Utica MGB-150K

The Utica MGB-150K is a size in the current MGB-K cast-iron water line: 149 MBH fixed input, 125 MBH heating capacity, a 109 MBH net AHRI water rating and 84% AFUE, with atmospheric chimney venting, a 6" flue and 5 burners. Its card carries the official 'Current' and 'Available in Canada' tags.

CurrentSold in Canada

Key figures

Max input
Max CSA output
AFUE
84 %
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Utica MGB-150K in practice

The MGB-150K is one of the seven MGB-K ('MGB Series') sizes Utica prints: 149 MBH fixed input for 125 MBH heating capacity and a 109 MBH net AHRI water rating at 84% AFUE. The official brochure table (PN 240013193 Rev. 04/15/26) prints 3.2 gal of boiler water, a 6" flue connection, 5 burners, 19 × 32⅛ × 27¼ in cabinet dimensions and a 335 lb shipping weight for this size.

It is a non-condensing cast-iron design with dry-leg end sections, atmospheric chimney venting through an integral low-profile draft hood and motorized vent damper, a pull-out burner drawer with removable burner tube tray for service, and flame roll-out and blocked-vent safety shut-offs. Water return and supply are 1¼" NPT with ½" NPT; the boiler is wired 120 V AC 60 Hz at under 12 A.

The internal Hydrolevel control adjusts water temperature to heating-system demand with a built-in low water cut-off; the IOM prints indicator-light diagnostics rather than numeric fault codes. Utica prints a 20-year non-prorated limited residential warranty plus 5-year parts, and the official footnote derates input 4% per 1,000 ft above 2,000 ft. The official category card carries the 'Current' and 'Available in Canada' tags; gas, venting and combustion work belongs with a licensed contractor.

Best suited to

  • Chimney-vented homes whose heat-loss calculation fits 149 MBH of fixed input
  • Owners who want cast-iron longevity with a simple non-modulating control platform
  • Canadian projects where the official 'Available in Canada' category tag applies

Applicability and support

Model number
MGB-150K
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Utica Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.

Utica MGB-150K specifications
SpecificationValueNote
Input
Input149 MBHFixed input in MBH as printed in the official MGB-K brochure table (PN 240013193 Rev. 04/15/26); the MGB-K does not modulate.
Output
Heating capacity125 MBHHeating capacity in MBH as printed in the official MGB-K brochure table.
Net AHRI water rating109 MBHNet AHRI water rating in MBH as printed in the official MGB-K brochure table.
Efficiency
AFUE84 %84% AFUE printed for every MGB-K size in the official brochure table.
Venting and air
Flue connection6"Flue diameter as printed in the official brochure table; atmospheric chimney vent with integral low-profile draft hood and motorized vent damper.
VentingAtmospheric chimney vent — integral low-profile draft hood (draft diverter) with motorized vent damper2021 DOE standard compliant; the integral draft diverter reduces installation height by up to 30 in compared with external draft hoods, per the product page.
Physical and connections
Boiler water content3.2 galBoiler water content in gallons as printed in the official brochure table.
Burners5Number of burners as printed in the official brochure table; stainless steel burners with a pull-out burner drawer and removable burner tube tray for service.
Dimensions (W x H x D)19 × 32⅛ × 27¼Cabinet dimensions in inches as printed in the official brochure table.
Shipping weight335 lbShipping weight in pounds as printed in the official brochure table.
Heat exchangerCast iron with dry-leg end sectionsAs printed on the product page.
Operating limits and other
ConnectionsWater return/supply 1¼" NPT; gas ½" NPT; 120 V AC 60 Hz, <12 AWater and gas piping can exit the left or right side of the boiler; ¾" NPT gas applies to the MGB-205K/235K.
ControlInternal Hydrolevel operating control with built-in low water cut-off (LWCO) and diagnostic indicator lightsThe control adjusts water temperature to heating-system demand; the IOM prints indicator-light diagnostics rather than numeric fault codes.
Warranty20-year non-prorated limited residential warranty plus 5-year partsAs printed for the MGB-K line.
AltitudeReduce input 4% per 1,000 ft above 2,000 ftOfficial brochure footnote; high-altitude orifice kits are listed as options.

Frequently asked questions

What are the MGB-150K's ratings?

149 MBH fixed input, 125 MBH heating capacity, a 109 MBH net AHRI water rating and 84% AFUE, per the official MGB-K brochure table.

Is the MGB-150K a condensing boiler?

No — the MGB-K is a non-condensing cast-iron boiler at 84% AFUE with atmospheric chimney venting, an integral draft hood and a motorized vent damper.

Does the MGB-150K modulate?

No — input is fixed. The MGB-K uses a single firing rate with a Hydrolevel control that adjusts water temperature to system demand.

Questions about the Utica MGB-150K?