P-K MODU-FIRE FD N2500 vs N3000

Verdict in brief

The MODU-FIRE FD N2500 and N3000 share the same 500 MBH minimum input, 2" NPT gas connection, 3"-150# flanged supply/return, 1,185 lb operating and 1,220 lb shipping weights and 357 sq. ft. heated surface; the N3000 adds 500 MBH of input and 424 MBH of output, deepens turndown from 5:1 to 6:1, grows 2" taller and moves 254.7 GPM at 20°F ΔT versus 212.3 GPM.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of P-K MODU-FIRE FD N2500 and P-K MODU-FIRE FD N3000
SpecificationP-K MODU-FIRE FD N2500P-K MODU-FIRE FD N3000
Minimum input500 MBH500 MBH
Input2,500 MBH3,000 MBH
Output2,123 MBH2,547 MBH
Efficiency (page)88 %88 %
Turndown ratio5:16:1
Main gas connection2" NPT-F2" NPT-F
Boiler supply / return3"-150# ANSI flange (supply F / return M)3"-150# ANSI flange (supply F / return M)
Operating weight1,185 lb1,185 lb
Shipping weight1,220 lb1,220 lb
Boiler water content12.6 gal12.6 gal
Boiler HP65.778.9
Heated wet surface area357 sq. ft.357 sq. ft.
Flow rate @ 20°F ΔT212.3 GPM254.7 GPM
Combustion air inlet8" dia. stub (10" with optional air-intake adapter)8" dia. stub (10" with optional air-intake adapter)
Exhaust vent10"10"
Shipping width32 in32 in
Shipping length54 in54 in
Shipping height68 in70 in

What actually separates them

P-K's submittal prints the N2500MFD at 2,500,000 BTU/hr input / 2,123,000 BTU/hr output with a 500,000 BTU/hr minimum and 5:1 turndown, and the N3000MFD at 3,000,000 / 2,547,000 with the same 500,000 BTU/hr minimum and 6:1 turndown — the deepest in the line.

Connections and design data are shared: 2" NPT-F gas, 3"-150# ANSI flanged supply/return, 160 psig maximum pressure, 250°F maximum allowable temperature, 220°F maximum setpoint, 65.7 and 78.9 boiler HP and 357 sq. ft. of heated wet surface.

The physical difference is small — 1,185 lb operating weight on both, with the N3000's shipping box 2" taller at 54" × 32" × 70" — but flow rises from 212.3 to 254.7 GPM at 20°F ΔT, so near-boiler piping and pump selection must follow the larger unit. Both require Category II or IV venting.

Patterson-Kelley

P-K MODU-FIRE FD N2500

CurrentCanadian status unknown
Input
500–2500 MBH
Output (max)
2,123 MBH
AFUE

The P-K MODU-FIRE FD N2500 is a forced-draft non-condensing commercial boiler rated 2500 MBH input and 2123 MBH output in Patterson-Kelley's published submittal, with 5:1 turndown, a 500 MBH minimum input and a 1185 lb operating weight.

Natural gasHeating-only

Patterson-Kelley

P-K MODU-FIRE FD N3000

CurrentCanadian status unknown
Input
500–3000 MBH
Output (max)
2,547 MBH
AFUE

The P-K MODU-FIRE FD N3000 is a forced-draft non-condensing commercial boiler rated 3000 MBH input and 2547 MBH output in Patterson-Kelley's published submittal, with 6:1 turndown, a 500 MBH minimum input and a 1185 lb operating weight.

Natural gasHeating-only

Frequently asked questions

Which has deeper turndown?

The N3000MFD at 6:1 versus 5:1 on the N2500MFD, per the submittal.

Are the water connections flanged?

Yes — both print 3"-150# ANSI flanged supply and return connections.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate