NTI Trinity Lx300

The NTI Trinity Lx300 is the 93.7% AFUE step of the Lx line: 55 to 275 MBH input in a 180 lb floor-standing boiler, stepping up to 4" venting at 100 ft with 1 1/4" NPT water connections.

CurrentSold in Canada

Key figures

Max input
275 MBH
Max CSA output
—
AFUE
93.7 %
Min input
55 MBH
Natural gasPropaneHeating-onlyresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

NTI Trinity Lx300 in practice

The Lx300 lifts the Lx range to a 275 MBH ceiling at 93.7% AFUE — the only AFUE figure NTI prints between the 93.5% smaller models and the 94% larger ones. It weighs 180 lb, moves water connections up to 1 1/4" NPT female while keeping a 1/2" NPT gas connection, and its venting steps to 4" pipe with a 100 ft maximum run per side.

With a 55 MBH minimum fire, the 300 assumes a sustained load rather than small-house operation: the audience is large residences, multi-suite buildings and light-commercial plants whose heat-loss calculation lands between the 200 and the 400. The 4" vent requirement is worth checking early, since it changes the pipe plan compared with the 3" smaller models.

Best suited to

  • Light-commercial plants and large residences with loads around 275 MBH
  • Projects whose loads outgrow the Lx200's 199 MBH ceiling
  • Mechanical rooms that can run 4" venting within 100 ft per side

Applicability and support

Model number
Lx300
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.

NTI Trinity Lx300 specifications
SpecificationValueNote
Input
Input, minimum55 MBHPer the NTI product page.
Input, maximum275 MBHPer the NTI product page.
Efficiency
Efficiency (AFUE)93.7 %Per the NTI product page.
Domestic hot water
Domestic hot waterHeating-only; pair with an indirect tank or separate water heater
Venting and air
Max. equivalent vent length100 ft4" pipe per side; maximum equivalent run per the NTI product page.
Physical and connections
Weight180 lbPer the NTI product page.
Water connections1 1/4" NPT femalePer the NTI product page.
Gas connection1/2" NPT femalePer the NTI product page.
Operating limits and other
FuelNatural gas or propaneNTI publishes LP conversion instructions for this series.

Manuals

Alerts documented for this model

Services

Frequently asked questions

What venting does the Lx300 need?

4" pipe with a 100 ft maximum equivalent run per side, per the NTI product page — a step up from the 3" pipe used on the Lx150 and Lx200.

What is the Lx300's efficiency?

93.7% AFUE per the NTI product page, between the 93.5% of the Lx150/200 and the 94% of the Lx400 and larger models.

Is the Lx300 wall-hung?

It can be — NTI's features list includes the wall-hung kit for the Lx200–400 sizes — though at 180 lb the mounting plan needs a contractor's assessment.

Questions about the NTI Trinity Lx300?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate