Viessmann Vitodens 200-W B2HA-352 vs B2HA-399

Verdict in brief

Stepping from the B2HA-352 to the B2HA-399 raises the maximum input from 352,000 to 399,000 BTU (103 to 117 kW) but changes the boiler's character: the minimum fire climbs from 71,000 to 113,000 BTU (21 to 33 kW), the cabinet grows to the 298 lb (135 kg), 23.5 x 27 x 44.5-inch chassis, and the printed efficiency row drops from 94.5% to 93.9% thermal efficiency (ANSI Z21,13/CSA 4.9).

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Viessmann Vitodens 200-W B2HA-352 and Viessmann Vitodens 200-W B2HA-399
SpecificationViessmann Vitodens 200-W B2HA-352Viessmann Vitodens 200-W B2HA-399
Input, minimum (natural gas)71 MBH113 MBH
Input, maximum (natural gas)352 MBH399 MBH
Thermal efficiency (ANSI Z21,13/CSA 4.9)94.5 %93.9 %
Weight194 lb298 lb
Width19 in23.5 in
Depth21 in27 in
Height43.5 in44.5 in

What actually separates them

The B2HA-352 is the top model of the B2HA mid chassis; the B2HA-399 opens the large chassis. Maximum input rises from 352,000 BTU (103 kW) to 399,000 BTU (117 kW), but the minimum fire also rises — 71,000 BTU (21 kW) on the 352 against 113,000 BTU (33 kW) on the 399 — so a low-load home would see the 399 idle higher before it can modulate down.

The physical step is real: weight goes from 194 lb (88 kg) to 298 lb (135 kg), and the cabinet grows from 19 x 21 x 43.5 inches to 23.5 x 27 x 44.5 inches (480 x 530 x 1105 mm to 600 x 689 x 1128 mm). The wall, doorways and lifting plan all change.

The printed efficiency rows also differ: 94.5% thermal efficiency (ANSI Z21,13/CSA 4.9) for the 352 against 93.9% for the 399, with page marketing copy separately citing an 'up to 95% AFUE rating'. The 399 earns its place only when the heat-loss calculation genuinely approaches its ceiling.

CurrentSold in Canada
Input
71–352 MBH
Output (max)
AFUE

The Vitodens 200-W B2HA-352 is the largest model in the 194 lb B2HA cabinet: 71,000 to 352,000 BTU (21 to 103 kW) of input at a printed 94.5% thermal-efficiency row (ANSI Z21,13/CSA 4.9), for the biggest loads that still fit one wall-hung boiler.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
113–399 MBH
Output (max)
AFUE

The Vitodens 200-W B2HA-399 opens the larger B2HA chassis: 113,000 to 399,000 BTU (33 to 117 kW) of input in the 298 lb wall-hung condensing boiler, with a printed thermal-efficiency row (ANSI Z21,13/CSA 4.9) of 93.9%.

Natural gasPropaneHeating-only

Frequently asked questions

How much bigger is the B2HA-399 than the B2HA-352?

Weight rises from 194 lb (88 kg) to 298 lb (135 kg), and the cabinet grows from 19 x 21 x 43.5 inches to 23.5 x 27 x 44.5 inches, per Viessmann Canada.

What changes in firing behaviour between these models?

Maximum input rises from 352,000 to 399,000 BTU, but minimum fire also rises from 71,000 to 113,000 BTU, so the 399 idles at a higher floor in low-load conditions.

Why is the 399's printed efficiency row lower than the 352's?

The page prints 93.9% thermal efficiency (ANSI Z21,13/CSA 4.9) for the B2HA-399 against 94.5% for the B2HA-352 — the figures as printed, separate from the page's 'up to 95% AFUE' marketing claim.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate