Utica MGB-175K vs MGB-205K

Verdict in brief

The MGB-175K and MGB-205K are adjacent sizes in the current MGB-K cast-iron water line — both non-condensing atmospheric boilers at 84% AFUE with 1¼" NPT water connections and a Hydrolevel control with built-in LWCO. The MGB-205K fires 205 MBH against 175 MBH, printing 172 MBH of heating capacity (147) and a 150 MBH net AHRI water rating (128); both use a 7" flue connection and the cabinet changes from 21⅞ × 32⅛ × 27¼ in to 27½ × 32⅛ × 27¾ in, with 7 burners against 6 and a shipping weight of 420 lb against 385 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Utica MGB-175K and Utica MGB-205K
SpecificationUtica MGB-175KUtica MGB-205K
Input175 MBH205 MBH
Heating capacity147 MBH172 MBH
Net AHRI water rating128 MBH150 MBH
AFUE84 %84 %
Boiler water content3.7 gal4.1 gal
Flue connection7"7"
Burners67
Dimensions (W x H x D)21⅞ × 32⅛ × 27¼27½ × 32⅛ × 27¾
Shipping weight385 lb420 lb

What actually separates them

Both models are MGB-K cast-iron water boilers at 84% AFUE — a non-condensing, atmospheric chimney-vented design with an integral low-profile draft hood, motorized vent damper, dry-leg cast-iron heat exchanger and a Hydrolevel control with built-in low water cut-off. Neither modulates: input is fixed.

The brochure table prints 175 MBH input with 147 MBH heating capacity and a 128 MBH net AHRI water rating on the MGB-175K, against 205 MBH, 172 MBH and 150 MBH on the MGB-205K. Boiler water content rises from 3.7 to 4.1 gal and burner count from 6 to 7.

Installation details move with size: both use a 7" flue connection, gas steps from ½" NPT to ¾" NPT, and the cabinet changes from 21⅞ × 32⅛ × 27¼ in to 27½ × 32⅛ × 27¾ in; shipping weight rises from 385 to 420 lb. A licensed heat-loss calculation should decide between the two — extra capacity beyond the design load only shortens run times in a fixed-input boiler.

Utica Boilers

Utica MGB-175K

CurrentSold in Canada
Input
—
Output (max)
—
AFUE
84 %

The Utica MGB-175K is a size in the current MGB-K cast-iron water line: 175 MBH fixed input, 147 MBH heating capacity, a 128 MBH net AHRI water rating and 84% AFUE, with atmospheric chimney venting, a 7" flue and 6 burners. Its card carries the official 'Current' and 'Available in Canada' tags.

Natural gasPropaneHeating-only

Utica Boilers

Utica MGB-205K

CurrentSold in Canada
Input
—
Output (max)
—
AFUE
84 %

The Utica MGB-205K is a size in the current MGB-K cast-iron water line: 205 MBH fixed input, 172 MBH heating capacity, a 150 MBH net AHRI water rating and 84% AFUE, with atmospheric chimney venting, a 7" flue and 7 burners. Its card carries the official 'Current' and 'Available in Canada' tags.

Natural gasPropaneHeating-only

Frequently asked questions

What does the MGB-205K add over the MGB-175K?

205 MBH input against 175 MBH, 172 MBH heating capacity against 147 MBH, and a 150 MBH net AHRI water rating against 128 MBH, per the official MGB-K brochure table.

Are both boilers condensing?

No — every MGB-K is a non-condensing cast-iron boiler at 84% AFUE with atmospheric chimney venting, an integral draft hood and a motorized vent damper.

Which size should a project choose?

Size from a licensed heat-loss calculation: the MGB-175K suits loads that fit its 147 MBH heating capacity, while the MGB-205K covers loads approaching 172 MBH. Neither modulates, so oversizing shows up as shorter run cycles.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate