changes between the Lx200 and the Lx300?

Input rises to 275 MBH (minimum 55 MBH), AFUE to 93.7%, weight to 180 lb, and venting steps from 3" to 4" pipe; water connections move up to 1 1/4" NPT female.

Does the Lx300 still allow 3" venting?

No. NTI lists 4" pipe for the Lx300, with a 100 ft maximum equivalent run per side.

Is the Lx300 suitable for a house?

Only a large one: its 55 MBH minimum fire assumes a substantial load, so a house-scale calculation should justify it rather than defaulting to a bigger boiler.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate