Utica MGB-150K vs MGB-175K

Verdict in brief

The MGB-150K and MGB-175K are adjacent sizes in the current MGB-K cast-iron water line — both non-condensing atmospheric boilers at 84% AFUE with 1¼" NPT water connections and a Hydrolevel control with built-in LWCO. The MGB-175K fires 175 MBH against 149 MBH, printing 147 MBH of heating capacity (125) and a 128 MBH net AHRI water rating (109); the flue steps from 6" to 7" and the cabinet changes from 19 × 32⅛ × 27¼ in to 21⅞ × 32⅛ × 27¼ in, with 6 burners against 5 and a shipping weight of 385 lb against 335 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Utica MGB-150K and Utica MGB-175K
SpecificationUtica MGB-150KUtica MGB-175K
Input149 MBH175 MBH
Heating capacity125 MBH147 MBH
Net AHRI water rating109 MBH128 MBH
AFUE84 %84 %
Boiler water content3.2 gal3.7 gal
Flue connection6"7"
Burners56
Dimensions (W x H x D)19 × 32⅛ × 27¼21⅞ × 32⅛ × 27¼
Shipping weight335 lb385 lb

What actually separates them

Both models are MGB-K cast-iron water boilers at 84% AFUE — a non-condensing, atmospheric chimney-vented design with an integral low-profile draft hood, motorized vent damper, dry-leg cast-iron heat exchanger and a Hydrolevel control with built-in low water cut-off. Neither modulates: input is fixed.

The brochure table prints 149 MBH input with 125 MBH heating capacity and a 109 MBH net AHRI water rating on the MGB-150K, against 175 MBH, 147 MBH and 128 MBH on the MGB-175K. Boiler water content rises from 3.2 to 3.7 gal and burner count from 5 to 6.

Installation details move with size: the flue steps from 6" to 7", both take ½" NPT gas, and the cabinet changes from 19 × 32⅛ × 27¼ in to 21⅞ × 32⅛ × 27¼ in; shipping weight rises from 335 to 385 lb. A licensed heat-loss calculation should decide between the two — extra capacity beyond the design load only shortens run times in a fixed-input boiler.

Utica Boilers

Utica MGB-150K

CurrentSold in Canada
Input
Output (max)
AFUE
84 %

The Utica MGB-150K is a size in the current MGB-K cast-iron water line: 149 MBH fixed input, 125 MBH heating capacity, a 109 MBH net AHRI water rating and 84% AFUE, with atmospheric chimney venting, a 6" flue and 5 burners. Its card carries the official 'Current' and 'Available in Canada' tags.

Natural gasPropaneHeating-only

Utica Boilers

Utica MGB-175K

CurrentSold in Canada
Input
Output (max)
AFUE
84 %

The Utica MGB-175K is a size in the current MGB-K cast-iron water line: 175 MBH fixed input, 147 MBH heating capacity, a 128 MBH net AHRI water rating and 84% AFUE, with atmospheric chimney venting, a 7" flue and 6 burners. Its card carries the official 'Current' and 'Available in Canada' tags.

Natural gasPropaneHeating-only

Frequently asked questions

What does the MGB-175K add over the MGB-150K?

175 MBH input against 149 MBH, 147 MBH heating capacity against 125 MBH, and a 128 MBH net AHRI water rating against 109 MBH, per the official MGB-K brochure table.

Are both boilers condensing?

No — every MGB-K is a non-condensing cast-iron boiler at 84% AFUE with atmospheric chimney venting, an integral draft hood and a motorized vent damper.

Which size should a project choose?

Size from a licensed heat-loss calculation: the MGB-150K suits loads that fit its 125 MBH heating capacity, while the MGB-175K covers loads approaching 147 MBH. Neither modulates, so oversizing shows up as shorter run cycles.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate