Weil-McLain · GV90+

Weil-McLain GV90+5

The GV90+5 is the first of the long-cabinet GV90+ sizes: 140 MBH input, 130 MBH DOE heating capacity and a 113 MBH net AHRI rating at 91.4% AFUE, in a 37-3/4" unit.

CurrentSold in Canada

Key figures

Max input
140 MBH
Max CSA output
130 MBH
AFUE
91.4 %
Min input
—
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Weil-McLain GV90+5 in practice

The GV90+5 fires at 140 MBH CSA input for 130 MBH of DOE heating capacity and a 113 MBH net AHRI rating at 91.4% AFUE. It is the first GV90+ size to grow the cabinet to 37-3/4", holding 6.0 gallons of boiler water and shipping at 423 lb.

Venting remains 3" Category IV pipe to 100 ft, and Series 2 features — the built-in low water cut-off, indicator-light control and dual-circulator arrangement — are unchanged. The boiler suits high-temperature emitters and pairs with an indirect water heater for domestic hot water.

Best suited to

  • Larger homes with loads in the 110-140 MBH band
  • High-temperature radiator and fan-coil systems at the 130 MBH output mark
  • Mechanical rooms that can take the 37-3/4" cabinet and 423 lb unit

Applicability and support

Model number
GV90+5
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Weil-McLain. Units are shown with every value; notes flag conflicting sources or missing figures.

Weil-McLain GV90+5 specifications
SpecificationValueNote
Input
Input, maximum140 MBHCSA input (maximum).
Output
DOE heating capacity130 MBHDOE heating capacity at maximum input; the manuals also call this CSA Output.
Net AHRI water rating113 MBHNet AHRI rating per the boiler manual ratings table.
Efficiency
Efficiency (AFUE)91.4 %91.4% AFUE.
Domestic hot water
Domestic hot waterHeating-only boiler; domestic hot water via an indirect tank or separate appliance
Venting and air
Venting3" PVC, CPVC, polypropylene or stainless steel (Category IV); 3" pipe on all GV90+ sizesCanada: install per CAN/CSA B149.1 or B149.2 with a ULC S636-compliant vent kit.
Max. equivalent vent/air length100 ft (vent and air each)
Physical and connections
Weight423 lbApprox. shipping weight per the boiler manual and brochure.
Cabinet length37-3/4"
Gas connection1/2" NPT
Heating water connections1" NPT supply (male) and 1" NPT return (female)Minimum recommended pipe 1-1/4".
Operating limits and other
Boiler water content6 gal
FuelNatural gas or propanePropane requires a conversion kit per the CA product page.

Frequently asked questions

What are the GV90+5's ratings?

140 MBH input, 130 MBH DOE heating capacity, 113 MBH net AHRI and 91.4% AFUE.

Does the GV90+5 need a bigger room than the +3/+4?

Yes — its cabinet is 37-3/4" long versus 30-3/4" on the +3 and +4, and it weighs 423 lb shipping.

What is the minimum recommended pipe for the GV90+5?

1-1/4" per the brochure, with 1" NPT supply and return connections and a 1/2" NPT gas connection.

Questions about the Weil-McLain GV90+5?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate