Crown Boiler Co. · Bermuda (legacy)
Crown Bermuda BSI103
The Crown Bermuda BSI103 is a 103 MBH mid-small size of the legacy cast-iron gas steam line: 103 MBH input, 85 MBH heating capacity and a 64 MBH AHRI net steam rating (267 sq ft) at 82% AFUE, over 4 cast-iron sections with 6.5 gallons of boiler water.
Key figures
- Max input
- —
- Max CSA output
- —
- AFUE
- 82 %
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Crown Bermuda BSI103 in practice
The Bermuda BSI103 is a legacy cast-iron, natural-draft gas steam boiler rated at 103 MBH input with 85 MBH heating capacity and an AHRI net steam rating of 64 MBH (267 sq ft) at 82% AFUE per the BSI Space Heating Ratings table in the hosted 980433 Rev 12 I&O manual. It is built on 4 cast-iron sections with 6.5 gallons of boiler water.
The boiler measures 16" wide × 28" deep × 40-7/16" high with a 5" vent connection and an approximate shipping weight of 420 lb. The BSI IOM's rating table is headed 'Natural and LP Gas' with footnote 1 restricting use to altitudes at or below 2,000 ft in either fuel; BSI241 and BSI276 are marked as available semi-packaged. The line appears only in the frozen crownboiler.com legacy navigation and is superseded by the current Bermuda 2 (BSIB), which the official page says 'has many of the same features as the existing Bermuda (BSI)'.
Boilers.ca documents this size at model level from the hosted legacy manual; productStatus is 'discontinued'. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'; installation, gas, combustion and venting work belongs with a licensed contractor.
Best suited to
- Owners documenting an installed Bermuda (BSI) against the legacy ratings table (64 MBH net steam)
- Service planning for legacy cast-iron natural-draft steam boilers
- Replacement research comparing BSI sizes with the current Bermuda 2 (BSIB)
Applicability and support
- Model number
- BSI103
- Canadian availability
- unknown
- Production status
- discontinued
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Crown Boiler Co.. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input | 103 MBH | Input per the BSI Space Heating Ratings table on the official product page / in the IOM. |
| Output | ||
| DOE heating capacity | 85 MBH | DOE heating capacity per the BSI Space Heating Ratings table. |
| AHRI net steam rating | 64 MBH | AHRI net steam rating 64 MBH (267 sq ft) based on a piping and pickup allowance of 1.333. |
| Efficiency | ||
| Efficiency (AFUE) | 82 % | AFUE per the BSI Space Heating Ratings table. |
| Domestic hot water | ||
| Domestic hot water | Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater | |
| Venting and air | ||
| Vent size | 5" | Vent diameter per the specification table. |
| Venting | Natural draft into an approved chimney | Cast-iron natural-draft steam boiler with a built-in draft diverter; automatic vent damper included on the Bermuda 2 (lit sheet). |
| Physical and connections | ||
| Cast-iron sections | 4 | Number of cast-iron sections per the specification table. |
| Boiler water volume | 6.5 gal | Boiler water volume per the BSI specification table. |
| Dimensions (W × D × H) | 16" × 28" × 40-7/16" | Width (A) × depth (B) × height (C) per the specification table; D is the vent connection dimension. |
| Approximate shipping weight | 420 lb | Approximate shipping weight per the specification table. |
| Operating limits and other | ||
| Fuel | Natural gas or LP gas | The BSI rating table is headed 'Natural and LP Gas' with footnote 1 restricting use to altitudes at or below 2,000 ft in either fuel. |
Manuals
Alerts documented for this model
None documented yet.
Frequently asked questions
What are the Bermuda BSI103's ratings?
103 MBH input, 85 MBH heating capacity and a 64 MBH AHRI net steam rating (267 sq ft) at 82% AFUE per the BSI Space Heating Ratings table.
Does the BSI103 need a chimney?
Yes — it is a natural-draft steam boiler ('BSI Series — Gas-Fired Natural Draft Steam Boilers' per the manual cover) for chimney venting; it is not a direct-vent or condensing design.
Is the Bermuda BSI103 still sold?
No — the Bermuda (BSI) appears only in the frozen crownboiler.com legacy navigation and is absent from the current Velocity Boiler Works catalogue (verified September 9, 2026); it is superseded by the Bermuda 2 (BSIB).
Questions about the Crown Bermuda BSI103?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- Crown Bermuda BSI069 vs BSI103Comparison
- Crown Bermuda BSI103 vs BSI138Comparison
- Crown Bermuda BSI069Same series
- Crown Bermuda BSI138Same series
- Crown Bermuda BSI172Same series
- Crown Bermuda BSI207Same series
- Crown Bermuda BSI241Same series
- Crown Bermuda BSI276Same series
- Bermuda (legacy) series hub
- Buying guide
Sources and verification
- crownboiler.com — Bermuda Series (BSI) legacy product page (frozen site) · accessed September 9, 2026
- BSI Series Gas-Fired Natural Draft Steam Boilers — Installation, Operating & Service Instructions, 980433 Rev 12 (1/24) (PDF) · 980433 Rev 12 · accessed September 9, 2026
- Cast Iron Gas-Fired Boilers Users Information Manual, 109547-02 (1/24) (PDF) · 109547-02 · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.