Skip to content
Boilers.caby ROMA Heating & Cooling

Bosch Thermotechnology · Bosch Singular Combi

Bosch Singular 4000

The Bosch Singular 4000 is the smaller of the two Canadian Singular combis: 19,900 to 80,000 BTU/hr space-heating input with DHW input to 155,000 BTU/hr (the '155K BTU' model), 95.0% AFUE, 6.0 GPM DHW flow at a 45 °F rise and stainless steel heat exchangers.

CurrentSold in Canada

Key figures

Max input
80 MBH
Max CSA output
—
AFUE
95 %
Min input
19.9 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Bosch Singular 4000 in practice

The Singular 4000 is the entry of Bosch's current wall-hung combi line, and Bosch's CA product page introduces the range as two models — the 155K BTU and 199K BTU versions — where 155K is this unit's maximum DHW input of 155,000 BTU/hr. Space heating is modest by comparison at 19,900 to 80,000 BTU/hr input, so the 4000 is a strong match for a home whose heat-loss calculation stays low while the hot-water side covers typical draws.

The IOM specification table (Table 2) prints 95.0% AFUE for natural gas and propane, DHW flow of 6.0 GPM at a 45 °F rise (4.0 GPM at 67 °F), stainless steel primary and secondary heat exchangers, and Bosch's CA copy estimates the 4000 can run between two and three showers depending on incoming water temperature. The cabinet measures 18.1 x 27.6 x 11.6 in and the engineering submittal sheet states the models weigh 80 lbs.

Venting is 2" or 3" PVC, CPVC, polypropylene or special gas vent type BH to 60 ft (2") or 150 ft (3"), with 0" clearance to combustibles. The control shows the A2-through-EF code families of IOM Table 30 (section 17.2), and the IOM's error chart directs support calls to Bosch at 866-642-3198.

Best suited to

  • Homes whose heat-loss calculation fits under 80 MBH of heating input
  • Households wanting a 155,000 BTU/hr DHW side without a separate tank
  • Smaller dwellings where the 6.0 GPM (45 °F rise) hot-water rating is enough

Applicability and support

Model number
Singular 4000
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Bosch Thermotechnology. Units are shown with every value; notes flag conflicting sources or missing figures.

Bosch Singular 4000 specifications
SpecificationValueNote
Input
Space-heating input, minimum19.9 MBH19,900 BTU/hr minimum input for space heating and DHW.
Space-heating input, maximum80 MBH80,000 BTU/hr maximum space-heating input.
Efficiency
Efficiency (AFUE)95 %95.0% natural gas (95.0% propane), printed in the IOM specification table and the engineering submittal sheet.
Domestic hot water
DHW input, maximum155 MBH155,000 BTU/hr maximum DHW input — the model the CA page presents as the 155K BTU version.
DHW flow rate at 45 °F temperature rise6 gpm6.0 GPM (23 LPM) at a 45 °F (25 °C) rise.
DHW flow rate at 67 °F temperature rise4 gpm4.0 GPM (15 LPM) at a 67 °F (37 °C) rise.
Minimum flow rate (DHW)0.5 gpm0.5 GPM (2.0 LPM) per the IOM specification table.
Venting and air
Venting2" or 3" PVC, CPVC, polypropylene, or 2"/3" special gas vent type BH (Class II, A/B/C)Forced-draft direct vent; 0" clearance to combustibles. Canadian plastic venting must meet ULC S636 where required.
Maximum vent length, 2"60 ft60 ft (18.3 m).
Maximum vent length, 3"150 ft150 ft (45.7 m).
Physical and connections
Weight80 lbThe engineering submittal sheet (05.2021) states the Singular models weigh 80 lbs; the CA product page claims 'under 80 pounds'.
Dimensions (W x D x H)18.1" × 27.6" × 11.6" (460 × 700 × 295 mm), width × depth × heightSpecification table values; the dimension drawing in the same IOM adds vent-adapter callouts to 31.87 in across mounted adapters.
Heat exchanger materialsStainless steel (primary and secondary)Per the IOM specification table.
Water pressure12-30 psi hydronic / 15-150 psi DHWPer the IOM specification table.
Gas supply pressureNG 3.5-10.5 in. W.C.; propane 8-13 in. W.C.
Gas connection3/4" NPT
ConnectionsSpace-heating supply/return 1" NPT; cold-water inlet and hot-water outlet 3/4" NPT
Electrical
Power supply120 V AC, 60 Hz; uses less than 5 A
Operating limits and other
FuelNatural gas or propaneSeparate NG and LPG ratings in the manual; LPG requires the gas conversion kit included with the appliance.
Temperature rangeSpace heating 82-180 °F; DHW 86-140 °FPer the IOM specification table.

Frequently asked questions

What is the 155K BTU name based on?

The CA product page presents the Singular 4000 as the 155K BTU model, matching its maximum DHW input of 155,000 BTU/hr. Its maximum space-heating input is 80,000 BTU/hr.

How much hot water does the Singular 4000 deliver?

The IOM specification table prints 6.0 GPM at a 45 °F temperature rise and 4.0 GPM at a 67 °F rise. Bosch's CA copy says the 4000 can run between two and three showers, depending on inlet water temperature.

Is the Singular 4000 energy-efficient?

It is rated 95.0% AFUE on natural gas and propane, printed in the IOM specification table — the figure that backs Bosch's 95% AFUE marketing for the Singular line.

Questions about the Bosch Singular 4000?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate