Viessmann Vitodens 100-W WB1A 8-24 vs WB1A 8-30

Verdict in brief

The WB1A 8-24 and WB1A 8-30 are the two first-generation Vitodens 100-W boilers and are physically identical: 95 lb (43 kg), 0.82 USG of water, 45 psig and the same 400 x 340 x 700 mm cabinet at 95.1% AFUE. The 8-30 simply fires higher — 100 against 80 MBH natural gas — for a 78 MBH Net I=B=R rating against 63.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Viessmann Vitodens 100-W WB1A 8-24 and Viessmann Vitodens 100-W WB1A 8-30
SpecificationViessmann Vitodens 100-W WB1A 8-24Viessmann Vitodens 100-W WB1A 8-30
CSA input, minimum (natural gas)29 MBH29 MBH
CSA input, maximum (natural gas)80 MBH100 MBH
CSA output / DOE heating capacity26-72 MBH26-90 MBH
Net I=B=R rating63 MBH78 MBH
Efficiency (AFUE)95.1 %95.1 %
Weight95 lb95 lb
Boiler water content0.82 USG0.82 USG
Maximum operating pressure45 psig45 psig

What actually separates them

Both boilers are wall-hung condensing models rated 95.1% AFUE with a 29 MBH (8.5 kW) natural gas minimum input and a 26 MBH output floor. They share the 400 x 340 x 700 mm (15.7 x 13.4 x 27.6 in) cabinet, 95 lb (43 kg) weight, 0.82 USG water content and 45 psig maximum operating pressure.

Maximum input separates them: 80 MBH (23.4 kW) on the 8-24 against 100 MBH (29.3 kW) on the 8-30, with outputs of 26-72 and 26-90 MBH and Net I=B=R ratings of 63 and 78 MBH.

The WB1A technical data manual prints natural gas ratings only; the later WB1B generation added printed propane ratings. Both models are heating-only and documented in Viessmann Canada's historic manuals.

Frequently asked questions

Are the WB1A 8-24 and 8-30 the same size?

Yes. Both weigh 95 lb (43 kg) and measure 400 x 340 x 700 mm with 0.82 USG of boiler water.

What are the firing ranges?

29-80 MBH (8.5-23.4 kW) on the 8-24 and 29-100 MBH (8.5-29.3 kW) on the 8-30, both natural gas.

Do the WB1A models run on propane?

The WB1A technical data manual prints natural-gas ratings only; the WB1B generation that followed added combined NG/LPG ratings.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.