Key figures

Max input
110 MBH
Max CSA output
AFUE
95 %
Min input
11 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

NTI Compass NC110 in practice

The NC110 lifts the Compass line to an 110 MBH ceiling at 95% AFUE while keeping the 193 lb floor cabinet shared with the NC085. It is heating-only on 1 1/4" NPT CH connections, with domestic hot water from an indirect tank or separate water heater, and carries the same integrated ECM pump and primary/secondary piping as the rest of the platform.

For homes whose heat-loss calculation exceeds the NC085's 85 MBH — or that add recovery demand through an indirect tank — the NC110 adds ceiling with no footprint change, since the Compass cabinet is common across the heating models up to the NC199. Its 11 MBH minimum fire keeps low-load modulation practical in BC's mild climate.

Best suited to

  • Detached homes whose load calculation lands between 85 and 110 MBH
  • Houses pairing the floor-standing Compass with an indirect tank
  • Retrofits wanting a floor-footprint replacement with more headroom than the NC085

Applicability and support

Model number
NC110
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.

NTI Compass NC110 specifications
SpecificationValueNote
Input
Input, minimum11 MBHPer the NTI product page.
Input, maximum110 MBHPer the NTI product page.
Efficiency
Efficiency (AFUE)95 %DOE AFUE per the NTI product page.
Domestic hot water
Domestic hot waterHeating-only; pair with an indirect tank or separate water heater
Venting and air
Max. equivalent vent length, 2"100 ftEach side per the I&O manual.
Max. equivalent vent length, 3"150 ftEach side per the I&O manual.
Physical and connections
Weight193 lbPer the NTI product page.
CH water connections1 1/4" NPTMale NPT per the NTI product page.
Gas connection3/4" NPTMale NPT per the NTI product page.
Operating limits and other
FuelNatural gas or propaneNTI publishes LP conversion instructions for this series.
Turndown ratioup to 10:1Manufacturer marketing figure on the NTI product page.

Frequently asked questions

How does the NC110 compare with the NC085?

Both are heating-only Compass models in the same 193 lb floor cabinet. The NC110 fires 11 to 110 MBH at 95% AFUE; the NC085 fires 8.5 to 85 MBH at 96%.

Does the NC110 need a wall?

No — the Compass is floor-standing. NTI markets it as dropping into an existing floor-mounted footprint without wall construction or stands.

What are the NC110's venting limits?

2" runs to 100 ft or 3" runs to 150 ft per side, per the NTI Compass product page.

Questions about the NTI Compass NC110?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate