The Bosch Singular 5200 is the larger Canadian Singular combi: 19,900 to 140,000 BTU/hr space-heating input with DHW input to 199,000 BTU/hr (the '199K BTU' model), 95.0% AFUE, 7.7 GPM DHW flow at a 45 °F rise and up to 10:1 turndown.

CurrentSold in Canada

Key figures

Max input
140 MBH
Max CSA output
AFUE
95 %
Min input
19.9 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Bosch Singular 5200 in practice

The Singular 5200 is the flagship of Bosch's current wall-hung combi line — the 199K BTU model of the CA product page, whose DHW side fires 19,900 to 199,000 BTU/hr while space heating runs 19,900 to 140,000 BTU/hr input. That minimum-to-maximum spread on the DHW side is the basis of the 'turndown ratio up to 10:1' claim in the condensing-boilers category copy.

The IOM specification table prints 7.7 GPM at a 45 °F rise (5.2 GPM at 67 °F) and 95.0% AFUE on both fuels, with stainless steel primary and secondary heat exchangers. Bosch's CA copy says the 5200 can run three showers plus a dishwasher, depending on inlet water temperature — the kind of claim to weigh against a household's actual simultaneous-draw pattern.

The 5200 shares the 18.1 x 27.6 x 11.6 in cabinet, 80 lb stated weight and 60 ft/150 ft venting limits of the 4000, and its control shows the same A2-through-EF code set of IOM Table 30. Bosch's published Singular warranty covers the heat exchanger for ten years with five-year component coverage and first-year labour.

Best suited to

  • Larger homes whose heat-loss calculation reaches into the 140 MBH input range
  • Households with heavy or simultaneous hot-water draws needing 7.7 GPM at a 45 °F rise
  • Projects wanting the top of the Singular line with 199,000 BTU/hr DHW input

Applicability and support

Model number
Singular 5200
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Bosch Thermotechnology. Units are shown with every value; notes flag conflicting sources or missing figures.

Bosch Singular 5200 specifications
SpecificationValueNote
Input
Space-heating input, minimum19.9 MBH19,900 BTU/hr minimum input for space heating and DHW.
Space-heating input, maximum140 MBH140,000 BTU/hr maximum space-heating input.
Efficiency
Efficiency (AFUE)95 %95.0% natural gas (95.0% propane), printed in the IOM specification table and the engineering submittal sheet.
Domestic hot water
DHW input, maximum199 MBH199,000 BTU/hr maximum DHW input — the model the CA page presents as the 199K BTU version; 19,900 to 199,000 BTU/hr is the 10:1 turndown behind the category-page claim.
DHW flow rate at 45 °F temperature rise7.7 gpm7.7 GPM (29 LPM) at a 45 °F (25 °C) rise.
DHW flow rate at 67 °F temperature rise5.2 gpm5.2 GPM (20 LPM) at a 67 °F (37 °C) rise.
Minimum flow rate (DHW)0.5 gpm0.5 GPM (2.0 LPM) per the IOM specification table.
Venting and air
Venting2" or 3" PVC, CPVC, polypropylene, or 2"/3" special gas vent type BH (Class II, A/B/C)Forced-draft direct vent; 0" clearance to combustibles. Canadian plastic venting must meet ULC S636 where required.
Maximum vent length, 2"60 ft60 ft (18.3 m).
Maximum vent length, 3"150 ft150 ft (45.7 m).
Physical and connections
Weight80 lbThe engineering submittal sheet (05.2021) states the Singular models weigh 80 lbs; the CA product page claims 'under 80 pounds'.
Dimensions (W x D x H)18.1" × 27.6" × 11.6" (460 × 700 × 295 mm), width × depth × heightSpecification table values; the dimension drawing in the same IOM adds vent-adapter callouts to 31.87 in across mounted adapters.
Heat exchanger materialsStainless steel (primary and secondary)Per the IOM specification table.
Water pressure12-30 psi hydronic / 15-150 psi DHWPer the IOM specification table.
Gas supply pressureNG 3.5-10.5 in. W.C.; propane 8-13 in. W.C.
Gas connection3/4" NPT
ConnectionsSpace-heating supply/return 1" NPT; cold-water inlet and hot-water outlet 3/4" NPT
Electrical
Power supply120 V AC, 60 Hz; uses less than 5 A
Operating limits and other
FuelNatural gas or propaneSeparate NG and LPG ratings in the manual; LPG requires the gas conversion kit included with the appliance.
Temperature rangeSpace heating 82-180 °F; DHW 86-140 °FPer the IOM specification table.

Frequently asked questions

What does 199K BTU mean on the Singular 5200?

It is the model's maximum DHW input: 199,000 BTU/hr. Space heating is separate and caps at 140,000 BTU/hr input, so the 199K figure is not a heating rating.

Is 7.7 GPM a heating or hot-water figure?

Hot water. The IOM prints 7.7 GPM of DHW flow at a 45 °F temperature rise (5.2 GPM at 67 °F); actual delivery depends on incoming water temperature and the draw pattern.

What is the Singular 5200's turndown?

The condensing-boilers category page claims turndown up to 10:1, which matches the 5200's 19,900 to 199,000 BTU/hr DHW input range. Boilers.ca quotes the claim as Bosch's own.

Questions about the Bosch Singular 5200?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate