Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Viessmann Vitodens 100-W B1HA 35, 125 vs B1KA 35, 125

Verdict in brief

The B1HA 35, 125 and B1KA 35, 125 share the same heating side — 21 to 125 MBH NG/LPG input, 20 to 116 MBH output, a 101 MBH Net AHRI rating and 95.0% AFUE — and the same cabinet. The B1KA adds on-demand DHW through a plate heat exchanger at up to 149 MBH input and a 3.5 USG/min continuous draw, and weighs 90 lb (41 kg) against the B1HA's 79.4 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Viessmann Vitodens 100-W B1HA 35, 125 and Viessmann Vitodens 100-W B1KA 35, 125
SpecificationViessmann Vitodens 100-W B1HA 35, 125Viessmann Vitodens 100-W B1KA 35, 125
CSA input, minimum (natural gas)21 MBH21 MBH
CSA input, maximum (natural gas)125 MBH125 MBH
CSA output / DOE heating capacity (natural gas)20-116 MBH20-116 MBH
Net AHRI rating101 MBH101 MBH
Efficiency (AFUE)95 %95 %
Weight79.4 lb90 lb
Boiler water content1.02 USG1.02 USG
Maximum operating pressure45 psig45 psig

What actually separates them

The heating side is identical: both fire 21-125 MBH (6.2-36.6 kW) on natural gas, 31-125 MBH on propane, with 20-116 MBH output, a 101 MBH Net AHRI rating and 95.0% AFUE. Both share the 400 x 400 x 768 mm cabinet, 1.02 USG boiler water content and 45 psig maximum operating pressure.

The difference is domestic hot water. The B1HA is heating-only and pairs with an indirect tank; the B1KA carries an integrated plate heat exchanger, diverting valve, three-speed pump, pressure bypass valve, water hammer arrester, flow and temperature sensors, and a 150 psi pressure relief valve. Its printed DHW input reaches 149 MBH (43.7 kW) with a 3.5 USG/min continuous draw at a 77°F rise and a 3.7 USG/min maximum flow.

The combi weighs 90 lb (41 kg) — 10.6 lb more than the B1HA — with a 99.2 lb (45 kg) shipping weight. Households with modest simultaneous hot-water demand can replace a boiler-and-tank pair with the B1KA; those wanting tank storage keep the B1HA plus an indirect tank.

DiscontinuedHistorically in Canada
Input
21–125 MBH
Output (max)
—
AFUE
95 %

The Vitodens 100-W B1KA 35, 125 is the combi model of the B1HA/B1KA generation: 21 to 125 MBH heating input at 95.0% AFUE plus on-demand DHW at up to 149 MBH input and a 3.5 USG/min continuous draw at a 77°F rise.

Natural gasPropaneCombi

Frequently asked questions

Is the heating performance the same on both models?

Yes — both print 21-125 MBH NG/LPG input, 20-116 MBH output, a 101 MBH Net AHRI rating and 95.0% AFUE.

How much hot water does the B1KA 35, 125 deliver?

A 3.5 USG/min continuous draw at a 77°F (43K) rise from a maximum 149 MBH (43.7 kW) DHW input, with a 3.7 USG/min maximum flow through the plate heat exchanger.

Why does the B1KA weigh more?

The combi adds the plate heat exchanger, diverting valve, pump and DHW hydraulics: 90 lb (41 kg) against 79.4 lb (36 kg) for the heating-only B1HA.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate