The NTI Trinity TRX199C is the flagship TRX combi: space heating at 19.7 to 197 MBH (LP 19.2 to 192 MBH) with 4.8 GPM continuous DHW at a 77°F rise, rated 95% AFUE at 135 lb with 1 1/4" NPT CH connections.

CurrentSold in Canada

Key figures

Max input
197 MBH
Max CSA output
—
AFUE
95 %
Min input
19.7 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

NTI Trinity TRX199C in practice

The TRX199C is the largest TRX and the strongest combi in the line: heating up to 197 MBH on natural gas (192 MBH on LP) plus a domestic hot water plate rated for 4.8 GPM continuous at a 77°F rise. It steps to 1 1/4" NPT CH connections and 3/4" NPT DHW connections and weighs 135 lb.

The DHW figure is the reason this model exists — 4.8 GPM continuous covers most two-bathroom households without a tank — but the boiler must also be right for the heating side. Its 19.7 MBH minimum fire is the highest in the TRX line, and its 2" venting terms follow NTI technical bulletin 2022-10-26, so installations plan on 3" pipe to 150 ft per side. In BC, that combination points to large homes and small multi-suite buildings rather than average detached houses.

Best suited to

  • Large homes wanting one appliance for heat and high-volume hot water
  • Small multi-suite or strata hydronic plants within the TRX's 197 MBH input
  • Households whose simultaneous DHW draws exceed the 150C's 3.5 GPM

Applicability and support

Model number
TRX199C
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.

NTI Trinity TRX199C specifications
SpecificationValueNote
Input
Space-heating input, minimum19.7 MBHNatural gas. LP minimum is 19.2 MBH per the NTI product page.
Space-heating input, maximum197 MBHNatural gas. LP maximum is 192 MBH per the NTI product page.
Efficiency
Efficiency (AFUE)95 %DOE AFUE per the NTI product page.
Domestic hot water
DHW capacity at 77°F rise4.8 GPMContinuous delivery per the NTI product page.
Domestic hot waterIntegrated combi (DHW plate) in the appliance
Venting and air
Max. equivalent vent length, 2"100 ftEach side per the I&O manual; the 2" terms on this model follow NTI technical bulletin 2022-10-26.
Max. equivalent vent length, 3"150 ftEach side per the I&O manual.
Physical and connections
Weight135 lbPer the NTI product page.
CH water connections1 1/4" NPTPer the NTI product page.
DHW connections3/4" NPTPer the NTI product page.
Gas connection3/4" NPTMale NPT per the NTI product page.
Operating limits and other
FuelNatural gas or propaneNTI publishes LP conversion instructions for this series.
Turndown ratioup to 11:1Manufacturer marketing figure on the NTI product page.

Frequently asked questions

How much hot water can the TRX199C deliver?

4.8 GPM continuous at a 77°F rise per the NTI product page — the highest DHW rating in the TRX combi line, against 3.5 GPM on the TRX150C.

Does the TRX199C have LP-specific ratings?

Yes. NTI lists 19.7 to 197 MBH on natural gas and 19.2 to 192 MBH on propane for the TRX199C's input range.

Can the TRX199C vent in 2" pipe?

NTI's page lists 2" runs to 100 ft but marks the 2" terms per technical bulletin 2022-10-26, so 3" piping to 150 ft per side is the planning figure.

Questions about the NTI Trinity TRX199C?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.