Crown Aruba 4 AWR280E

The Crown Aruba 4 AWR280E is the largest legacy AWR boiler: a fixed 280 MBH input for 234 MBH DOE heating capacity and a 203 MBH net AHRI rating at 83.3% AFUE across 9 cast-iron sections, with an 8" flue connector.

DiscontinuedCanadian status unknown

Key figures

Max input
280 MBH
Max CSA output
AFUE
83.3 %
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Crown Aruba 4 AWR280E in practice

The AWR280E tops the Aruba 4 range at a fixed 280 MBH input with 234 MBH DOE heating capacity and a 203 MBH net AHRI water rating at 83.3% AFUE, over 9 cast-iron sections (Table 2.2, manual P/N 9902339, May 2018). It is a NON-condensing, Category I natural-draft boiler with the draft hood built in, mandatory vent damper, and an 8" flue connector (C) into a lined masonry or listed metal chimney.

Supply/return tappings are 1-1/4" (side-relocatable) with the gas connection per the manifold and a required sediment trap; Honeywell S9361A interrupted ignition with EnviraCOM options listed. Dimension A is 30-3/4" — the widest jacket in the line — with dimension B 33-1/2", and like the 245E it carries the alcove front-clearance rating. Above 2,000 ft different main burner orifices apply; NG/LP suffix codes (AWR280EN / AWR280EL) complete the model.

Aruba 4 is legacy — the current catalogue lists Aruba 6 (AWR038C–AWR280C, 84.0% AFUE) — so productStatus is 'discontinued'; canadianStatus stays 'unknown'. A licensed contractor performs installation, gas and venting work.

Best suited to

  • The largest chimney-vented loads within a fixed 280 MBH AWR input
  • Owners documenting the flagship of the legacy Aruba 4 generation
  • Contractors comparing the Aruba 4 AWR280E with the current Aruba 6 AWR280C

Applicability and support

Model number
AWR280E
Canadian availability
unknown
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Crown Boiler Co.. Units are shown with every value; notes flag conflicting sources or missing figures.

Crown Aruba 4 AWR280E specifications
SpecificationValueNote
Input
Input280 MBHFixed input (no modulation) per the AWR space-heating ratings table (Table 2.2); NG/LP suffix added to the model (e.g. AWR210EN / AWR210EL).
Output
DOE heating capacity234 MBHHeating capacity per the AWR ratings table (Table 2.2).
Net AHRI water rating203 MBHNet AHRI water rating based on a piping and pickup allowance of 1.15 per the ratings table.
Efficiency
Efficiency (AFUE)83.3 %AFUE per the AWR ratings table (Table 2.2).
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
VentingCategory I natural draft — draft hood built into the boiler; lined masonry or listed metal chimneyVent damper installation is mandatory on all AWR boilers; flue connector size (C) 8" per the ratings table. Boilers above 2,000 ft need different main burner orifices.
Physical and connections
Cast-iron sections9Number of sections per the AWR ratings table.
Dimensions (A × B)30-3/4" × 33-1/2"Dimension A and dimension B per the AWR ratings table (Table 2.2); flue connector (C) is 8".
Supply/return tappings1-1/4"Supply and return tappings 1-1/4" (side-relocatable) per the installation manual.
Operating limits and other
Ignition and controlsHoneywell S9361A interrupted ignition with vent damperEnviraCOM options listed in the installation manual; the control shows discrete Err codes.
FuelNatural gas or propaneAdd suffix N for natural gas or L for propane to the basic boiler model (e.g. AWR210EN, AWR210EL).

Frequently asked questions

What are the AWR280E's ratings?

280 MBH fixed input, 234 MBH DOE heating capacity, a 203 MBH net AHRI water rating and 83.3% AFUE per the AWR ratings table.

How does the AWR280E differ from the AWR245E?

Input rises from 245 to 280 MBH, sections from 8 to 9, DOE capacity from 205 to 234 MBH and net AHRI from 178 to 203 MBH; dimension A grows from 27-5/8" to 30-3/4", the widest jacket in the line.

What replaced the Aruba 4?

The current Aruba 6 line (AWR038C–AWR280C) at 84.0% AFUE with left-side standard piping and a 5,400 ft standard altitude build, per the current product page.

Questions about the Crown Aruba 4 AWR280E?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate