Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

NTI Compass NC085 vs NC110

Verdict in brief

The Compass NC085 and NC110 are the two smallest heating-only Compass floor boilers and share the same 193 lb floor cabinet, connections and venting. The NC085 is the only Compass rated 96% AFUE and fires down to 8.5 MBH; the NC110 adds 25 MBH of ceiling at 95%, so the heat-loss calculation decides which footprint replacement fits.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of NTI Compass NC085 and NTI Compass NC110
SpecificationNTI Compass NC085NTI Compass NC110
Input, minimum8.5 MBH11 MBH
Input, maximum85 MBH110 MBH
Efficiency (AFUE)96 %95 %
Turndown ratioup to 10:1up to 10:1
Weight193 lb193 lb
Max. equivalent vent length, 2"100 ft100 ft
Max. equivalent vent length, 3"150 ft150 ft
CH water connections1 1/4" NPT1 1/4" NPT
Domestic hot waterHeating-only; pair with an indirect tank or separate water heaterHeating-only; pair with an indirect tank or separate water heater

What actually separates them

Both floor-standing Compass models share the platform's stainless fire-tube heat exchanger, integrated ECM pump with primary/secondary piping and reversible connections, in the same 193 lb floor cabinet with the same 1 1/4" NPT CH connections and 2" (100 ft) / 3" (150 ft) venting.

The published differences are efficiency and range: NTI rates the NC085 at 96% AFUE firing 8.5 to 85 MBH, and the NC110 at 95% firing 11 to 110 MBH. In a low-load home the 085's lower minimum fire tracks BC's mild weather more steadily; the 110 answers to loads above 85 MBH.

Neither model heats domestic hot water, so an indirect tank or separate water heater serves DHW on both. With the cabinet, footprint logic and connections identical, the deciding input is the room-by-room heat-loss calculation — under 85 MBH the 96% NC085, and beyond it the NC110.

CurrentSold in Canada
Input
8.5–85 MBH
Output (max)
—
AFUE
96 %

The NTI Compass NC085 is the smallest floor-standing Compass: 8.5 to 85 MBH input, the only Compass rated 96% AFUE, in a 193 lb floor cabinet designed to drop into an existing boiler footprint.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
11–110 MBH
Output (max)
—
AFUE
95 %

The NTI Compass NC110 is the 95% AFUE floor-standing Compass at 11 to 110 MBH input — the same 193 lb cabinet as the NC085 with 25 MBH more ceiling for detached homes with an indirect tank.

Natural gasPropaneHeating-only

Frequently asked questions

Which Compass model is more efficient?

The NC085 at 96% AFUE; the NC110 is rated 95% per NTI's Compass table — the NC085 is the only 96% model in the line.

Do the two models share a cabinet?

Yes. Both are floor-standing at 193 lb with the same reversible connections and 2"/3" venting terms; only the firing range differs.

When should I choose the NC110?

When the heat-loss calculation plus hot-water recovery demand more than the NC085's 85 MBH ceiling. Extra input without a matching load raises the minimum fire in mild weather.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate