Weil-McLain GV90+5
The GV90+5 is the first of the long-cabinet GV90+ sizes: 140 MBH input, 130 MBH DOE heating capacity and a 113 MBH net AHRI rating at 91.4% AFUE, in a 37-3/4" unit.
Key figures
- Max input
- 140 MBH
- Max CSA output
- 130 MBH
- AFUE
- 91.4 %
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Weil-McLain GV90+5 in practice
The GV90+5 fires at 140 MBH CSA input for 130 MBH of DOE heating capacity and a 113 MBH net AHRI rating at 91.4% AFUE. It is the first GV90+ size to grow the cabinet to 37-3/4", holding 6.0 gallons of boiler water and shipping at 423 lb.
Venting remains 3" Category IV pipe to 100 ft, and Series 2 features — the built-in low water cut-off, indicator-light control and dual-circulator arrangement — are unchanged. The boiler suits high-temperature emitters and pairs with an indirect water heater for domestic hot water.
Best suited to
- Larger homes with loads in the 110-140 MBH band
- High-temperature radiator and fan-coil systems at the 130 MBH output mark
- Mechanical rooms that can take the 37-3/4" cabinet and 423 lb unit
Applicability and support
- Model number
- GV90+5
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Weil-McLain. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, maximum | 140 MBH | CSA input (maximum). |
| Output | ||
| DOE heating capacity | 130 MBH | DOE heating capacity at maximum input; the manuals also call this CSA Output. |
| Net AHRI water rating | 113 MBH | Net AHRI rating per the boiler manual ratings table. |
| Efficiency | ||
| Efficiency (AFUE) | 91.4 % | 91.4% AFUE. |
| Domestic hot water | ||
| Domestic hot water | Heating-only boiler; domestic hot water via an indirect tank or separate appliance | |
| Venting and air | ||
| Venting | 3" PVC, CPVC, polypropylene or stainless steel (Category IV); 3" pipe on all GV90+ sizes | Canada: install per CAN/CSA B149.1 or B149.2 with a ULC S636-compliant vent kit. |
| Max. equivalent vent/air length | 100 ft (vent and air each) | |
| Physical and connections | ||
| Weight | 423 lb | Approx. shipping weight per the boiler manual and brochure. |
| Cabinet length | 37-3/4" | |
| Gas connection | 1/2" NPT | |
| Heating water connections | 1" NPT supply (male) and 1" NPT return (female) | Minimum recommended pipe 1-1/4". |
| Operating limits and other | ||
| Boiler water content | 6 gal | |
| Fuel | Natural gas or propane | Propane requires a conversion kit per the CA product page. |
Manuals
- GV90+ Series 2 Boiler Manual, 550-143-010/0324550-143-010/0324 · 2024-03
Alerts documented for this model
- POWER LED flashes once per second
- POWER LED 2 flashes
- POWER LED 3 flashes
- POWER LED 4 flashes
- POWER LED 5 flashes
- POWER LED 6 flashes
- POWER light flashing alone
- POWER and TSTAT/CIRC lights flashing
- POWER and PRESS SWITCH lights flashing
- POWER and FLAME lights flashing
- FLAME lights flashing
- Solid LWCO light
- LWCO light flashing alone
- TSTAT/CIRC light flashing alone
- LIMIT light flashing alone
- POWER and LIMIT lights flashing
Frequently asked questions
What are the GV90+5's ratings?
140 MBH input, 130 MBH DOE heating capacity, 113 MBH net AHRI and 91.4% AFUE.
Does the GV90+5 need a bigger room than the +3/+4?
Yes — its cabinet is 37-3/4" long versus 30-3/4" on the +3 and +4, and it weighs 423 lb shipping.
What is the minimum recommended pipe for the GV90+5?
1-1/4" per the brochure, with 1" NPT supply and return connections and a 1/2" NPT gas connection.
Questions about the Weil-McLain GV90+5?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Weil-McLain Canada — GV90+ · accessed September 7, 2026
- GV90+ Series 2 Boiler Manual 550-143-010/0324 · 550-143-010/0324 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.