Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

NTI Trinity TFTN110 vs TFTN150

Verdict in brief

The TFTN110 and TFTN150 are both 95% AFUE heating-only TFTN wall models, and the 150 adds 40 MBH of ceiling (150 vs 110 MBH) for 15 lb more weight and a cabinet that deepens from 17 1/4 to 18 3/4 inches. Minimum fire rises from 11 to 15 MBH; connections and venting are unchanged.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of NTI Trinity TFTN110 and NTI Trinity TFTN150
SpecificationNTI Trinity TFTN110NTI Trinity TFTN150
Input, minimum11 MBH15 MBH
Input, maximum110 MBH150 MBH
Efficiency (AFUE)95 %95 %
Weight107 lb122 lb
Width19.875 in19.875 in
Height34.125 in34.125 in
Depth17.25 in18.75 in
Max. equivalent vent length, 2"100 ft100 ft
Max. equivalent vent length150 ft150 ft
CH water connections1 1/4" NPT1 1/4" NPT
Domestic hot waterHeating-only; pair with an indirect tank or separate water heaterHeating-only; pair with an indirect tank or separate water heater

What actually separates them

Both models share the TFTN wall platform at 95% AFUE with the same 19 7/8 inch width and 34 1/8 inch height, the same 1 1/4" NPT CH connections and the same 2" (100 ft) and 3" (150 ft) venting terms. The 150 differs in depth (18 3/4 inches against 17 1/4), weight (122 lb against 107 lb with water) and range (15 to 150 MBH against 11 to 110 MBH).

The minimum fire steps up from 11 to 15 MBH between them — a modest change that keeps the 150 practical in mild BC weather — while the 150's ceiling covers homes whose heat-loss plus indirect-tank recovery demand more than the 110 can deliver.

Neither model produces domestic hot water, so the indirect tank or separate water heater is common to both. The deciding input remains the room-by-room heat-loss calculation: loads beyond 110 MBH justify the deeper, heavier 150; smaller loads keep the lighter cabinet and lower minimum fire of the 110.

CurrentSold in Canada
Input
11–110 MBH
Output (max)
—
AFUE
95 %

The NTI Trinity TFTN110 is the 95% AFUE wall-hung TFTN between the 085 and the 150: 11 to 110 MBH input in the same 107 lb cabinet as the TFTN085, with 2" venting to 100 ft or 3" to 150 ft.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
15–150 MBH
Output (max)
—
AFUE
95 %

The NTI Trinity TFTN150 is the 95% AFUE wall-hung TFTN for mid-to-larger homes: 15 to 150 MBH input, 122 lb with water, on 1 1/4" NPT CH connections with 2" venting to 100 ft or 3" to 150 ft.

Natural gasPropaneHeating-only

Frequently asked questions

What does the TFTN150 change over the TFTN110?

Input rises from 110 to 150 MBH, weight from 107 to 122 lb with water, and cabinet depth from 17 1/4 to 18 3/4 inches. Width, height, AFUE and connections are unchanged.

Does the TFTN150 still allow 2" venting?

Yes — 2" to 100 ft and 3" to 150 ft per side, with no bulletin restriction on the TFTN wall models.

When is the TFTN110 enough?

When the heat-loss calculation plus recovery demand fits within 110 MBH. The 110 keeps the lighter cabinet and the 11 MBH minimum fire, which tracks mild weather more closely.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate