Skip to content
Boilers.caby ROMA Heating & Cooling

Cleaver-Brooks · Series

Cleaver-Brooks ClearFire-V

The ClearFire-V (Model CFV) is Cleaver-Brooks' compact vertical gas-fired steam boiler in nine sizes from 9.5 to 60 boiler horsepower, with AluFer tubes, a premix low-NOx burner, 150 psig design pressure and the Falcon touchscreen control.

unknownunknownNatural gascommercial

Series facts

Type
unknown
Efficiency
Unknown
Fuel
The ClearFire-V brochure describes a gas-fired premix burner; CB-8265 prints natural-gas inputs at rated capacity.
Venting
Unknown
Models documented
9
Warranty
Not verified

About the ClearFire-V

The ClearFire-V brochure (CB-8179) describes a compact gas-fired vertical boiler for commercial steam requirements, available in sizes from 9.5 to 60 boiler horsepower at 150 psig design pressure and 60 psig minimum operating pressure. It lists AluFer tubes, full burner modulation with variable-speed blower, single-phase 115 V power, direct spark ignition, low gas supply pressure under 14 in w.c., emissions under 20 ppm NOx and less than 10 ppm CO, and the Falcon touchscreen total boiler control.

Official drawing CB-8265 (Model CFV Vertical ClearFire, Dimensions and Ratings, 08-2012) prints the nine sizes — 9.5, 10, 15, 20, 25, 30, 40, 50 and 60 boiler horsepower — with steam capacities from 328 to 2,070 lb/hr from and at 212°F, outputs from 318 to 2,008 thousand BTU/hr, fireside heating surface, natural-gas inputs calculated at nominal 81% efficiency, connection sizes and blower motor ratings.

The ClearFire-V is a steam boiler and appears in Boilers.ca as commercial boiler context rather than a hydronic hub; the captured official material does not state discontinuation, so productStatus is recorded as unknown. The current Cleaver-Brooks condensing-hydronic catalogue lists the ClearFire-CE and SwitchFire rather than the CFV.

Highlights

  • Compact vertical gas-fired steam boiler, 9.5–60 boiler horsepower
  • Nine sizes: 9.5, 10, 15, 20, 25, 30, 40, 50, 60 HP
  • 328–2,070 lb/hr steam from and at 212°F; 318–2,008 MBH output
  • 150 psig design / 60 psig minimum operating pressure (brochure)
  • Under 20 ppm NOx and less than 10 ppm CO; premix burner
  • Falcon touchscreen control; single-phase 115 V power

Models

ClearFire-V models

One canonical page per model with input, output and efficiency kept separate.

Status unknownCanadian status unknown
Input
—
Output (max)
318,000 BTU/hr
AFUE
—

The Cleaver-Brooks ClearFire-V 9.5 HP is a vertical gas-fired steam boiler rated 328 lb/hr steam from and at 212°F and 318 thousand BTU/hr output, with 65 sq ft of fireside heating surface per the official CB-8265 ratings.

Natural gasHeating-only
Status unknownCanadian status unknown
Input
—
Output (max)
335,000 BTU/hr
AFUE
—

The Cleaver-Brooks ClearFire-V 10 HP is a vertical gas-fired steam boiler rated 345 lb/hr steam from and at 212°F and 335 thousand BTU/hr output, with 65 sq ft of fireside heating surface per the official CB-8265 ratings.

Natural gasHeating-only
Status unknownCanadian status unknown
Input
—
Output (max)
502,000 BTU/hr
AFUE
—

The Cleaver-Brooks ClearFire-V 15 HP is a vertical gas-fired steam boiler rated 518 lb/hr steam from and at 212°F and 502 thousand BTU/hr output, with 84 sq ft of fireside heating surface per the official CB-8265 ratings.

Natural gasHeating-only
Status unknownCanadian status unknown
Input
—
Output (max)
669,000 BTU/hr
AFUE
—

The Cleaver-Brooks ClearFire-V 20 HP is a vertical gas-fired steam boiler rated 690 lb/hr steam from and at 212°F and 669 thousand BTU/hr output, with 128 sq ft of fireside heating surface per the official CB-8265 ratings.

Natural gasHeating-only
Status unknownCanadian status unknown
Input
—
Output (max)
837,000 BTU/hr
AFUE
—

The Cleaver-Brooks ClearFire-V 25 HP is a vertical gas-fired steam boiler rated 863 lb/hr steam from and at 212°F and 837 thousand BTU/hr output, with 159 sq ft of fireside heating surface per the official CB-8265 ratings.

Natural gasHeating-only
Status unknownCanadian status unknown
Input
—
Output (max)
1,004,000 BTU/hr
AFUE
—

The Cleaver-Brooks ClearFire-V 30 HP is a vertical gas-fired steam boiler rated 1,035 lb/hr steam from and at 212°F and 1,004 thousand BTU/hr output, with 165 sq ft of fireside heating surface per the official CB-8265 ratings.

Natural gasHeating-only
Status unknownCanadian status unknown
Input
—
Output (max)
1,339,000 BTU/hr
AFUE
—

The Cleaver-Brooks ClearFire-V 40 HP is a vertical gas-fired steam boiler rated 1,380 lb/hr steam from and at 212°F and 1,339 thousand BTU/hr output, with 258 sq ft of fireside heating surface per the official CB-8265 ratings.

Natural gasHeating-only
Status unknownCanadian status unknown
Input
—
Output (max)
1,674,000 BTU/hr
AFUE
—

The Cleaver-Brooks ClearFire-V 50 HP is a vertical gas-fired steam boiler rated 1,725 lb/hr steam from and at 212°F and 1,674 thousand BTU/hr output, with 312 sq ft of fireside heating surface per the official CB-8265 ratings.

Natural gasHeating-only
Status unknownCanadian status unknown
Input
—
Output (max)
2,008,000 BTU/hr
AFUE
—

The Cleaver-Brooks ClearFire-V 60 HP is a vertical gas-fired steam boiler rated 2,070 lb/hr steam from and at 212°F and 2,008 thousand BTU/hr output, with 388 sq ft of fireside heating surface per the official CB-8265 ratings.

Natural gasHeating-only

Compare models in this series

Comparison of Cleaver-Brooks ClearFire-V 9.5 HP and Cleaver-Brooks ClearFire-V 10 HP and Cleaver-Brooks ClearFire-V 15 HP and Cleaver-Brooks ClearFire-V 20 HP and Cleaver-Brooks ClearFire-V 25 HP and Cleaver-Brooks ClearFire-V 30 HP and Cleaver-Brooks ClearFire-V 40 HP and Cleaver-Brooks ClearFire-V 50 HP and Cleaver-Brooks ClearFire-V 60 HP
SpecificationCleaver-Brooks ClearFire-V 9.5 HPCleaver-Brooks ClearFire-V 10 HPCleaver-Brooks ClearFire-V 15 HPCleaver-Brooks ClearFire-V 20 HPCleaver-Brooks ClearFire-V 25 HPCleaver-Brooks ClearFire-V 30 HPCleaver-Brooks ClearFire-V 40 HPCleaver-Brooks ClearFire-V 50 HPCleaver-Brooks ClearFire-V 60 HP
input-min—————————
input-max—————————
Output318,000 BTU/hr335,000 BTU/hr502,000 BTU/hr669,000 BTU/hr837,000 BTU/hr1,004,000 BTU/hr1,339,000 BTU/hr1,674,000 BTU/hr2,008,000 BTU/hr
afue—————————
turndown—————————
vent-max-3—————————
vent-max-2—————————
weight—————————

Read the full comparison: Cleaver-Brooks ClearFire-V 9.5 HP vs ClearFire-V 10 HP →

Read the full comparison: Cleaver-Brooks ClearFire-V 15 HP vs ClearFire-V 20 HP →

Read the full comparison: Cleaver-Brooks ClearFire-V 30 HP vs ClearFire-V 40 HP →

Read the full comparison: Cleaver-Brooks ClearFire-V 50 HP vs ClearFire-V 60 HP →

Error codes and alerts

ClearFire-V alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the ClearFire-V a steam or hydronic boiler?

It is a steam boiler: CB-8265 rates it in pounds of steam per hour from and at 212°F and prints steam outlet, feedwater and blowdown connections.

What sizes did the ClearFire-V come in?

Nine sizes from 9.5 to 60 boiler horsepower: 9.5, 10, 15, 20, 25, 30, 40, 50 and 60 HP, per CB-8265.

Is the ClearFire-V still catalogued?

The current Cleaver-Brooks condensing-hydronic catalogue lists the ClearFire-CE and SwitchFire; the CFV is documented from its official archived ratings and brochure, and productStatus is recorded as unknown.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate