Cleaver-Brooks · Series

Cleaver-Brooks ClearFire-W

The ClearFire-W (Model CFW) is Cleaver-Brooks' compact vertically fired firetube hydronic boiler in seven sizes from CFW 400 to CFW 2400, with AluFer extended-surface tubes, a CB Falcon control and a nominal fuel-to-water efficiency of up to 88%.

unknownunknownNatural gascommercial

Series facts

Type
non-condensing
Efficiency
88% thermal-efficiency
Fuel
The Model CFW O&M manual states the boiler is designed to fire natural gas.
Venting
Unknown
Models documented
7
Warranty
Not verified

Model CFW O&M manual: 'a nominal fuel-to-water efficiency of up to 88% depending on operating conditions.'

About the ClearFire-W

The Model CFW O&M manual (750-296, 06/2010) describes the ClearFire-W as a compact vertically fired firetube boiler with AluFer extended-surface tubes in a single-pass design, designed to fire natural gas, with a nominal fuel-to-water efficiency of up to 88% depending on operating conditions. It is built to a 125 psig MAWP under the ASME low-pressure Section IV hot water code and operates below 112 psig.

The manual prints seven sizes — CFW 400, 500, 750, 1000, 1500, 2000 and 2400 — with water capacities from 43 to 244 gal (Table 4-1) and minimum gas pressures of 7 to 10 in w.c. against a 28 in w.c. maximum (Table 2-3). The line uses the CB Falcon hydronic boiler control with a touchscreen and Modbus communication.

The captured official O&M manual does not print per-model input/output ratings, and the CB-8290 Dimensions and Ratings PDF was not recoverable from the archived official site, so those figures are not recorded on Boilers.ca. The current Cleaver-Brooks catalogue lists the ClearFire-CE and SwitchFire rather than the CFW, so productStatus is recorded as unknown.

Highlights

  • Compact vertically fired firetube hydronic boiler with AluFer tubes
  • Seven sizes: CFW 400, 500, 750, 1000, 1500, 2000, 2400
  • Up to 88% nominal fuel-to-water efficiency (manual)
  • 125 psig MAWP, operating below 112 psig; natural gas
  • CB Falcon touchscreen control with Modbus
  • Water capacities 43–244 gal; minimum gas pressure 7–10 in w.c.

Models

ClearFire-W models

One canonical page per model with input, output and efficiency kept separate.

Status unknownCanadian status unknown
Input
Output (max)
AFUE

The Cleaver-Brooks ClearFire-W CFW 400 is a compact vertically fired firetube hydronic boiler documented by the official Model CFW O&M manual (750-296), with 43 gal water capacity and a 7 in w.c. minimum gas pressure.

Natural gasHeating-only
Status unknownCanadian status unknown
Input
Output (max)
AFUE

The Cleaver-Brooks ClearFire-W CFW 500 is a compact vertically fired firetube hydronic boiler documented by the official Model CFW O&M manual (750-296), with 93 gal water capacity and a 7 in w.c. minimum gas pressure.

Natural gasHeating-only
Status unknownCanadian status unknown
Input
Output (max)
AFUE

The Cleaver-Brooks ClearFire-W CFW 750 is a compact vertically fired firetube hydronic boiler documented by the official Model CFW O&M manual (750-296), with 143 gal water capacity and a 7 in w.c. minimum gas pressure.

Natural gasHeating-only
Status unknownCanadian status unknown
Input
Output (max)
AFUE

The Cleaver-Brooks ClearFire-W CFW 1000 is a compact vertically fired firetube hydronic boiler documented by the official Model CFW O&M manual (750-296), with 164 gal water capacity and a 7 in w.c. minimum gas pressure.

Natural gasHeating-only
Status unknownCanadian status unknown
Input
Output (max)
AFUE

The Cleaver-Brooks ClearFire-W CFW 1500 is a compact vertically fired firetube hydronic boiler documented by the official Model CFW O&M manual (750-296), with 176 gal water capacity and a 10 in w.c. minimum gas pressure.

Natural gasHeating-only
Status unknownCanadian status unknown
Input
Output (max)
AFUE

The Cleaver-Brooks ClearFire-W CFW 2000 is a compact vertically fired firetube hydronic boiler documented by the official Model CFW O&M manual (750-296), with 211 gal water capacity and a 10 in w.c. minimum gas pressure.

Natural gasHeating-only
Status unknownCanadian status unknown
Input
Output (max)
AFUE

The Cleaver-Brooks ClearFire-W CFW 2400 is a compact vertically fired firetube hydronic boiler documented by the official Model CFW O&M manual (750-296), with 244 gal water capacity and a 10 in w.c. minimum gas pressure.

Natural gasHeating-only

Compare models in this series

Comparison of Cleaver-Brooks ClearFire-W CFW 400 and Cleaver-Brooks ClearFire-W CFW 500 and Cleaver-Brooks ClearFire-W CFW 750 and Cleaver-Brooks ClearFire-W CFW 1000 and Cleaver-Brooks ClearFire-W CFW 1500 and Cleaver-Brooks ClearFire-W CFW 2000 and Cleaver-Brooks ClearFire-W CFW 2400
SpecificationCleaver-Brooks ClearFire-W CFW 400Cleaver-Brooks ClearFire-W CFW 500Cleaver-Brooks ClearFire-W CFW 750Cleaver-Brooks ClearFire-W CFW 1000Cleaver-Brooks ClearFire-W CFW 1500Cleaver-Brooks ClearFire-W CFW 2000Cleaver-Brooks ClearFire-W CFW 2400
input-min
input-max
output-max
afue
turndown
vent-max-3
vent-max-2
weight

Read the full comparison: Cleaver-Brooks ClearFire-W CFW 400 vs ClearFire-W CFW 500

Read the full comparison: Cleaver-Brooks ClearFire-W CFW 1000 vs ClearFire-W CFW 1500

Read the full comparison: Cleaver-Brooks ClearFire-W CFW 1500 vs ClearFire-W CFW 2000

Read the full comparison: Cleaver-Brooks ClearFire-W CFW 2000 vs ClearFire-W CFW 2400

Error codes and alerts

ClearFire-W alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What sizes did the ClearFire-W come in?

Seven sizes: CFW 400, 500, 750, 1000, 1500, 2000 and 2400, per the official Model CFW O&M manual (750-296).

Is the ClearFire-W condensing?

The captured official Model CFW O&M manual describes a compact firetube hydronic boiler with up to 88% nominal fuel-to-water efficiency and does not label it fully condensing, so Boilers.ca records it as non-condensing with that wording.

Why are ratings missing from the CFW models?

The official O&M manual prints water capacity and gas-pressure tables but no per-model input/output ratings, and the CB-8290 Dimensions and Ratings PDF was not recoverable from the archived official site, so Boilers.ca does not publish unverified figures.