Crown Boiler Co. · Series

Crown Boiler Co. Bermuda (legacy)

The Bermuda (BSI) is Crown's legacy cast-iron, natural-draft gas steam boiler — seven sizes BSI069 through BSI276 from 69 to 276 MBH input and 43 to 172 MBH AHRI net steam at 82.0–82.2% AFUE — documented only in the frozen crownboiler.com 'Residential Gas' navigation and the still-hosted BSI I&O manual, and superseded by the current Bermuda 2 (BSIB).

discontinuedunknownNatural gasPropaneresidential

Series facts

Type
non-condensing
Efficiency
82.2% AFUE
Fuel
The BSI IOM's rating table is headed 'Natural and LP Gas', with footnote 1 stating the boilers are not for use at altitudes above 2,000 ft in natural or LP gas.
Venting
Natural draft into a chimney: the IOM cover titles the line 'BSI Series — Gas-Fired Natural Draft Steam Boilers'; the boiler is fully packaged for chimney venting with steam trim.
Models documented
7
Warranty
Not verified

The BSI Space Heating Ratings table prints 82.0% AFUE on BSI069/103/138, 82.1% on BSI172/207 and 82.2% on BSI241/276.

About the Bermuda (legacy)

The Bermuda (BSI) is Crown's legacy cast-iron gas steam boiler, documented in the frozen crownboiler.com 'Residential Gas' navigation as 'Bermuda Series (BSI)' and absent from the current Velocity Boiler Works menu. The legacy product page is an official shell with no body copy — it lists the hosted documents (the 980433 Rev 12 BSI I&O manual and the 109547-02 users information manual) — so Boilers.ca records the line from the hosted manual, whose cover titles it 'BSI Series — Gas-Fired Natural Draft Steam Boilers'.

The BSI Space Heating Ratings table (Table 2.2) covers seven models — BSI069 (69 MBH input, 57 MBH heating capacity, 179 sq ft / 43 MBH AHRI net steam, 82.0% AFUE), BSI103 (103/85/267/64, 82.0%), BSI138 (138/113/354/85, 82.0%), BSI172 (172/142/446/107, 82.1%), BSI207 (207/171/533/128, 82.1%), BSI241 (241/199/621/149, 82.2%) and BSI276 (276/229/717/172, 82.2%) — headed 'Natural and LP Gas', with 3–9 cast-iron sections, water volumes of 5.1–13.5 gallons and dimensions of 12-3/4"–32-1/4" wide × 28" or 30" deep × 40-7/16" high. Footnote 1 restricts use to altitudes at or below 2,000 ft in natural or LP gas; BSI241 and BSI276 are marked as available semi-packaged.

The current Bermuda 2 page states the new model 'has many of the same features as the existing Bermuda (BSI)', which is how the official site connects the two generations. Boilers.ca records the legacy Bermuda as productStatus 'discontinued' and documents all seven sizes at model level from the hosted manual; no official Canadian-sales statement was found, so canadianStatus stays 'unknown', and gas, combustion and venting work belongs with a licensed contractor.

Highlights

  • Legacy Crown gas steam line: Bermuda (BSI), BSI069 to BSI276 (69–276 MBH input)
  • AHRI net steam 43–172 MBH (179–717 sq ft); 82.0–82.2% AFUE
  • Natural and LP gas per the IOM table; not for use above 2,000 ft in either fuel
  • Cast-iron, natural-draft steam boiler over 3–9 sections; water volume 5.1–13.5 gal
  • Superseded by the current Bermuda 2 (BSIB), which shares 'many of the same features'
  • Frozen crownboiler.com legacy page with hosted BSI I&O manual (980433 Rev 12, 1/24)
  • Model-level pages published on Boilers.ca from the hosted manual

Models

Bermuda (legacy) models

One canonical page per model with input, output and efficiency kept separate.

Crown Boiler Co.

Crown Bermuda BSI069

DiscontinuedCanadian status unknown
Input
Output (max)
AFUE
82 %

The Crown Bermuda BSI069 is the smallest legacy Bermuda size of the legacy cast-iron gas steam line: 69 MBH input, 57 MBH heating capacity and a 43 MBH AHRI net steam rating (179 sq ft) at 82% AFUE, over 3 cast-iron sections with 5.1 gallons of boiler water.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Bermuda BSI103

DiscontinuedCanadian status unknown
Input
Output (max)
AFUE
82 %

The Crown Bermuda BSI103 is a 103 MBH mid-small size of the legacy cast-iron gas steam line: 103 MBH input, 85 MBH heating capacity and a 64 MBH AHRI net steam rating (267 sq ft) at 82% AFUE, over 4 cast-iron sections with 6.5 gallons of boiler water.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Bermuda BSI138

DiscontinuedCanadian status unknown
Input
Output (max)
AFUE
82 %

The Crown Bermuda BSI138 is a 138 MBH mid size of the legacy cast-iron gas steam line: 138 MBH input, 113 MBH heating capacity and a 85 MBH AHRI net steam rating (354 sq ft) at 82% AFUE, over 5 cast-iron sections with 7.9 gallons of boiler water.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Bermuda BSI172

DiscontinuedCanadian status unknown
Input
Output (max)
AFUE
82.1 %

The Crown Bermuda BSI172 is a 172 MBH mid-large size of the legacy cast-iron gas steam line: 172 MBH input, 142 MBH heating capacity and a 107 MBH AHRI net steam rating (446 sq ft) at 82.1% AFUE, over 6 cast-iron sections with 9.3 gallons of boiler water.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Bermuda BSI207

DiscontinuedCanadian status unknown
Input
Output (max)
AFUE
82.1 %

The Crown Bermuda BSI207 is a 207 MBH large size of the legacy cast-iron gas steam line: 207 MBH input, 171 MBH heating capacity and a 128 MBH AHRI net steam rating (533 sq ft) at 82.1% AFUE, over 7 cast-iron sections with 10.7 gallons of boiler water.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Bermuda BSI241

DiscontinuedCanadian status unknown
Input
Output (max)
AFUE
82.2 %

The Crown Bermuda BSI241 is a 241 MBH large size (available semi-packaged) of the legacy cast-iron gas steam line: 241 MBH input, 199 MBH heating capacity and a 149 MBH AHRI net steam rating (621 sq ft) at 82.2% AFUE, over 8 cast-iron sections with 12.1 gallons of boiler water.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Bermuda BSI276

DiscontinuedCanadian status unknown
Input
Output (max)
AFUE
82.2 %

The Crown Bermuda BSI276 is the largest legacy Bermuda size (available semi-packaged) of the legacy cast-iron gas steam line: 276 MBH input, 229 MBH heating capacity and a 172 MBH AHRI net steam rating (717 sq ft) at 82.2% AFUE, over 9 cast-iron sections with 13.5 gallons of boiler water.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Crown Bermuda BSI069 and Crown Bermuda BSI103 and Crown Bermuda BSI138 and Crown Bermuda BSI172 and Crown Bermuda BSI207 and Crown Bermuda BSI241 and Crown Bermuda BSI276
SpecificationCrown Bermuda BSI069Crown Bermuda BSI103Crown Bermuda BSI138Crown Bermuda BSI172Crown Bermuda BSI207Crown Bermuda BSI241Crown Bermuda BSI276
input-min
input-max
output-max
Efficiency (AFUE)82 %82 %82 %82.1 %82.1 %82.2 %82.2 %
turndown
vent-max-3
vent-max-2
weight

Read the full comparison: Crown Bermuda BSI069 vs BSI103

Read the full comparison: Crown Bermuda BSI103 vs BSI138

Read the full comparison: Crown Bermuda BSI138 vs BSI172

Read the full comparison: Crown Bermuda BSI172 vs BSI207

Error codes and alerts

Bermuda (legacy) alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the Crown Bermuda (BSI) still sold?

No — the Bermuda (BSI) appears only in the frozen crownboiler.com legacy navigation and is absent from the current Velocity Boiler Works catalogue, so Boilers.ca records productStatus 'discontinued'. It is superseded by the current Bermuda 2 (BSIB).

What sizes did the Bermuda (BSI) come in?

Seven: BSI069, BSI103, BSI138, BSI172, BSI207, BSI241 and BSI276 at 69, 103, 138, 172, 207, 241 and 276 MBH input, with 43–172 MBH AHRI net steam ratings and 82.0–82.2% AFUE per the BSI Space Heating Ratings table.

How is the Bermuda (BSI) different from the Bermuda 2 (BSIB)?

They are consecutive generations of the same Crown cast-iron steam boiler line. The current Bermuda 2 (BSIB) page states it 'has many of the same features as the existing Bermuda (BSI)'; the legacy BSI used model numbers without the B suffix (BSI069 style) while the Bermuda 2 uses BSI069B-style numbers.