NTI Trinity TRX150C vs TRX199C

Verdict in brief

The TRX150C and TRX199C are the two largest TRX combis, both rated 95% AFUE. The 199C jumps to the heavy class: 135 lb with 1 1/4" NPT CH connections, heating input to 197 MBH (LP 192) and 4.8 GPM continuous DHW, against the 150C's 92.8 lb, 120 MBH and 3.5 GPM — with bulletin-restricted 2" venting terms.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of NTI Trinity TRX150C and NTI Trinity TRX199C
SpecificationNTI Trinity TRX150CNTI Trinity TRX199C
Space-heating input, minimum13.2 MBH19.7 MBH
Space-heating input, maximum120 MBH197 MBH
Efficiency (AFUE)95 %95 %
Turndown ratioup to 11:1up to 11:1
Weight92.8 lb135 lb
Max. equivalent vent length, 2"100 ft100 ft
Max. equivalent vent length, 3"150 ft150 ft
CH water connections1" male sweat with adapter1 1/4" NPT
DHW connections3/4" male sweat with adapter3/4" NPT
DHW capacity at 77°F rise3.5 GPM4.8 GPM
Domestic hot waterIntegrated combi (DHW plate) in the applianceIntegrated combi (DHW plate) in the appliance

What actually separates them

The 150C sits on the TRX light chassis (92.8 lb, 1" male sweat CH connections, 3/4" sweat DHW connections), while the 199C moves to the heavy class: 135 lb, 1 1/4" NPT CH connections and a 3/4" NPT DHW connection. Both are rated 95% AFUE.

Heating input climbs from 13.2 to 120 MBH on the 150C to 19.7 to 197 MBH on the 199C (LP: 19.2 to 192 MBH), and NTI rates continuous DHW at 3.5 GPM for the 150C and 4.8 GPM for the 199C at a 77°F rise. The 199C's DHW rating is the strongest in the TRX combi line.

The 199C costs more than weight and piping class: its 19.7 MBH minimum fire is the highest in the TRX series, and its 2" venting terms follow NTI technical bulletin 2022-10-26, so 3" pipe to 150 ft per side is the planning figure. It belongs in larger homes and small multi-suite plants whose heat and hot-water calculations both approach its ratings.

CurrentSold in Canada
Input
13.2–120 MBH
Output (max)
AFUE
95 %

The NTI Trinity TRX150C is the mid-size TRX combi: space heating at 13.2 to 120 MBH input and 3.5 GPM continuous DHW at a 77°F rise, rated 95% AFUE in a 92.8 lb wall-hung boiler.

Natural gasPropaneCombi
CurrentSold in Canada
Input
19.7–197 MBH
Output (max)
AFUE
95 %

The NTI Trinity TRX199C is the flagship TRX combi: space heating at 19.7 to 197 MBH (LP 19.2 to 192 MBH) with 4.8 GPM continuous DHW at a 77°F rise, rated 95% AFUE at 135 lb with 1 1/4" NPT CH connections.

Natural gasPropaneCombi

Frequently asked questions

How much hot water does the TRX199C deliver?

4.8 GPM continuous at a 77°F rise, against 3.5 GPM on the TRX150C — the highest DHW rating in the TRX line.

Why does the 199C need different piping?

It moves from the light chassis' 1" sweat CH connections to 1 1/4" NPT, and its 3/4" DHW connection is NPT rather than sweat, matching the larger near-boiler flow rates.

When is the 199C overkill?

When the heat-loss calculation is well below 150 MBH. Its 19.7 MBH minimum fire and heavier 135 lb chassis are only justified when heating and DHW demand genuinely approach its range.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate