Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Viessmann Vitodens 200-W B2HA-311 vs B2HA-352

Verdict in brief

The B2HA-311 and B2HA-352 are near-identical models of the high-input Vitodens 200-W line: the same 71,000 BTU (21 kW) minimum fire, the same 194 lb (88 kg) cabinet, and the same printed 94.5% thermal-efficiency row (ANSI Z21,13/CSA 4.9). The 352 exists purely for headroom — 352,000 BTU (103 kW) maximum against the 311's 311,000 BTU (91 kW) — so the heat-loss calculation alone decides between them.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Viessmann Vitodens 200-W B2HA-311 and Viessmann Vitodens 200-W B2HA-352
SpecificationViessmann Vitodens 200-W B2HA-311Viessmann Vitodens 200-W B2HA-352
Input, minimum (natural gas)71 MBH71 MBH
Input, maximum (natural gas)311 MBH352 MBH
Thermal efficiency (ANSI Z21,13/CSA 4.9)94.5 %94.5 %
Weight194 lb194 lb
Width19 in19 in
Depth21 in21 in
Height43.5 in43.5 in

What actually separates them

The B2HA-311 and B2HA-352 share every printed specification except maximum input: both fire from a 71,000 BTU (21 kW) minimum, both weigh 194 lb (88 kg) in the 19 x 21 x 43.5 inch (480 x 530 x 1105 mm) wall-hung cabinet, and the page prints a 94.5% thermal-efficiency row (ANSI Z21,13/CSA 4.9) for both.

Maximum input is the only separator: 311,000 BTU (91 kW) for the 311 against 352,000 BTU (103 kW) for the 352. Because minimum fire is identical, the larger model costs nothing in low-load behaviour — the extra 41 MBH is pure headroom at the top of the range.

Both are gas-fired condensing boilers with the MatriX cylinder burner and Inox-Radial stainless steel heat exchanger, on natural gas or liquid propane with no fuel-conversion kit required. The page's marketing copy cites an 'up to 95% AFUE rating' separately from the printed spec rows; Boilers.ca keeps the printed rows.

CurrentSold in Canada
Input
71–311 MBH
Output (max)
AFUE

The Vitodens 200-W B2HA-311 is the second size of Viessmann Canada's high-input B2HA line: 71,000 to 311,000 BTU (21 to 91 kW) of input in the 194 lb wall-hung condensing boiler, with a printed thermal-efficiency row (ANSI Z21,13/CSA 4.9) of 94.5%.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
71–352 MBH
Output (max)
AFUE

The Vitodens 200-W B2HA-352 is the largest model in the 194 lb B2HA cabinet: 71,000 to 352,000 BTU (21 to 103 kW) of input at a printed 94.5% thermal-efficiency row (ANSI Z21,13/CSA 4.9), for the biggest loads that still fit one wall-hung boiler.

Natural gasPropaneHeating-only

Frequently asked questions

What is the difference between the B2HA-311 and the B2HA-352?

Only the maximum input: 311,000 BTU (91 kW) on the 311 versus 352,000 BTU (103 kW) on the 352. Minimum fire (71,000 BTU), weight (194 lb), cabinet and the printed 94.5% thermal-efficiency row are identical.

Are the two models the same physical size?

Yes. Both weigh 194 lb (88 kg) and measure 19 x 21 x 43.5 inches (480 x 530 x 1105 mm), per the Canadian product page.

Which of the two should I choose?

Follow the heat-loss calculation: if the load stays below roughly 311 MBH the 311 is sufficient; if it approaches 352 MBH, the 352 adds headroom with no footprint penalty and no change to minimum fire.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate