NTI Trinity TRX199C
The NTI Trinity TRX199C is the flagship TRX combi: space heating at 19.7 to 197 MBH (LP 19.2 to 192 MBH) with 4.8 GPM continuous DHW at a 77°F rise, rated 95% AFUE at 135 lb with 1 1/4" NPT CH connections.
Key figures
- Max input
- 197 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 19.7 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
NTI Trinity TRX199C in practice
The TRX199C is the largest TRX and the strongest combi in the line: heating up to 197 MBH on natural gas (192 MBH on LP) plus a domestic hot water plate rated for 4.8 GPM continuous at a 77°F rise. It steps to 1 1/4" NPT CH connections and 3/4" NPT DHW connections and weighs 135 lb.
The DHW figure is the reason this model exists — 4.8 GPM continuous covers most two-bathroom households without a tank — but the boiler must also be right for the heating side. Its 19.7 MBH minimum fire is the highest in the TRX line, and its 2" venting terms follow NTI technical bulletin 2022-10-26, so installations plan on 3" pipe to 150 ft per side. In BC, that combination points to large homes and small multi-suite buildings rather than average detached houses.
Best suited to
- Large homes wanting one appliance for heat and high-volume hot water
- Small multi-suite or strata hydronic plants within the TRX's 197 MBH input
- Households whose simultaneous DHW draws exceed the 150C's 3.5 GPM
Applicability and support
- Model number
- TRX199C
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Space-heating input, minimum | 19.7 MBH | Natural gas. LP minimum is 19.2 MBH per the NTI product page. |
| Space-heating input, maximum | 197 MBH | Natural gas. LP maximum is 192 MBH per the NTI product page. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | DOE AFUE per the NTI product page. |
| Domestic hot water | ||
| DHW capacity at 77°F rise | 4.8 GPM | Continuous delivery per the NTI product page. |
| Domestic hot water | Integrated combi (DHW plate) in the appliance | |
| Venting and air | ||
| Max. equivalent vent length, 2" | 100 ft | Each side per the I&O manual; the 2" terms on this model follow NTI technical bulletin 2022-10-26. |
| Max. equivalent vent length, 3" | 150 ft | Each side per the I&O manual. |
| Physical and connections | ||
| Weight | 135 lb | Per the NTI product page. |
| CH water connections | 1 1/4" NPT | Per the NTI product page. |
| DHW connections | 3/4" NPT | Per the NTI product page. |
| Gas connection | 3/4" NPT | Male NPT per the NTI product page. |
| Operating limits and other | ||
| Fuel | Natural gas or propane | NTI publishes LP conversion instructions for this series. |
| Turndown ratio | up to 11:1 | Manufacturer marketing figure on the NTI product page. |
Manuals
- TRX 085–150C I&O Manual, 86341 / 420010970805 Rev 01.24.23420010970805 Rev 01 · 2023-01-24
- TRX 150–199C I&O Manual, 420011303700 (Rev 2024.02.16)420011303700 · 2024-02-16
- TRX Series II 085–150C I&O Manual, 420012001500 Rev 04 (03182024)420012001500 Rev 04 · 2024-03-18
- TRX Series II 150–199C I&O Manual, 420012001300 Rev 05 (061824)420012001300 Rev 05 · 2024-06-18
