- Input
- 21–125 MBH
- Output (max)
- —
- AFUE
- 95 %
The Vitodens 100-W B1HA 35, 125 is the larger heating-only model of the B1HA generation: 21 to 125 MBH natural gas input at 95.0% AFUE in the 79.4 lb (36 kg) cabinet.
Canada-wide gas boiler information · On-site service in Greater Vancouver, BC
Boilers.ca is a brand of ROMA Heating & Cooling · Licensed gas contractor LGA0202903
Comparison
Verdict in brief
The B1HA 35, 125 and B1KA 35, 125 share the same heating side — 21 to 125 MBH NG/LPG input, 20 to 116 MBH output, a 101 MBH Net AHRI rating and 95.0% AFUE — and the same cabinet. The B1KA adds on-demand DHW through a plate heat exchanger at up to 149 MBH input and a 3.5 USG/min continuous draw, and weighs 90 lb (41 kg) against the B1HA's 79.4 lb.
Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.
| Specification | Viessmann Vitodens 100-W B1HA 35, 125 | Viessmann Vitodens 100-W B1KA 35, 125 |
|---|---|---|
| CSA input, minimum (natural gas) | 21 MBH | 21 MBH |
| CSA input, maximum (natural gas) | 125 MBH | 125 MBH |
| CSA output / DOE heating capacity (natural gas) | 20-116 MBH | 20-116 MBH |
| Net AHRI rating | 101 MBH | 101 MBH |
| Efficiency (AFUE) | 95 % | 95 % |
| Weight | 79.4 lb | 90 lb |
| Boiler water content | 1.02 USG | 1.02 USG |
| Maximum operating pressure | 45 psig | 45 psig |
The heating side is identical: both fire 21-125 MBH (6.2-36.6 kW) on natural gas, 31-125 MBH on propane, with 20-116 MBH output, a 101 MBH Net AHRI rating and 95.0% AFUE. Both share the 400 x 400 x 768 mm cabinet, 1.02 USG boiler water content and 45 psig maximum operating pressure.
The difference is domestic hot water. The B1HA is heating-only and pairs with an indirect tank; the B1KA carries an integrated plate heat exchanger, diverting valve, three-speed pump, pressure bypass valve, water hammer arrester, flow and temperature sensors, and a 150 psi pressure relief valve. Its printed DHW input reaches 149 MBH (43.7 kW) with a 3.5 USG/min continuous draw at a 77°F rise and a 3.7 USG/min maximum flow.
The combi weighs 90 lb (41 kg) — 10.6 lb more than the B1HA — with a 99.2 lb (45 kg) shipping weight. Households with modest simultaneous hot-water demand can replace a boiler-and-tank pair with the B1KA; those wanting tank storage keep the B1HA plus an indirect tank.
The Vitodens 100-W B1HA 35, 125 is the larger heating-only model of the B1HA generation: 21 to 125 MBH natural gas input at 95.0% AFUE in the 79.4 lb (36 kg) cabinet.
The Vitodens 100-W B1KA 35, 125 is the combi model of the B1HA/B1KA generation: 21 to 125 MBH heating input at 95.0% AFUE plus on-demand DHW at up to 149 MBH input and a 3.5 USG/min continuous draw at a 77°F rise.
Yes — both print 21-125 MBH NG/LPG input, 20-116 MBH output, a 101 MBH Net AHRI rating and 95.0% AFUE.
A 3.5 USG/min continuous draw at a 77°F (43K) rise from a maximum 149 MBH (43.7 kW) DHW input, with a 3.7 USG/min maximum flow through the plate heat exchanger.
The combi adds the plate heat exchanger, diverting valve, pump and DHW hydraulics: 90 lb (41 kg) against 79.4 lb (36 kg) for the heating-only B1HA.
A consultation includes a heat-loss review so the size is right the first time.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.