Skip to content
Boilers.caby ROMA Heating & Cooling

Viessmann · Vitodens 100-W (legacy B1HA / B1KA and earlier)

Viessmann Vitodens 100-W WB1A 8-30

The Vitodens 100-W WB1A 8-30 is the larger WB1A boiler: 29 to 100 MBH natural gas input at 95.1% AFUE in the same 95 lb (43 kg) cabinet.

DiscontinuedHistorically in Canada

Key figures

Max input
100 MBH
Max CSA output
—
AFUE
95.1 %
Min input
29 MBH
Natural gasHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Viessmann Vitodens 100-W WB1A 8-30 in practice

The WB1A 8-30 raises the first-generation 100-W to 100 MBH: 29-100 MBH (8.5-29.3 kW) natural gas input, 26-90 MBH (7.6-26.4 kW) output and a 78 MBH Net I=B=R rating at 95.1% AFUE.

Weight, dimensions and water content match the WB1A 8-24 — 95 lb (43 kg), 400 x 340 x 700 mm and 0.82 USG — with the same 45 psig maximum operating pressure. Like the smaller model it is a heating-only boiler; domestic hot water is handled separately.

Best suited to

  • Owners of existing WB1A 8-30 units looking up printed ratings
  • Residential loads between the WB1A 8-24 and later 100-W generations
  • Documentation for the larger WB1A size

Applicability and support

Model number
WB1A 8-30
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.

Viessmann Vitodens 100-W WB1A 8-30 specifications
SpecificationValueNote
Input
CSA input, minimum (natural gas)29 MBH8.5 kW, per the technical data manual
CSA input, maximum (natural gas)100 MBH29.3 kW, per the technical data manual
Output
CSA output / DOE heating capacity26-90 MBH7.6-26.4 kW, based on 140°F / 120°F supply/return
Net I=B=R rating78 MBHBased on piping and pick-up allowance of 1.15.
Efficiency
Efficiency (AFUE)95.1 %95.1% AFUE on both WB1A models per the technical data manual.
Physical and connections
Weight95 lb43 kg
Overall width400 mm15.7 in
Overall depth340 mm13.4 in
Overall height700 mm27.6 in
Operating limits and other
FuelNatural gasThe WB1A technical data manual prints natural-gas ratings only; minimum supply pressure 4 in. w.c.
Boiler water content0.82 USG3.1 L.
Maximum operating pressure45 psig3 bar at 210°F (99°C).
Boiler heating supply / return¾ in. NPTMGas supply ¾ in. NPTF.

Frequently asked questions

What is the WB1A 8-30 rated at?

29-100 MBH (8.5-29.3 kW) natural gas input, 26-90 MBH (7.6-26.4 kW) output, a 78 MBH Net I=B=R rating and 95.1% AFUE.

How does the WB1A 8-30 differ from the WB1A 8-24?

Only the firing range: 29-100 vs 29-80 MBH input and 26-90 vs 26-72 MBH output, in the same 95 lb cabinet.

Is the WB1A 8-30 a combi boiler?

No. The WB1A generation is heating-only; the WB1B generation later added a CombiPLUS version with on-demand DHW.

Questions about the Viessmann Vitodens 100-W WB1A 8-30?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate