Skip to content
Boilers.caby ROMA Heating & Cooling

Bosch Thermotechnology · Buderus G124X (Logano G124X II/SP)

Buderus G124X/32

The Buderus G124X/32 is a discontinued atmospheric cast-iron gas boiler rated 132.5 MBH input with 84.6% AFUE, 96 MBH net IBR rating and a 337 lb dry weight.

DiscontinuedHistorically in Canada

Key figures

Max input
132.5 MBH
Max CSA output
AFUE
84.6 %
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Buderus G124X/32 in practice

Best suited to

    Applicability and support

    Model number
    G124X/32
    Canadian availability
    historical
    Production status
    discontinued
    ROMA supplies
    Confirmed at consultation
    ROMA services
    Confirmed at consultation
    Warranty
    Not verified

    Where ROMA provides on-site service

    On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

    See all service areas

    Specifications

    Published specifications

    Values as published by Bosch Thermotechnology. Units are shown with every value; notes flag conflicting sources or missing figures.

    Buderus G124X/32 specifications
    SpecificationValueNote
    Input
    Input rate132.5 MBHBrochure performance data; the installation manual prints 74, 103 and 132.5 MBtu/hr output.
    Output
    DOE heating capacity110 MBH
    Net IBR rating96 MBH
    Efficiency
    Efficiency (AFUE)84.6 %Buderus G124X/G234X/G334X brochure.
    Venting and air
    Vent connection (B-Vent II)6"Atmospheric boiler with draft hood; optional vent damper.
    Physical and connections
    Dry weight337 lb
    Water content3.4 US gal
    Operating limits and other
    Gas connection1/2"
    Boiler supply and return1"
    FuelNatural gas or propanePropane conversion kit instructions are served from the Canadian manual library.

    Questions about the Buderus G124X/32?

    Describe what the boiler is doing and get a straight answer about the next step.

    On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

    Sources and verification

    Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

    CallEmailEstimate