NTI Trinity TFTN150

The NTI Trinity TFTN150 is the 95% AFUE wall-hung TFTN for mid-to-larger homes: 15 to 150 MBH input, 122 lb with water, on 1 1/4" NPT CH connections with 2" venting to 100 ft or 3" to 150 ft.

CurrentSold in Canada

Key figures

Max input
150 MBH
Max CSA output
AFUE
95 %
Min input
15 MBH
Natural gasPropaneHeating-onlyresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

NTI Trinity TFTN150 in practice

The TFTN150 steps the wall family up to a 150 MBH ceiling with a slightly deeper cabinet (18 3/4 inches against 17 1/4 on the 085 and 110) and 122 lb with water. It keeps the 1 1/4" NPT CH connections of the smaller sizes and the same touchscreen control, and it is heating-only, pairing with an indirect tank for domestic hot water.

Between the 110 and the 199, the 150 is the size most often selected when a heat-loss calculation plus hot-water recovery outgrows 110 MBH but stops short of the 199's territory. Its 15 MBH minimum fire still tracks mild Lower Mainland weather reasonably well, and the 2" vent option remains open to 100 ft per side.

Best suited to

  • Mid-to-larger detached homes needing more than the TFTN110's ceiling
  • Houses with radiators or in-floor loops plus an indirect tank
  • Retrofits that keep the wall-hung family's 2" venting option

Applicability and support

Model number
TFTN150
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.

NTI Trinity TFTN150 specifications
SpecificationValueNote
Input
Input, minimum15 MBHPer the NTI product page.
Input, maximum150 MBHPer the NTI product page.
Efficiency
Efficiency (AFUE)95 %Per the NTI product page.
Domestic hot water
Domestic hot waterHeating-only; pair with an indirect tank or separate water heater
Venting and air
Max. equivalent vent length, 2"100 ft2" pipe; up to 100 ft each per the NTI product page.
Max. equivalent vent length150 ft3" pipe; up to 150 ft each per the NTI product page.
Physical and connections
Weight122 lbWith water, per the NTI product page.
CH water connections1 1/4" NPTMale NPT per the NTI product page.
Gas connection3/4" NPTMale NPT per the NTI product page.
Width19.875 inPer the TFTN I&O manual, Table 2-1.
Height34.125 inPer the TFTN I&O manual, Table 2-1.
Depth18.75 inPer the TFTN I&O manual, Table 2-1.
Operating limits and other
FuelNatural gas or propaneNTI publishes LP conversion instructions for this series.

Frequently asked questions

What are the TFTN150's physical dimensions?

19 7/8 by 34 1/8 by 18 3/4 inches (width, height, depth) at 122 lb with water, per the I&O manual's Table 2-1.

Is the TFTN150 efficient?

NTI rates it 95% AFUE, the same as the 110, 199 and 285 wall models; the TFTN085 is the only 96% AFUE wall model.

Does the TFTN150 need 3" venting?

No — NTI lists 2" to 100 ft and 3" to 150 ft per side for this model, so both routes are available.

Questions about the NTI Trinity TFTN150?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate