Skip to content
Boilers.caby ROMA Heating & Cooling

Burnham · Alta

Burnham Alta ALTA-080

The Burnham Alta ALTA-080 is the smallest heating-only Alta: 8 to 80 MBH input at 95.0% AFUE with 75 MBH heating capacity and a 65 MBH net AHRI water rating, on the OneTouch-controlled wall-hung condensing chassis.

CurrentCanadian status unknown

Key figures

Max input
80 MBH
Max CSA output
—
AFUE
95 %
Min input
8 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Burnham Alta ALTA-080 in practice

The ALTA-080 opens the Alta line at an 8–80 MBH heating input with 75 MBH heating capacity and a 65 MBH net AHRI water rating at 95.0% AFUE, per the ratings table in the official Alta Product Data Sheet (5/26 print). It is a heating-only model — domestic hot water comes from a separate indirect tank — on the wall-hung condensing chassis with the OneTouch system that sets combustion automatically and provides sensor-less, rate-based reset.

The entry-level Alta weighs 71 lb with a 16.3 in boiler depth (dimension 'A'), vents in 2" CPVC/PVC or polypropylene and carries the 316L stainless steel heat exchanger (12-year limited warranty) with a Grundfos 26-99 circulator. Standard build ships set for natural gas with altitude capability to 10,100 ft on 'G00' suffix models; the 50 psi MAWP (ASME 'H') boiler ships with a 30 psi relief valve.

All installation, gas, combustion and venting work belongs with a licensed contractor, sized from a heat-loss calculation. Canadian buyers should confirm supply and CSA/code compliance for the specific model before purchase, since usboiler.net prints no Canadian availability statement.

Best suited to

  • Compact homes whose heat-loss calculation fits an 80 MBH input ceiling
  • Heating-only hydronic systems paired with a separate indirect tank or water heater
  • Buyers who want OneTouch self-commissioning and the lightest Alta (71 lb)

Applicability and support

Model number
ALTA-080
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Burnham. Units are shown with every value; notes flag conflicting sources or missing figures.

Burnham Alta ALTA-080 specifications
SpecificationValueNote
Input
Heating input, minimum8 MBHMinimum heating input per the Alta Product Data Sheet ratings table.
Heating input, maximum80 MBHMaximum heating input per the Alta Product Data Sheet ratings table.
Output
Heating capacity75 MBHHeating capacity per the Alta Product Data Sheet ratings table.
Net AHRI water rating65 MBHNet AHRI water ratings based on a piping and pickup allowance of 1.15, per the PDS ratings table.
Efficiency
Efficiency (AFUE)95 %95.0% AFUE printed for this model in the Alta Product Data Sheet ratings table.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterA primary/secondary manifold accessory kit (P/N 111884-01) is available for heating-only models; no integrated DHW.
Venting and air
VentingDirect vent, sealed combustion — 2" universal vent connection (CPVC/PVC or polypropylene)2" universal vent connection and 2" air intake per the PDS; horizontal 2-pipe, vertical 2-pipe, concentric and hybrid configurations, plus a polypropylene chimney chase option.
Vent size2 inVent size column of the PDS ratings table prints 2 in for every Alta model.
Physical and connections
Boiler weight71 lbBoiler weight per the Alta Product Data Sheet ratings table.
Boiler depth16.3 inBoiler depth dimension 'A' per the PDS ratings and specifications table.
Gas connection1/2" NPT1/2" NPT gas connection as printed on the PDS connection figure.
Electrical
Electrical120 VAC connection board120 VAC connection board and separate low-voltage connection board per the PDS exploded view.
Operating limits and other
FuelNatural gas or propaneShips set for natural gas; two-step LP conversion at the gas valve switch and display — no kit purchase required, per the Alta Product Data Sheet.
ControlsOneTouch system — automatic combustion management, sensor-less rate-based reset, built-in self diagnostics, warm weather shutdownAutomatically sets combustion at start-up and continuously optimizes; outdoor-reset performance without an outdoor sensor. Not a Sage controller (verified in batch8 research).
Heat exchanger316L stainless steel heat exchanger, corrosion resistantWorld-leading 316L stainless steel per the PDS standard-equipment list; 12-year limited warranty per the product page.
Minimum gas supply pressure2.5 in. w.c. NG / 8.0 in. w.c. LPLow gas pressure capability as printed on the PDS standard-equipment list.
Maximum allowable working pressure (MAWP)50 psiSafety relief valve pressure, water: 30 PSI standard, ASME certified 'H'; maximum allowable working pressure 50 PSI, per the PDS.
Safety relief valve30 psi30 PSI standard per the PDS ratings and specifications notes.
Maximum allowable temperature setting210 °FMaximum allowable temperature setting 210°F; target setpoint 180°F; manual reset high limit setpoint 210°F, per the PDS.
Altitude rating10,100 ftAltitude capability to 10,100 ft on 'G00' suffix models (installed and set for altitude), per the PDS.
CirculatorGrundfos 26-99Grundfos 26-99 circulator on heating-only models, per the PDS.

Frequently asked questions

What are the ALTA-080's ratings?

8–80 MBH heating input, 75 MBH heating capacity, a 65 MBH net AHRI water rating and 95.0% AFUE, per the Alta Product Data Sheet ratings table.

Is the ALTA-080 a combi?

No — the ALTA-080 is heating-only. The combi models are the ALTAC-136B and ALTAC-200.

What venting does the ALTA-080 use?

A 2" universal vent connection for CPVC/PVC or polypropylene in a sealed-combustion direct-vent configuration, per the PDS.

Questions about the Burnham Alta ALTA-080?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate