Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Crown Phantom II PHTM2120H vs PHTM2150H

Verdict in brief

The PHTM2120H and PHTM2150H are both 95.0% AFUE Phantom II heat-only boilers, but the 2150H moves to the deeper 20.4 × 17.8 × 29.8 inch cabinet: input rises from 13.6–120 to 20–150 MBH, DOE capacity from 112 to 141 MBH and net AHRI from 97 to 123 MBH, with shipping weight growing from 112 to 132 lb and the minimum fire from 13.6 to 20 MBH.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Crown Phantom II PHTM2120H and Crown Phantom II PHTM2150H
SpecificationCrown Phantom II PHTM2120HCrown Phantom II PHTM2150H
Input, minimum13.6 MBH20 MBH
Input, maximum120 MBH150 MBH
DOE heating capacity112 MBH141 MBH
Net AHRI water rating97 MBH123 MBH
Efficiency (AFUE)95 %95 %
Turndown ratio10:110:1
Boiler water content0.75 gal1 gal
Shipping weight112 lb132 lb
Dimensions (D × W × H)16.3" × 17.8" × 29.8"20.4" × 17.8" × 29.8"
Max. equivalent vent length, 2"70 ft70 ft
Max. equivalent vent length, 3"135 ft135 ft
Heating water connections1" sweat1" sweat
Gas connection1/2" MPT1/2" MPT
Maximum allowable working pressure (MAWP)50 psig50 psig
Electrical120 VAC, 60 Hz, 1-phase, 1.8 A120 VAC, 60 Hz, 1-phase, 1.8 A
FuelNatural gas or LPNatural gas or LP
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater

What actually separates them

Both are stainless steel condensing, direct-vent Phantom II heat-only boilers on the gas-adaptive 'PHTM II' control with 10:1 modulation, 2"/3" venting to 70/135 ft, 1" sweat supply/return, 1/2" MPT gas and 50 psig MAWP at 95.0% AFUE.

The 2150H lifts input to 20–150 MBH for 141 MBH DOE heating capacity and a 123 MBH net AHRI water rating, against the 2120H's 112 MBH DOE and 97 MBH net over a 13.6–120 MBH input range.

The cabinet is the visible step: the 2150H measures 20.4 × 17.8 × 29.8 inches (D × W × H) against the 2120H's 16.3-inch depth, ships at 132 lb against 112 lb, and holds 1.0 gal against 0.75 gal. Its higher 20 MBH minimum fire means low-load homes will modulate more steadily on the 2120H.

CurrentCanadian status unknown
Input
13.6–120 MBH
Output (max)
AFUE
95 %

The Crown Phantom II PHTM2120H fires 13.6 to 120 MBH at 95.0% AFUE with 112 MBH DOE heating capacity and a 97 MBH net AHRI rating, keeping the same 16.3 × 17.8 × 29.8 inch cabinet as the 2080H at 112 lb shipping.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
20–150 MBH
Output (max)
AFUE
95 %

The Crown Phantom II PHTM2150H fires 20 to 150 MBH at 95.0% AFUE with 141 MBH DOE heating capacity and a 123 MBH net AHRI rating, stepping to the deeper 20.4-inch cabinet at 132 lb shipping.

Natural gasPropaneHeating-only

Frequently asked questions

What cabinet does the PHTM2150H use?

The large cabinet — 20.4 × 17.8 × 29.8 inches (D × W × H), shared with the PHTM2180H — against the 2120H's 16.3-inch-deep small cabinet.

What does the PHTM2150H add over the PHTM2120H?

Input rises from 13.6–120 to 20–150 MBH, DOE capacity from 112 to 141 MBH, net AHRI from 97 to 123 MBH and shipping weight from 112 to 132 lb.

Is the 20 MBH minimum fire a drawback?

It depends on the load: a home whose design-day load sits far below the 2150H's range will spend more time at minimum fire, which favours the 2120H's 13.6 MBH floor.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate