Crown Bermuda BSI069

The Crown Bermuda BSI069 is the smallest legacy Bermuda size of the legacy cast-iron gas steam line: 69 MBH input, 57 MBH heating capacity and a 43 MBH AHRI net steam rating (179 sq ft) at 82% AFUE, over 3 cast-iron sections with 5.1 gallons of boiler water.

DiscontinuedCanadian status unknown

Key figures

Max input
Max CSA output
AFUE
82 %
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Crown Bermuda BSI069 in practice

The Bermuda BSI069 is a legacy cast-iron, natural-draft gas steam boiler rated at 69 MBH input with 57 MBH heating capacity and an AHRI net steam rating of 43 MBH (179 sq ft) at 82% AFUE per the BSI Space Heating Ratings table in the hosted 980433 Rev 12 I&O manual. It is built on 3 cast-iron sections with 5.1 gallons of boiler water.

The boiler measures 12-3/4" wide × 28" deep × 40-7/16" high with a 4" vent connection and an approximate shipping weight of 350 lb. The BSI IOM's rating table is headed 'Natural and LP Gas' with footnote 1 restricting use to altitudes at or below 2,000 ft in either fuel; BSI241 and BSI276 are marked as available semi-packaged. The line appears only in the frozen crownboiler.com legacy navigation and is superseded by the current Bermuda 2 (BSIB), which the official page says 'has many of the same features as the existing Bermuda (BSI)'.

Boilers.ca documents this size at model level from the hosted legacy manual; productStatus is 'discontinued'. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'; installation, gas, combustion and venting work belongs with a licensed contractor.

Best suited to

  • Owners documenting an installed Bermuda (BSI) against the legacy ratings table (43 MBH net steam)
  • Service planning for legacy cast-iron natural-draft steam boilers
  • Replacement research comparing BSI sizes with the current Bermuda 2 (BSIB)

Applicability and support

Model number
BSI069
Canadian availability
unknown
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Crown Boiler Co.. Units are shown with every value; notes flag conflicting sources or missing figures.

Crown Bermuda BSI069 specifications
SpecificationValueNote
Input
Input69 MBHInput per the BSI Space Heating Ratings table on the official product page / in the IOM.
Output
DOE heating capacity57 MBHDOE heating capacity per the BSI Space Heating Ratings table.
AHRI net steam rating43 MBHAHRI net steam rating 43 MBH (179 sq ft) based on a piping and pickup allowance of 1.333.
Efficiency
Efficiency (AFUE)82 %AFUE per the BSI Space Heating Ratings table.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
Vent size4"Vent diameter per the specification table.
VentingNatural draft into an approved chimneyCast-iron natural-draft steam boiler with a built-in draft diverter; automatic vent damper included on the Bermuda 2 (lit sheet).
Physical and connections
Cast-iron sections3Number of cast-iron sections per the specification table.
Boiler water volume5.1 galBoiler water volume per the BSI specification table.
Dimensions (W × D × H)12-3/4" × 28" × 40-7/16"Width (A) × depth (B) × height (C) per the specification table; D is the vent connection dimension.
Approximate shipping weight350 lbApproximate shipping weight per the specification table.
Operating limits and other
FuelNatural gas or LP gasThe BSI rating table is headed 'Natural and LP Gas' with footnote 1 restricting use to altitudes at or below 2,000 ft in either fuel.

Frequently asked questions

What are the Bermuda BSI069's ratings?

69 MBH input, 57 MBH heating capacity and a 43 MBH AHRI net steam rating (179 sq ft) at 82% AFUE per the BSI Space Heating Ratings table.

Does the BSI069 need a chimney?

Yes — it is a natural-draft steam boiler ('BSI Series — Gas-Fired Natural Draft Steam Boilers' per the manual cover) for chimney venting; it is not a direct-vent or condensing design.

Is the Bermuda BSI069 still sold?

No — the Bermuda (BSI) appears only in the frozen crownboiler.com legacy navigation and is absent from the current Velocity Boiler Works catalogue (verified September 9, 2026); it is superseded by the Bermuda 2 (BSIB).

Questions about the Crown Bermuda BSI069?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate