The Vitodens 100-W B1KA 35, 125 is the combi model of the B1HA/B1KA generation: 21 to 125 MBH heating input at 95.0% AFUE plus on-demand DHW at up to 149 MBH input and a 3.5 USG/min continuous draw at a 77°F rise.
Key figures
- Max input
- 125 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 21 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Viessmann Vitodens 100-W B1KA 35, 125 in practice
The B1KA 35, 125 is the combi version of the B1HA generation: it heats at 21-125 MBH (6.2-36.6 kW) natural gas input with 20-116 MBH output at 95.0% AFUE, and adds on-demand domestic hot water through an integrated plate heat exchanger. The technical data manual prints a maximum DHW input of 149 MBH (43.7 kW) and a continuous draw of 3.5 USG/min at a 77°F (43K) rise.
The DHW side includes a built-in diverting valve, Grundfos three-speed pump, pressure bypass valve, water hammer arrester, flow sensor and temperature sensor, with a 150 psi pressure relief valve and a 150 psi maximum allowable potable-water working pressure. The combi weighs 90 lb (41 kg) — 10.6 lb more than the B1HA models — in the same 400 x 400 x 768 mm cabinet, with a 99.2 lb (45 kg) shipping weight and 1.02 USG boiler water content.
Best suited to
- Owners of existing B1KA 35/125 combis looking up printed ratings and DHW figures
- Homes wanting one wall-hung appliance for heat and on-demand hot water
- Documentation for the only combi in the B1HA/B1KA generation
Applicability and support
- Model number
- B1KA 35, 125
- Canadian availability
- historical
- Production status
- discontinued
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| CSA input, minimum (natural gas) | 21 MBH | 6.2 kW, per the technical data manual |
| CSA input, maximum (natural gas) | 125 MBH | 36.6 kW, per the technical data manual |
| CSA input (liquid propane) | 31-125 MBH | Printed LPG range from the same table. |
| Output | ||
| CSA output / DOE heating capacity (natural gas) | 20-116 MBH | 5.7-34.1 kW, based on 140°F / 120°F supply/return |
| Net AHRI rating | 101 MBH | Based on piping and pick-up allowance of 1.15. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95.0% AFUE on all B1HA/B1KA models per the technical data manual. |
| Domestic hot water | ||
| Maximum DHW input (NG and LPG) | 149 MBH | 43.7 kW; DHW production only. |
| Continuous DHW draw at 77°F rise | 3.5 USG/min | 795 L/h at a 77°F (43K) rise; maximum DHW supply temperature 140°F (60°C). |
| Maximum flow through the DHW heat exchanger | 3.7 USG/min | 840 L/h. |
| Maximum allowable working pressure (potable water) | 150 psi | Test pressure 300 psi. |
| Domestic hot water | Combi: on-demand DHW via an integrated plate heat exchanger | |
| Physical and connections | ||
| Weight | 90 lb | 41 kg |
| Shipping weight | 99.2 lb | 45 kg |
| Overall width | 400 mm | 15¾ in |
| Overall depth | 400 mm | 15¾ in |
| Overall height | 768 mm | 30¼ in |
| Operating limits and other | ||
| Fuel | Natural gas or liquid propane | NG minimum supply pressure 4 in. w.c.; LPG 10 in. w.c. |
| Boiler water content | 1.02 USG | 3.88 L. |
| Maximum operating pressure | 45 psig | 3 bar at 210°F (99°C). |
| Boiler heating supply / return | ¾ in. NPTM | Pressure relief valve ¾ in. NPTF; flue gas connection 2⅜ in (60 mm). |
Manuals
- Technical Data Manual — Vitodens 100-W B1HA Series and B1KA Combi Boiler, doc 5784 566 - 125784 566 - 12 · 2025-04
- Installation and Service Instructions — Vitodens 100-W B1HA/B1KA, rev 2222 · 2025-08
- Technical Data Manual — Vitodens 100-W WB1A Series, doc 5347 963 v1.15347 963 v1.1 · 2007-10
- Technical Data Manual — Vitodens 100-W WB1B Series, doc 5369 277 v1.55369 277 v1.5 · 2010-01
Alerts documented for this model
None documented yet.
Frequently asked questions
What is the B1KA 35, 125 rated at?
21-125 MBH (6.2-36.6 kW) heating input at 95.0% AFUE, with 20-116 MBH output and a 101 MBH Net AHRI rating. DHW production runs at up to 149 MBH (43.7 kW) input.
How much hot water does the B1KA 35, 125 deliver?
A 3.5 USG/min (795 L/h) continuous draw at a 77°F (43K) rise, with a maximum DHW supply temperature of 140°F (60°C) and a 3.7 USG/min maximum flow through the plate heat exchanger.
How does the B1KA 35, 125 differ from the B1HA 35, 125?
The heating side is the same; the B1KA adds on-demand DHW through a plate heat exchanger and weighs 90 lb (41 kg) against the B1HA's 79.4 lb.
Questions about the Viessmann Vitodens 100-W B1KA 35, 125?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- Viessmann Vitodens 100-W B1HA 35, 125 vs B1KA 35, 125Comparison
- Viessmann Vitodens 100-W B1HA 26, 94Same series
- Viessmann Vitodens 100-W B1HA 35, 125Same series
- Viessmann Vitodens 100-W WB1A 8-24Same series
- Viessmann Vitodens 100-W WB1A 8-30Same series
- Viessmann Vitodens 100-W WB1B 26Same series
- Viessmann Vitodens 100-W WB1B 35Same series
- Vitodens 100-W (legacy B1HA / B1KA and earlier) series hub
- Buying guide
Sources and verification
- Technical Data Manual — Vitodens 100-W B1HA Series and B1KA Combi Boiler, doc 5784 566 - 12 · 5784 566 - 12 · accessed September 9, 2026
- Viessmann Canada — Historic manuals · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.