Triangle Tube Instinct 155S vs 199S (wall)

Verdict in brief

The Instinct 155S and 199S are the two largest wall solos, and the 199S trades on capacity only: it fires to 199,000 BTU/h against 155,000 BTU/h with 184 MBH DOE capacity against 142 MBH. The costs are a higher minimum fire (24.875 against 19.375 MBH), 10 extra pounds (105 lb against 95 lb) and the loss of the printed 2" vent option, which only the 155S retains at 33 ft.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Triangle Tube Instinct 155S (wall) and Triangle Tube Instinct 199S (wall)
SpecificationTriangle Tube Instinct 155S (wall)Triangle Tube Instinct 199S (wall)
Heating input, minimum19.375 MBH24.875 MBH
Heating input, maximum155 MBH199 MBH
Efficiency (AFUE)95 %95 %
DOE heating capacity142 MBH184 MBH
Net AHRI rating123 MBH159 MBH
Turndown ratio8:18:1
Water volume3 gal4 gal
Weight95 lb105 lb
Maximum vent length, 3"100 ft100 ft

What actually separates them

Both models share the 21.75" x 26" x 16.5" wall cabinet, 95% AFUE, 8:1 turndown, 1" MNPT supply/return connections and 3/4" MNPT gas connection. The 199S holds 4 gallons of water against the 155S's 3 gallons and weighs 105 lb against 95 lb.

The 199S's ceiling of 199,000 BTU/h (184 MBH DOE, 159 MBH net AHRI) leaves the 155S at 155,000 BTU/h (142 MBH DOE, 123 MBH net AHRI). Because minimum fire rises from 19.375 to 24.875 MBH, the 155S keeps better low-load behaviour, and both sizes modulate well below the full 8:1 turndown claim only when the load fits their range.

Venting is the practical difference: the product page prints a 33 ft 2" maximum for the 155S but no 2" run at all for the 199S, whose only printed allowance is 100 ft in 3". Both sizes are documented for the installed base after the November 3, 2025 cessation and neither is on the February 2025 recall.

DiscontinuedHistorically in Canada
Input
19.375–155 MBH
Output (max)
AFUE
95 %

The Instinct 155S (INS155S) is the mid-size Instinct wall solo: 19.375 to 155 MBH of input at 95% AFUE with 8:1 turndown, rated 142 MBH DOE capacity and 123 MBH net AHRI. Discontinued with the November 3, 2025 cessation.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
24.875–199 MBH
Output (max)
AFUE
95 %

The Instinct 199S (INS199S) is the largest Instinct wall solo: 24.875 to 199 MBH of input at 95% AFUE with 8:1 turndown, rated 184 MBH DOE capacity — the heating-only ceiling of the Instinct wall line. Discontinued with the November 3, 2025 cessation.

Natural gasPropaneHeating-only

Frequently asked questions

Can the Instinct 199S be vented in 2" pipe?

The product page prints no 2" maximum run for the 199S — its 2" column is blank — while the 155S lists 33 ft. Both allow 100 ft in 3", and the vent supplement 241576 governs the installed run.

How much bigger is the 199S than the 155S?

10 lb heavier (105 lb against 95 lb) and one more gallon of water (4 against 3), in the same 21.75" x 26" x 16.5" cabinet. Only the firing range and venting table really differ.

When does the 199S make sense over the 155S?

When the heat-loss calculation approaches or exceeds the 155S's 155,000 BTU/h ceiling on a design day. Below that, the 155S's lower minimum fire and 2" venting option keep it the more flexible boiler.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate