P-K MODU-FIRE FD N1500 vs N2000

Verdict in brief

The MODU-FIRE FD N1500 and N2000 share the same 54" × 32" × 68" shipping box, 985 lb operating weight, 7.3-gallon water content, 206 sq. ft. heated surface and 2-1/2" water connections; the N2000 adds 500 MBH of input and 425 MBH of output, steps gas up from 1-1/4" to 1-1/2", ships 30 lb heavier and moves 170 GPM at 20°F ΔT versus 127.5 GPM.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of P-K MODU-FIRE FD N1500 and P-K MODU-FIRE FD N2000
SpecificationP-K MODU-FIRE FD N1500P-K MODU-FIRE FD N2000
Input1,500 MBH2,000 MBH
Output1,275 MBH1,700 MBH
Efficiency (page)88 %88 %
Turndown ratio5:15:1
Main gas connection1 1/4" NPT-F1 1/2" NPT-F
Boiler supply / return2 1/2" NPT (supply F / return M)2 1/2" NPT (supply F / return M)
Operating weight985 lb985 lb
Shipping weight960 lb990 lb
Boiler water content7.3 gal7.3 gal
Boiler HP3850.8
Heated wet surface area206 sq. ft.206 sq. ft.
Flow rate @ 20°F ΔT127.5 GPM170 GPM
Combustion air inlet8" dia. stub8" dia. stub
Exhaust vent8" (6" with adapter)8" (6" with adapter)
Shipping width32 in32 in
Shipping length54 in54 in
Shipping height68 in68 in

What actually separates them

P-K's submittal prints the N1500MFD at 1,500,000 BTU/hr input / 1,275,000 BTU/hr output and the N2000MFD at 2,000,000 / 1,700,000, both at 38.0 and 50.8 boiler HP respectively. The submittal does not print a minimum-input or turndown row for these two sizes; the 5:1 turndown is the series figure on the product page.

The package is shared: 54" × 32" × 68" shipping dimensions, 985 lb operating weight, 7.3 gallons of water, 206 sq. ft. heated surface, 2-1/2" NPT supply/return, an 8" combustion-air stub and an 8" exhaust (6" with adapter).

Two things change: the main gas connection steps from 1-1/4" to 1-1/2" NPT, and the flow rate at a 20°F ΔT rises from 127.5 to 170 GPM. Shipping weight goes from 960 lb to 990 lb. Both require Category II or IV venting.

Patterson-Kelley

P-K MODU-FIRE FD N1500

CurrentCanadian status unknown
Input
Output (max)
1,275 MBH
AFUE

The P-K MODU-FIRE FD N1500 is a forced-draft non-condensing commercial boiler rated 1500 MBH input and 1275 MBH output in Patterson-Kelley's published submittal, with 5:1 turndown and a 985 lb operating weight.

Natural gasHeating-only

Patterson-Kelley

P-K MODU-FIRE FD N2000

CurrentCanadian status unknown
Input
Output (max)
1,700 MBH
AFUE

The P-K MODU-FIRE FD N2000 is a forced-draft non-condensing commercial boiler rated 2000 MBH input and 1700 MBH output in Patterson-Kelley's published submittal, with 5:1 turndown and a 985 lb operating weight.

Natural gasHeating-only

Frequently asked questions

What gas connection does each use?

1-1/4" NPT-F on the N1500MFD and 1-1/2" NPT-F on the N2000MFD, per the submittal.

Does the submittal print a turndown for these sizes?

No — the N1500/N2000 submittal prints input, output and design data but no minimum-input or turndown row; the 5:1 figure is the series claim on the product page.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate