Viessmann · Vitodens 100-W (legacy B1HA / B1KA and earlier)

Viessmann Vitodens 100-W B1KA 35, 125

The Vitodens 100-W B1KA 35, 125 is the combi model of the B1HA/B1KA generation: 21 to 125 MBH heating input at 95.0% AFUE plus on-demand DHW at up to 149 MBH input and a 3.5 USG/min continuous draw at a 77°F rise.

DiscontinuedHistorically in Canada

Key figures

Max input
125 MBH
Max CSA output
—
AFUE
95 %
Min input
21 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Viessmann Vitodens 100-W B1KA 35, 125 in practice

The B1KA 35, 125 is the combi version of the B1HA generation: it heats at 21-125 MBH (6.2-36.6 kW) natural gas input with 20-116 MBH output at 95.0% AFUE, and adds on-demand domestic hot water through an integrated plate heat exchanger. The technical data manual prints a maximum DHW input of 149 MBH (43.7 kW) and a continuous draw of 3.5 USG/min at a 77°F (43K) rise.

The DHW side includes a built-in diverting valve, Grundfos three-speed pump, pressure bypass valve, water hammer arrester, flow sensor and temperature sensor, with a 150 psi pressure relief valve and a 150 psi maximum allowable potable-water working pressure. The combi weighs 90 lb (41 kg) — 10.6 lb more than the B1HA models — in the same 400 x 400 x 768 mm cabinet, with a 99.2 lb (45 kg) shipping weight and 1.02 USG boiler water content.

Best suited to

  • Owners of existing B1KA 35/125 combis looking up printed ratings and DHW figures
  • Homes wanting one wall-hung appliance for heat and on-demand hot water
  • Documentation for the only combi in the B1HA/B1KA generation

Applicability and support

Model number
B1KA 35, 125
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.

Viessmann Vitodens 100-W B1KA 35, 125 specifications
SpecificationValueNote
Input
CSA input, minimum (natural gas)21 MBH6.2 kW, per the technical data manual
CSA input, maximum (natural gas)125 MBH36.6 kW, per the technical data manual
CSA input (liquid propane)31-125 MBHPrinted LPG range from the same table.
Output
CSA output / DOE heating capacity (natural gas)20-116 MBH5.7-34.1 kW, based on 140°F / 120°F supply/return
Net AHRI rating101 MBHBased on piping and pick-up allowance of 1.15.
Efficiency
Efficiency (AFUE)95 %95.0% AFUE on all B1HA/B1KA models per the technical data manual.
Domestic hot water
Maximum DHW input (NG and LPG)149 MBH43.7 kW; DHW production only.
Continuous DHW draw at 77°F rise3.5 USG/min795 L/h at a 77°F (43K) rise; maximum DHW supply temperature 140°F (60°C).
Maximum flow through the DHW heat exchanger3.7 USG/min840 L/h.
Maximum allowable working pressure (potable water)150 psiTest pressure 300 psi.
Domestic hot waterCombi: on-demand DHW via an integrated plate heat exchanger
Physical and connections
Weight90 lb41 kg
Shipping weight99.2 lb45 kg
Overall width400 mm15¾ in
Overall depth400 mm15¾ in
Overall height768 mm30¼ in
Operating limits and other
FuelNatural gas or liquid propaneNG minimum supply pressure 4 in. w.c.; LPG 10 in. w.c.
Boiler water content1.02 USG3.88 L.
Maximum operating pressure45 psig3 bar at 210°F (99°C).
Boiler heating supply / return¾ in. NPTMPressure relief valve ¾ in. NPTF; flue gas connection 2⅜ in (60 mm).

Frequently asked questions

What is the B1KA 35, 125 rated at?

21-125 MBH (6.2-36.6 kW) heating input at 95.0% AFUE, with 20-116 MBH output and a 101 MBH Net AHRI rating. DHW production runs at up to 149 MBH (43.7 kW) input.

How much hot water does the B1KA 35, 125 deliver?

A 3.5 USG/min (795 L/h) continuous draw at a 77°F (43K) rise, with a maximum DHW supply temperature of 140°F (60°C) and a 3.7 USG/min maximum flow through the plate heat exchanger.

How does the B1KA 35, 125 differ from the B1HA 35, 125?

The heating side is the same; the B1KA adds on-demand DHW through a plate heat exchanger and weighs 90 lb (41 kg) against the B1HA's 79.4 lb.

Questions about the Viessmann Vitodens 100-W B1KA 35, 125?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate