The Alta is Burnham's wall-hung condensing boiler line from U.S. Boiler Company: OneTouch combustion management, a 316L stainless steel heat exchanger, combi (ALTAC) and heating-only (ALTA) models from 8 to 200 MBH input, all printing 95.0% AFUE in the official Alta Product Data Sheet.

Current seriesunknownNatural gasPropaneresidential

Series facts

Type
condensing
Efficiency
95% AFUE
Fuel
Natural gas or propane: boilers ship set for natural gas and convert to LP with a two-step conversion at the gas valve switch and display — no kit purchase required, per the Alta Product Data Sheet.
Venting
Direct vent, sealed combustion with a 2" universal vent connection for CPVC/PVC and polypropylene (2" air intake); horizontal 2-pipe, vertical 2-pipe, concentric and hybrid/concentric configurations, plus a polypropylene chimney chase option, per the Alta Product Data Sheet.
Models documented
6

95.0% AFUE printed for every model in the Alta Product Data Sheet ratings table (ALTAC-136B, ALTAC-200, ALTA-080, ALTA-120B, ALTA-150, ALTA-180). Net AHRI water ratings are based on a piping and pickup allowance of 1.15.

About the Alta

The Alta ('ALTA — High Efficiency Condensing Gas Boiler. Stainless Steel Heat Exchanger, Combi & Heating Models Available!') is the current wall-hung condensing line of the Burnham brand, built and documented by U.S. Boiler Company. It is controlled by the OneTouch system — combustion is set automatically at start-up, with sensor-less, rate-based reset that provides outdoor-reset performance without an outdoor sensor, built-in self diagnostics, warm-weather shutdown, continuous self-optimization and a simple two-step LP conversion at the gas valve switch and display (no kits). U.S. Boiler confirms Alta does NOT use the Sage controllers found on K2/Aspen/Alpine.

Six models are documented in the official Alta Product Data Sheet ratings table (5/26 print), every one at 95.0% AFUE: combis ALTAC-136B (13.6–120 MBH heating input, 113 MBH heating capacity, 98 MBH net AHRI, 3.7/3.4 GPM DHW at 70°F/77°F rise, DHW input 13.6–136) and ALTAC-200 (20–150 heating input, 141/123 MBH, 5.2/4.7 GPM, DHW input 20–200); heating-only ALTA-080 (8–80), ALTA-120B (13.6–120), ALTA-150 (20–150) and ALTA-180 (20–180). All six vent in 2" (CPVC/PVC or polypropylene) and run a 316L stainless steel heat exchanger with altitude capability to 10,100 ft on 'G00' suffix builds.

Standard equipment per the PDS includes a 30 PSI standard safety relief valve with ASME 'H' certification (50 PSI MAWP, 210°F maximum temperature setting, 180°F target setpoint), a UL353 boiler flow safety switch, low gas pressure capability (min 2.5 in. w.c. natural gas / 8.0 in. w.c. LP), the wall-hanging kit with optional floor stand, and a Grundfos 26-99 circulator on heating-only models or a Grundfos UPS-78 Special on combi models. Boilers.ca documents all six Alta models at model level. No official Canadian-sales statement was found on the official pages, so canadianStatus stays 'unknown'; the Alta page posts no I&O/service manual (only the Product Data Sheet and accessory instructions), which is flagged in each model's editorial note.

Highlights

  • Current condensing line: six models at 95.0% AFUE — combis ALTAC-136B and ALTAC-200, heating-only ALTA-080, ALTA-120B, ALTA-150 and ALTA-180
  • OneTouch system: automatic combustion setup, sensor-less rate-based reset (outdoor reset without the outdoor sensor), simple LP conversion with no kits — NOT Sage-controlled
  • 316L stainless steel heat exchanger; 2" universal CPVC/PVC or polypropylene venting; altitude to 10,100 ft ('G00' suffix builds)
  • 5-year parts warranty with 12-year limited heat exchanger warranty
  • Model-level pages published on Boilers.ca: ALTA-080, ALTA-120B, ALTA-150, ALTA-180, ALTAC-136B, ALTAC-200

5-year parts warranty with a 12-year limited warranty on the heat exchanger, per the official Alta product page.

Models

Alta models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
8–80 MBH
Output (max)
AFUE
95 %

The Burnham Alta ALTA-080 is the smallest heating-only Alta: 8 to 80 MBH input at 95.0% AFUE with 75 MBH heating capacity and a 65 MBH net AHRI water rating, on the OneTouch-controlled wall-hung condensing chassis.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
13.6–120 MBH
Output (max)
AFUE
95 %

The Burnham Alta ALTA-120B fires 13.6 to 120 MBH heating input at 95.0% AFUE — 112 MBH heating capacity and a 97 MBH net AHRI water rating — in the compact 16.3 in-deep heating-only Alta chassis.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
20–150 MBH
Output (max)
AFUE
95 %

The Burnham Alta ALTA-150 covers the mid-range of the heating-only Alta line: 20 to 150 MBH input at 95.0% AFUE with 141 MBH heating capacity and a 123 MBH net AHRI rating, in the 20.4 in-deep chassis.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
20–180 MBH
Output (max)
AFUE
95 %

The Burnham Alta ALTA-180 is the top heating-only Alta: 20 to 180 MBH input at 95.0% AFUE with 169 MBH heating capacity and a 147 MBH net AHRI water rating, at 103 lb in the 20.4 in-deep chassis.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
13.6–120 MBH
Output (max)
AFUE
95 %

The Burnham Alta Combi ALTAC-136B is the entry combi Alta: 13.6–120 MBH heating input with DHW input to 136 MBH, 3.7 GPM at a 70°F rise, 113 MBH heating capacity and a 98 MBH net AHRI rating at 95.0% AFUE.

Natural gasPropaneCombi
CurrentCanadian status unknown
Input
20–150 MBH
Output (max)
AFUE
95 %

The Burnham Alta Combi ALTAC-200 is the flagship Alta: 20–150 MBH heating input with DHW input to 200 MBH, 5.2 GPM at a 70°F rise, 141 MBH heating capacity and a 123 MBH net AHRI rating at 95.0% AFUE.

Natural gasPropaneCombi

Compare models in this series

Comparison of Burnham Alta ALTA-080 and Burnham Alta ALTA-120B and Burnham Alta ALTA-150 and Burnham Alta ALTA-180 and Burnham Alta Combi ALTAC-136B and Burnham Alta Combi ALTAC-200
SpecificationBurnham Alta ALTA-080Burnham Alta ALTA-120BBurnham Alta ALTA-150Burnham Alta ALTA-180Burnham Alta Combi ALTAC-136BBurnham Alta Combi ALTAC-200
Heating input, minimum8 MBH13.6 MBH20 MBH20 MBH13.6 MBH20 MBH
Heating input, maximum80 MBH120 MBH150 MBH180 MBH120 MBH150 MBH
output-max
Efficiency (AFUE)95 %95 %95 %95 %95 %95 %
turndown
vent-max-3
vent-max-2
Boiler weight71 lb76 lb103 lb103 lb95 lb116 lb

Read the full comparison: Burnham Alta ALTA-080 vs ALTA-120B

Read the full comparison: Burnham Alta ALTA-120B vs ALTA-150

Read the full comparison: Burnham Alta ALTA-150 vs ALTA-180

Read the full comparison: Burnham Alta Combi ALTAC-136B vs ALTAC-200

Error codes and alerts

Alta alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Does the Burnham Alta use the Sage control?

No — verified in batch8 research. The Alta is controlled by the OneTouch combustion-management system with built-in self diagnostics and plain-language on-screen messages; the Sage2.2/Sage2.3 controllers appear only on the K2, Aspen and Alpine pages.

Is the Alta available in Canada?

No official Canadian-sales statement was found on the official Alta pages (usboiler.net prints no Canada-specific availability wording), so canadianStatus is recorded as 'unknown' — Boilers.ca documents the series and its models for information and service planning.

Which Alta models are combis?

The two 'C' models — ALTAC-136B and ALTAC-200 — integrate a flat-plate DHW heat exchanger with a 3-way valve and Alta FastPipe primary/secondary piping included; the ALTA-080/120B/150/180 are heating-only with a manifold accessory kit available.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate