Weil-McLain GV90+5 vs GV90+6

Verdict in brief

The GV90+6 tops the line at 175 MBH input and 161 MBH DOE heating capacity against the +5's 140/130 MBH — both in the 37-3/4" cabinet, with the +6 at 91.0% AFUE and a 464 lb shipping weight.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Weil-McLain GV90+5 and Weil-McLain GV90+6
SpecificationWeil-McLain GV90+5Weil-McLain GV90+6
Input, maximum140 MBH175 MBH
DOE heating capacity130 MBH161 MBH
Net AHRI water rating113 MBH140 MBH
Efficiency (AFUE)91.4 %91 %
Weight423 lb464 lb
Boiler water content6 gal6.9 gal
Venting3" PVC, CPVC, polypropylene or stainless steel (Category IV); 3" pipe on all GV90+ sizes3" PVC, CPVC, polypropylene or stainless steel (Category IV); 3" pipe on all GV90+ sizes

What actually separates them

Both boilers share the 37-3/4" Series 2 cabinet, 3" venting to 100 ft and 1" NPT supply and return connections with 1/2" NPT gas. The +6 steps input from 140 to 175 MBH, DOE heating capacity from 130 to 161 MBH and the net AHRI rating from 113 to 140 MBH.

Water content rises from 6.0 to 6.9 gallons and shipping weight from 423 to 464 lb — the +6 is the heaviest GV90+, so the floor and access route deserve planning. Its 91.0% AFUE is the lowest of the four ratings, all of which sit in the 91.0-91.9% band.

Both are heating-only cast iron boilers suited to high-temperature emitters like baseboard and radiators. The +6 earns its place when the calculated load approaches the +5's 130 MBH of output on a design day.

CurrentSold in Canada
Input
Output (max)
130 MBH
AFUE
91.4 %

The GV90+5 is the first of the long-cabinet GV90+ sizes: 140 MBH input, 130 MBH DOE heating capacity and a 113 MBH net AHRI rating at 91.4% AFUE, in a 37-3/4" unit.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
Output (max)
161 MBH
AFUE
91 %

The GV90+6 is the largest GV90+ at 175 MBH input and 161 MBH DOE heating capacity — 91.0% AFUE in the 37-3/4" cabinet with 6.9 gallons of boiler water.

Natural gasPropaneHeating-only

Frequently asked questions

What are the GV90+6's ratings?

175 MBH input, 161 MBH DOE heating capacity, 140 MBH net AHRI and 91.0% AFUE.

Is the GV90+6 much heavier than the +5?

Yes — 464 lb shipping against 423 lb, with water content up from 6.0 to 6.9 gallons, in the same 37-3/4" cabinet.

When is the +6 the right choice?

When the heat-loss calculation for a large home or light-commercial plant exceeds the +5's 130 MBH of DOE output.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate