Viessmann Vitocrossal 200 CI2-399 vs CI2-500

Verdict in brief

The CI2-399 and CI2-500 are the two smallest Vitocrossal 200 CI2 models and are twins below the top of the range: both fire from a 50 MBH (14.7 kW) minimum input, both print 97% combustion efficiency, and both weigh 789 lb (358 kg) with 29 USG of water content. The 500 adds 101 MBH of ceiling — 500 against 399 MBH maximum — which is the only published difference between them.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Viessmann Vitocrossal 200 CI2-399 and Viessmann Vitocrossal 200 CI2-500
SpecificationViessmann Vitocrossal 200 CI2-399Viessmann Vitocrossal 200 CI2-500
Rated input, minimum (natural gas/LPG)50 MBH50 MBH
Rated input, maximum (natural gas/LPG)399 MBH500 MBH
Combustion efficiency97 %97 %
Weight789 lb789 lb
Boiler water content29 USG29 USG

What actually separates them

Both models open the Vitocrossal 200 CI2 range on the same floor-standing chassis. Viessmann Canada prints a 50,000 BTU (14.7 kW) minimum input for each — one NG/LPG rated-input figure covering both fuels — and both step out of the entry group with the same 789 lb (358 kg) weight and 29 USG of boiler water content.

Maximum input is the only separator: 399,000 BTU (117 kW) on the CI2-399 against 500,000 BTU (147 kW) on the CI2-500. Because minimum fire, efficiency (97% combustion efficiency on both) and chassis are identical, the 500's extra 101 MBH is pure headroom at the top of the range with no low-load penalty.

Both models share the Inox-Crossal stainless steel heat exchanger, MatriX cylinder burner with Lambda PrO₂ trim and the Viessmann One Base control platform, and both use the 4-inch flue and combustion-air collars of the entry chassis. The choice between them is the design load calculation: below roughly 399 MBH the smaller unit is enough; between 399 and 500 MBH the 500 covers the plant without a larger boiler.

CurrentSold in Canada
Input
50–399 MBH
Output (max)
—
AFUE
—

The Vitocrossal 200 CI2-399 is the entry size of Viessmann Canada's Vitocrossal 200 CI2 line: 50 to 399 MBH rated input (14.7 to 117 kW) at 97% combustion efficiency, weighing 789 lb (358 kg) with 29 USG of boiler water content.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
50–500 MBH
Output (max)
—
AFUE
—

The Vitocrossal 200 CI2-500 steps the top of the CI2 entry chassis to 500 MBH: 50 to 500 MBH rated input (14.7 to 147 kW) at 97% combustion efficiency, in the same 789 lb (358 kg) unit with 29 USG of boiler water content as the CI2-399.

Natural gasPropaneHeating-only

Frequently asked questions

Are the CI2-399 and CI2-500 different sizes?

No. Both weigh 789 lb (358 kg), hold 29 USG of water and fire from a 50 MBH minimum input per the printed figures; only the maximum input differs (399 vs 500 MBH).

Which of the two is more efficient?

Neither — both print 97% combustion efficiency, the highest figure in the CI2 series.

When does the CI2-500 make more sense than the CI2-399?

When the design heat load plus system demand exceeds roughly 399 MBH. Below that, the 399 delivers identical low-fire behaviour, weight and efficiency.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.