Skip to content
Boilers.caby ROMA Heating & Cooling

Crown Boiler Co. · Series

Crown Boiler Co. Aruba 4

The Aruba 4 (AWR) is Crown's legacy cast-iron, NON-condensing natural-draft gas boiler: eight fixed-input sizes AWR038E through AWR280E (38–280 MBH) at 83.0–83.7% AFUE, discontinued in favour of the current Aruba 6 (AWR038C–AWR280C, 84.0% AFUE) and documented in the May 2018 installation manual (P/N 9902339).

discontinuedunknownNatural gasPropaneresidential

Series facts

Type
non-condensing
Efficiency
83.7% AFUE
Fuel
Natural gas or LP gas — model suffixes N (NG) and L (LP) follow the basic boiler model (e.g. AWR210EN / AWR210EL); installations above 2,000 ft need different main burner orifices.
Venting
Category I natural draft into a lined masonry or listed metal chimney — the draft hood is built into the boiler; vent damper installation is mandatory on all AWR models.
Models documented
8
Warranty
Not verified

Up to 83.7% AFUE (AWR105E); the AWR ratings table (Table 2.2) prints per-model AFUE of 83.0–83.7% across AWR038E–AWR280E.

About the Aruba 4

The Aruba 4 is Crown's cast-iron, gas-fired, natural-draft hot water boiler line — a NON-condensing design with the draft hood built into the boiler, vented as Category I into a lined masonry or listed metal chimney, with vent damper installation mandatory on every AWR model. The May 2018 AWR installation manual (P/N 9902339) covers eight fixed-input sizes from AWR038E to AWR280E (38, 70, 105, 140, 175, 210, 245 and 280 MBH) at AFUE ratings of 83.0–83.7%, with NG or LP suffix codes (e.g. AWR210EN/AWR210EL) and different main burner orifices required above 2,000 ft.

The AWR boiler is built for closed forced-circulation heating systems: supply/return tappings are 1-1/4" (side-relocatable), gas connection follows the manifold with a sediment trap required, ignition is Honeywell S9361A interrupted ignition with the vent damper, and EnviraCOM options are listed in the manual. Sections run 2–9 by model, with jacket dimension A from 9-3/4" to 30-3/4", dimension B 31-1/2"–33-1/2", and flue connector C from 4" to 8".

Aruba 4 is no longer in the current nav: the 2026 Velocity Boiler Works catalogue (crownboiler.com redirects to velocityboilerworks.com) lists the current line as Aruba 6 (AWR038C–AWR280C, 84.0% AFUE, left-side standard piping and a 5,400 ft standard altitude build), so Boilers.ca records the Aruba 4 as discontinued/legacy with productStatus 'discontinued'. Boilers.ca documents the AWR038E–AWR280E models at model level; no official Canadian-sales statement was found, so canadianStatus stays 'unknown', and installation work belongs with a licensed contractor.

Highlights

  • Legacy Crown cast-iron line — NON-condensing, Category I natural draft with built-in draft hood
  • Eight fixed-input sizes AWR038E–AWR280E (38–280 MBH) at 83.0–83.7% AFUE
  • Mandatory vent damper; Honeywell S9361A interrupted ignition with EnviraCOM options
  • NG or LP suffix codes (AWR210EN/EL style); different main burner orifices above 2,000 ft
  • Superseded by current Aruba 6 (AWR038C–AWR280C, 84.0% AFUE); docs live at crownboiler.com/pdfs/Aruba_4/
  • Model-level pages published on Boilers.ca; May 2018 manual (P/N 9902339) linked here

Models

Aruba 4 models

One canonical page per model with input, output and efficiency kept separate.

Crown Boiler Co.

Crown Aruba 4 AWR038E

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
83 %

The Crown Aruba 4 AWR038E is the smallest legacy AWR cast-iron boiler: a fixed 38 MBH input for 32 MBH DOE heating capacity and a 28 MBH net AHRI rating at 83.0% AFUE, Category I natural draft with a mandatory vent damper.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Aruba 4 AWR070E

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
83.5 %

The Crown Aruba 4 AWR070E fires a fixed 70 MBH for 58 MBH DOE heating capacity and a 50 MBH net AHRI rating at 83.5% AFUE across 3 cast-iron sections — the second size of the legacy Category I AWR line.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Aruba 4 AWR105E

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
83.7 %

The Crown Aruba 4 AWR105E fires a fixed 105 MBH for 87 MBH DOE heating capacity and a 76 MBH net AHRI rating at the line's highest 83.7% AFUE across 4 cast-iron sections, with a 5" flue connector.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Aruba 4 AWR140E

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
83.6 %

The Crown Aruba 4 AWR140E fires a fixed 140 MBH for 117 MBH DOE heating capacity and a 102 MBH net AHRI rating at 83.6% AFUE across 5 cast-iron sections, stepping to a 6" flue connector.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Aruba 4 AWR175E

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
83.5 %

The Crown Aruba 4 AWR175E fires a fixed 175 MBH for 146 MBH DOE heating capacity and a 127 MBH net AHRI rating at 83.5% AFUE across 6 cast-iron sections, with a 7" flue connector.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Aruba 4 AWR210E

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
83.4 %

The Crown Aruba 4 AWR210E fires a fixed 210 MBH for 175 MBH DOE heating capacity and a 152 MBH net AHRI rating at 83.4% AFUE across 7 cast-iron sections, with a 7" flue connector and the taller 33-1/2" dimension B.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Aruba 4 AWR245E

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
83.4 %

The Crown Aruba 4 AWR245E fires a fixed 245 MBH for 205 MBH DOE heating capacity and a 178 MBH net AHRI rating at 83.4% AFUE across 8 cast-iron sections, with the 8" flue connector and alcove clearance group.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Aruba 4 AWR280E

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
83.3 %

The Crown Aruba 4 AWR280E is the largest legacy AWR boiler: a fixed 280 MBH input for 234 MBH DOE heating capacity and a 203 MBH net AHRI rating at 83.3% AFUE across 9 cast-iron sections, with an 8" flue connector.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Crown Aruba 4 AWR038E and Crown Aruba 4 AWR070E and Crown Aruba 4 AWR105E and Crown Aruba 4 AWR140E and Crown Aruba 4 AWR175E and Crown Aruba 4 AWR210E and Crown Aruba 4 AWR245E and Crown Aruba 4 AWR280E
SpecificationCrown Aruba 4 AWR038ECrown Aruba 4 AWR070ECrown Aruba 4 AWR105ECrown Aruba 4 AWR140ECrown Aruba 4 AWR175ECrown Aruba 4 AWR210ECrown Aruba 4 AWR245ECrown Aruba 4 AWR280E
input-min————————
Input38 MBH70 MBH105 MBH140 MBH175 MBH210 MBH245 MBH280 MBH
output-max————————
Efficiency (AFUE)83 %83.5 %83.7 %83.6 %83.5 %83.4 %83.4 %83.3 %
turndown————————
vent-max-3————————
vent-max-2————————
weight————————

Read the full comparison: Crown Aruba 4 AWR070E vs AWR105E →

Read the full comparison: Crown Aruba 4 AWR140E vs AWR175E →

Read the full comparison: Crown Aruba 4 AWR210E vs AWR245E →

Read the full comparison: Crown Aruba 4 AWR038E vs AWR070E →

Error codes and alerts

Aruba 4 alerts

  • 4Aruba control (Err codes)
  • 6Aruba control (Err codes)
  • 18Aruba control (Err codes)
  • 23Aruba control (Err codes)
  • 32Aruba control (Err codes)
  • 35Aruba control (Err codes)
  • 55Aruba control (Err codes)
  • 56Aruba control (Err codes)
  • 57Aruba control (Err codes)
  • 58Aruba control (Err codes)
  • 59Aruba control (Err codes)
  • 60Aruba control (Err codes)
  • 61Aruba control (Err codes)
  • 63Aruba control (Err codes)
  • 64Aruba control (Err codes)
  • 89Aruba control (Err codes)

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the Aruba 4 still sold?

No. The 2026 catalogue lists the current line as Aruba 6 (AWR038C–AWR280C); the Aruba 4 (AWR038E–AWR280E) is legacy, with its manual still hosted at crownboiler.com/pdfs/Aruba_4/.

Is the Aruba 4 a condensing boiler?

No. The AWR series is a cast-iron, Category I natural-draft boiler with the draft hood built in, a mandatory vent damper, and venting into a lined masonry or listed metal chimney.

What sizes does the Aruba 4 come in?

Eight fixed-input sizes: AWR038E, AWR070E, AWR105E, AWR140E, AWR175E, AWR210E, AWR245E and AWR280E (38–280 MBH), at 83.0–83.7% AFUE per the ratings table.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate