Bosch Singular 4000 vs Singular 5200

Verdict in brief

The Singular 4000 and 5200 are the same 80 lb wall-hung combi cabinet at 95.0% AFUE with the same 19,900 BTU/hr minimum input and venting to 60 ft in 2" or 150 ft in 3". The 5200 raises the DHW side from 155,000 to 199,000 BTU/hr (7.7 GPM versus 6.0 GPM at a 45 °F rise) and the space-heating input from 80,000 to 140,000 BTU/hr — the 5200 is the '199K BTU' model of the pair.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Bosch Singular 4000 and Bosch Singular 5200
SpecificationBosch Singular 4000Bosch Singular 5200
Space-heating input, minimum19.9 MBH19.9 MBH
Space-heating input, maximum80 MBH140 MBH
DHW input, maximum155 MBH199 MBH
DHW flow rate at 45 °F temperature rise6 gpm7.7 gpm
DHW flow rate at 67 °F temperature rise4 gpm5.2 gpm
Efficiency (AFUE)95 %95 %
Weight80 lb80 lb
Maximum vent length, 2"60 ft60 ft
Maximum vent length, 3"150 ft150 ft

What actually separates them

Both models are physically the same appliance: an 80 lb (per the engineering submittal sheet) wall-hung combi at 18.1 x 27.6 x 11.6 in, rated 95.0% AFUE on natural gas and propane, with stainless steel primary and secondary heat exchangers, 12-30 psi hydronic pressure, 3/4" NPT gas and 1" NPT heating connections, and venting to 60 ft in 2" or 150 ft in 3".

The two published differences are the firing ranges: space-heating input rises from 19,900-80,000 BTU/hr on the 4000 to 19,900-140,000 BTU/hr on the 5200, and DHW input from 19,900-155,000 to 19,900-199,000 BTU/hr. The spec table's DHW flow figures follow: 6.0 GPM against 7.7 GPM at a 45 °F rise (4.0 against 5.2 GPM at 67 °F).

Bosch's CA product page sells the pair as the 155K BTU and 199K BTU models — DHW-input figures — and estimates the 4000 runs two to three showers while the 5200 runs three showers plus a dishwasher, depending on inlet temperature. The minimum fire is identical at 19,900 BTU/hr, so in a low-load home both track mild weather the same way; the 5200 earns its place through the heat-loss calculation and the household's hot-water demand.

Bosch Thermotechnology

Bosch Singular 4000

CurrentSold in Canada
Input
19.9–80 MBH
Output (max)
AFUE
95 %

The Bosch Singular 4000 is the smaller of the two Canadian Singular combis: 19,900 to 80,000 BTU/hr space-heating input with DHW input to 155,000 BTU/hr (the '155K BTU' model), 95.0% AFUE, 6.0 GPM DHW flow at a 45 °F rise and stainless steel heat exchangers.

Natural gasPropaneCombi

Bosch Thermotechnology

Bosch Singular 5200

CurrentSold in Canada
Input
19.9–140 MBH
Output (max)
AFUE
95 %

The Bosch Singular 5200 is the larger Canadian Singular combi: 19,900 to 140,000 BTU/hr space-heating input with DHW input to 199,000 BTU/hr (the '199K BTU' model), 95.0% AFUE, 7.7 GPM DHW flow at a 45 °F rise and up to 10:1 turndown.

Natural gasPropaneCombi

Frequently asked questions

Are the Singular 4000 and 5200 the same size?

Yes — same 18.1 x 27.6 x 11.6 in cabinet at about 80 lb, same 95.0% AFUE rating, same venting. The models differ only in firing range and DHW delivery.

How much more hot water does the 5200 produce?

7.7 GPM at a 45 °F rise against the 4000's 6.0 GPM (5.2 versus 4.0 GPM at 67 °F), per the IOM specification table.

Which Singular model should a home choose?

Size from the heat-loss calculation and hot-water draw pattern: the 4000 covers most homes under an 80 MBH heating load, while the 5200 serves larger loads and heavier simultaneous draws without a bigger cabinet.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.