Weil-McLain GV90+4 vs GV90+5

Verdict in brief

The GV90+5 is the first GV90+ to move to the long 37-3/4" cabinet: input steps from 105 to 140 MBH and DOE heating capacity from 97 to 130 MBH at a slightly higher 91.4% AFUE, with water content up from 4.7 to 6.0 gallons.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Weil-McLain GV90+4 and Weil-McLain GV90+5
SpecificationWeil-McLain GV90+4Weil-McLain GV90+5
Input, maximum105 MBH140 MBH
DOE heating capacity97 MBH130 MBH
Net AHRI water rating84 MBH113 MBH
Efficiency (AFUE)91.2 %91.4 %
Weight353 lb423 lb
Boiler water content4.7 gal6 gal
Venting3" PVC, CPVC, polypropylene or stainless steel (Category IV); 3" pipe on all GV90+ sizes3" PVC, CPVC, polypropylene or stainless steel (Category IV); 3" pipe on all GV90+ sizes

What actually separates them

Both are Series 2 GV90+ units with the built-in low water cut-off, 3" venting to 100 ft, 1" NPT supply and return connections and 1/2" NPT gas. The +5 steps input from 105 to 140 MBH, DOE heating capacity from 97 to 130 MBH and the net AHRI rating from 84 to 113 MBH.

The +5 is also the first size in the longer 37-3/4" cabinet, holding 6.0 gallons against 4.7 and shipping at 423 lb against 353 lb — a meaningful footprint and handling difference for a basement mechanical room.

Efficiency is nearly flat across the step — 91.4% AFUE on the +5 against 91.2% on the +4 — so the decision is capacity and cabinet size, driven by the heat-loss calculation and the boiler room's dimensions.

CurrentSold in Canada
Input
Output (max)
97 MBH
AFUE
91.2 %

The GV90+4 steps the cast iron line to 105 MBH input and 97 MBH DOE heating capacity at 91.2% AFUE, keeping the 30-3/4" cabinet length with 4.7 gallons of boiler water.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
Output (max)
130 MBH
AFUE
91.4 %

The GV90+5 is the first of the long-cabinet GV90+ sizes: 140 MBH input, 130 MBH DOE heating capacity and a 113 MBH net AHRI rating at 91.4% AFUE, in a 37-3/4" unit.

Natural gasPropaneHeating-only

Frequently asked questions

How much bigger is the GV90+5?

Its cabinet runs 37-3/4" long against 30-3/4" on the +4, and it ships at 423 lb against 353 lb with 6.0 gallons of water.

What are the GV90+5's ratings?

140 MBH input, 130 MBH DOE heating capacity, 113 MBH net AHRI and 91.4% AFUE.

Do both models vent the same way?

Yes — 3" Category IV pipe to 100 ft, with 1" NPT supply and return connections.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.