Alerts documented for this model
- 1 01
- 1 03
- 1 04
- 1 05
- 1 06
- 1 07
- 1 08
- 1 10
- 1 12
- 1 14
- 115
- 1 16
- 150
- 1 P1
- 1 P2
- 1 P3
- 201
- 2 03
- 2 05
- 2 09
- 2 P2
- 3 01
- 3 02
- 3 03
- 3 04
- 3 05
- 3 06
- 3 07
- 3 09
- 3 P9
- 4 11
- 4 12
- 4 13
- 4 30
- 4 31
- 440
- 4 41
- 5 01
- 5 02
- 5 04
- 5 P1
- 5 P2
- 5 P6
- 5 P3
- 6 02
- 6 03
- 6 05
- 6 12
- 6 19
- NOAVL
- EMERG
- CONFL
- 1 01
- 1 03
- 1 04
- 1 05
- 1 06
- 1 07
- 1 08
- 1 10
- 1 12
- 1 14
- 115
- 1 16
- 150
- 1 P1
- 1 P2
- 1 P3
- 201
- 2 03
- 2 05
- 2 09
- 2 P2
- 3 01
- 3 02
- 3 03
- 3 04
- 3 05
- 3 06
- 3 07
- 3 09
- 3 P9
- 4 11
- 4 12
- 4 13
- 4 30
- 4 31
- 440
- 4 41
- 5 01
- 5 02
- 5 04
- 5 P1
- 5 P2
- 5 P6
- 5 P3
- 6 02
- 6 03
- 6 05
- 6 12
- 6 19
- NOAVL
- EMERG
- CONFL
- 1 01
- 1 03
- 1 04
- 1 05
- 1 06
- 1 07
- 1 08
- 1 10
- 1 12
- 1 14
- 115
- 1 16
- 150
- 1 P1
- 1 P2
- 1 P3
- 201
- 2 03
- 2 05
- 2 09
- 2 P2
- 3 01
- 3 02
- 3 03
- 3 04
- 3 05
- 3 06
- 3 07
- 3 09
- 3 11
- 3 P9
- 4 11
- 4 12
- 4 13
- 4 30
- 4 31
- 440
- 4 41
- 5 01
- 5 02
- 5 04
- 5 P1
- 5 P2
- 5 P6
- 5 P3
- 6 02
- 6 03
- 6 05
- 6 12
- 6 19
- NOAVL
- EMERG
- CONFL
- 1 01
- 1 02
- 1 03
- 1 04
- 1 05
- 1 06
- 1 07
- 1 08
- 1 10
- 1 12
- 1 14
- 115
- 1 16
- 150
- 1 P1
- 1 P2
- 1 P3
- 201
- 2 03
- 2 05
- 2 09
- 2 P2
- 3 01
- 3 02
- 3 03
- 3 04
- 3 05
- 3 06
- 3 07
- 3 09
- 3 11
- 3 P9
- 4 11
- 4 12
- 4 13
- 4 30
- 4 31
- 440
- 4 41
- 5 01
- 5 02
- 5 04
- 5 P1
- 5 P2
- 5 P6
- 5 P3
- 6 02
- 6 03
- 6 05
- 6 12
- 6 19
- NOAVL
- EMERG
- CONFL
Frequently asked questions
How much hot water can the TRX199C deliver?
4.8 GPM continuous at a 77°F rise per the NTI product page — the highest DHW rating in the TRX combi line, against 3.5 GPM on the TRX150C.
Does the TRX199C have LP-specific ratings?
Yes. NTI lists 19.7 to 197 MBH on natural gas and 19.2 to 192 MBH on propane for the TRX199C's input range.
Can the TRX199C vent in 2" pipe?
NTI's page lists 2" runs to 100 ft but marks the 2" terms per technical bulletin 2022-10-26, so 3" piping to 150 ft per side is the planning figure.
Questions about the NTI Trinity TRX199C?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- NTI Trinity TRX150C vs TRX199CComparison
- IBC SFC 199-1 Superflow vs NTI Trinity TRX199CComparison
- NTI Trinity TRX085Same series
- NTI Trinity TRX120Same series
- NTI Trinity TRX150Same series
- NTI Trinity TRX199Same series
- NTI Trinity TRX110CSame series
- NTI Trinity TRX150CSame series
- Trinity TRX series hub
- Buying guide
Sources and verification
- NTI — TRX Series product page · accessed September 7, 2026
- NTI — TRX Series II product page · accessed September 7, 2026
- TRX 085–150C I&O Manual, 86341 / 420010970805 Rev 01.24.23 · 420010970805 Rev 01 · accessed September 7, 2026
- TRX 150–199C I&O Manual, 420011303700 (Rev 2024.02.16) · 420011303700 · accessed September 7, 2026
- TRX Series II 085–150C I&O Manual, 420012001500 Rev 04 (03182024) · 420012001500 Rev 04 · accessed September 7, 2026
- TRX Series II 150–199C I&O Manual, 420012001300 Rev 05 (061824) · 420012001300 Rev 05 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.